Check 1

Start

(1) Pull out Power Cord Plug and disconnect connectors CN10, CN41, CN42, CN49 and 

CN50 on Main Power PCB.

(2) Connect 1 to pin 2 and 3 to pin 4 on CN4 connector.
(3) Plug in Power Cord Plug and turn on power switch.

PDP faulty.

Power supply protector operated

Power lamp : Flashing continuously in red.

(at an interval of 1 sec)

(1) Pull out Power Cord Plug and disconnect connector CN351 and CN352 on Main Power PCB.
(2) Connect 1 to pin 13 on connector CN352.
(3) Disconnect connectors on Main Power PCB. (CN10, CN41, CN42, CN49, CN50)
(4) Plug in Power Cord Plug and turn on power switch.

(1) Pull out Power Cord Plug and connect connector CN351 and CN352 to Power Supply Unit.
(2) Remove Video PCB Assy.
(3) Plug in Power Cord Plug and turn on power switch.
(4) Check state of green lamp.

∗ 

Replace PDP.

∗ 

Vs and -Vy must be adjusted.

Yes

No

Does 

lamp change to

green?

Power Supply
circuit faulty.

Replace Main
Power PCB.

∗ 

Vs and -Vy must be adjusted.

No

Is voltage 

at each connector on 

Main Power PCB normal ? 

See page 19.

Video circuit
faulty.

Replace Video
PCB Assy.

Yes

Main/Digital
circuit faulty.

Replace Main
/Digital PCB Assy.

No

Is green lamp lit

continuously?

Summary of Contents for Plasmavision PDS4229W-B

Page 1: ...PDS4229W B Copy Prohibited FUJITSU GENERAL Proprietar y ...

Page 2: ...IGNALS 5 CONNECTION 7 PART NAMES AND FUNCTIONS 8 TROUBLESHOOTING USING LED AND OSD 12 VOLTAGE OF EACH CONNECTOR 19 VS AND VY ADJUSTMENT 20 GENERAL CONNECTION DIAGRAM 21 INSTALLATION 22 DISASSEMBLY FLOWCHART 29 PARTS LIST 43 TRANSPORTATION AND HANDLING RESTRICTIONS 44 ...

Page 3: ...sible injury to the operator When transporting by car place the unit as shown in the figure Slots and openings in the cabinet are provided for ventilation These ensure reliable operation and protect the unit from overheating These openings must not be blocked or covered The openings should never be blocked by placing the unit on a bed sofa rug or similar surface The unit should not be placed in a ...

Page 4: ...r or parts with the same characteristics as the original parts Unauthorized substitutions may result in fire electric shock or other hazards Upon completion of any service of repairs ask the service technician to perform safety checks to determine that the unit is in proper operating condition Place the unit more than one foot away from heat sources such as radiators heat registers stoves and othe...

Page 5: ...isplay colors 16 7 million 256 each for R G B Language English German French Italy Portuguese Spanish E type Russian Dimensions Width 103 5 cm 46 7 inch Height 64 0 cm 25 2 inch Depth 8 5 cm 5 9 inch Net weight 28 5kg Environment Operating Temperature 00 to 40 C Relative humidity 20 to 90 Pressure 800 to 1 114 hPa Accessories User s manual Remote controller Dry batteries Type AA 2pcs Power cable F...

Page 6: ... INPUT color difference input RGB INPUT To receptacle Connection to AV equipment Connection to PC To video output terminal To S video output terminal To display analog RGB output terminal To RS 232C output terminal To color difference output terminal 7 CONNECTION ...

Page 7: ...ll through options in a menu or to change values o Set button ENTER Press this button to finalize the selection of a desired option in a menu q Power ON button POWER ON Turns the power ON w Power OFF button POWER OFF Turns the power OFF e RGB input mode selector button RGB Switches between RGB input modes r Video input mode selector button VIDEO Switches between video input modes t Wide screen sel...

Page 8: ... terminal No RGB cable is supplied with the display The type of cable to be used varies depending on the PC model e Component video input terminal COMPONENT VIDEO INPUT Connect this terminal to the component video output color difference output terminal of your HDTV unit or DVD player When connecting a cable attach a ferrite core to the cable r S video input terminal S VIDEO INPUT Connect this ter...

Page 9: ...emperature of unit Main Digital PCB Temp sensor IC757 1 OSD LED lamp display status Cause Check point Steady light Red Stand by status Continuous Flashes continuously Red No power Power supply protector operated Main power PCB PFC PCB PDP panel 1 time Flashes once every 4 sec Red Fan protector operated Fan Main power PCB Main Digital PCB 2 times Flashes twice every 5 sec Red Temperature protector ...

Page 10: ...five times Power not turned off LED blinks only RED Replace Video PCB Assy Is on screen display normal Check 4 All input image faulty Signal processing PCB faulty Replace Main Digital PCB Assy Video input image faulty Check 5 S video input image faulty Check 5 Component video input image faulty Check 6 RGB input image faulty Check 7 Lights steadily for more than 10 sec GREEN NO YES Note 1 Since a ...

Page 11: ...Disconnect connectors on Main Power PCB CN10 CN41 CN42 CN49 CN50 4 Plug in Power Cord Plug and turn on power switch 1 Pull out Power Cord Plug and connect connector CN351 and CN352 to Power Supply Unit 2 Remove Video PCB Assy 3 Plug in Power Cord Plug and turn on power switch 4 Check state of green lamp Replace PDP Vs and Vy must be adjusted Yes No Does lamp change to green Power Supply circuit fa...

Page 12: ...es intermittently twice in red For 0 5 sec at an interval of 5 sec Check 3 Start Adjust PDP unit installation so that peripheral temperature is 40 0 C or less No Yes Is ambient temperature of IC757 on Main Digital PCB less than 60 C Microcomputer peripheral circuit faulty Yes Replace Main Digital PCB Assy Microcomputer peripheral circuit faulty Replace Main Digital PCB Assy Fan faulty Replace fan ...

Page 13: ...er PCB normal Power Supply circuit faulty Replace Main Power PCB Yes No Is picture displayed normally when PDP changed PDP panel faulty Replace PDP panel Signal processing circuit faulty Replace Main Digital PCB Assy Start Yes No No Can this unit select only RGB mode Install video PCB Assy firmly Yes Is picture displayed on screen normal when new video PCB unit installed Video PCB Assy faulty Repl...

Page 14: ...deo PCB Unit faulty Replace Video PCB Assy No Yes Are brightness and color difference signals connected to input terminals correctly Check connection cable Yes No Is signal input level normally Signal processing circuit faulty Replace Main Digital PCB Assy Check input signal SYNC signals are added to the Y signal Is picture displayed on screen normal when new video PCB Unit installed ...

Page 15: ...cable Is Sync signal TLL and polarity negative Is horizontal sync signal input to pin 3 and vertical sync signal input to pin 4 of RGB cable Check connection cable Check input signal Connect RGB cable to terminal Check input signal No Make sync signal polarity output from signal source negative or make output impedance TTL No Check input signal No Check input signal Is frequency of horizontal sync...

Page 16: ...ck LED turns off 1 Disconnect CN4 CN10 CN41 CN42 CN49 and CN50 2 Connect pins 1 and 2 3 and 4 of CN4 3 Press the power button 2 On the Main Power Supply PCB M00BV CN41 Ground No NAME SPEC 1 Vcc 1 5 0V 0 25V 2 9 Vs 180 0V 3 2V 5 CN50 Ground No NAME SPEC 3 Va 65 0V 1 3V 4 1 Vw 170 0V 5 0V 2 CN42 Ground No NAME SPEC 3 Vy 165 0V 3 0V 5 4 Vsc 120 0V 3 5V 3 CN10 Ground No NAME SPEC 3 Ve 16 0V 0 4V 4 CN3...

Page 17: ...tment points Refer to the drawing shown below Adjustment value Within 0 1V of voltage indicated on the label of the PDP panel NOTE After the power cord plug was pulled out do not pull out the connector on the Main Power PCB until the Green LED D531 Discharge check LED turns off T2 T3 T4 T5 VR582 Vs ADJ VR633 Vy ADJ CN352 CN351 CN41 CN42 CN49 CN50 L583 CN4 CN10 1 6 10 1 MAIN POWER SUPPLY PCB M00BV ...

Page 18: ... VH 6P 1 VCC1 GND VCC1 4 CN VH 2P 1 VCC1 GND VCC1 VA GND VA 4 CN8 VH 4P P1001 TX24 60P CN701 TX24 60P CN752 B5B PH SM3 TBT CN351 VH 10P L TYP CN401 M SUB 15PIN CN4500 FX28 68P CN352 B13B PH SM3 TBT CN751 B8B PH SM3 TBT SIGNAL PROCESSING P954 B3B PH SM3 TBT 3 14V FANPRM3 GND 1 P953 B3B PH SM3 TBT Y TYP SMT TX25 30P 12ST H1 CN702 CN1004 TX24 30R 6ST H1 CN1001 BNC P6900 P6701 KEY SWITCH LED PHOTO AMP...

Page 19: ...optical filter may peel off Wipe the surface of the optical filter with a soft lint free cloth such as cotton The surface of the optical filter scratches easily so do not rub or hit it with a hard object 7 The brightness and contrast of the PDP are still inferior to those of a CRT Also note that the ambient light may cause the screen become white and difficult to read Therefore it is recommended t...

Page 20: ...3 Grounding should be performed Ground connected to power outlet is acceptable 4 Sufficient passage space 5 Installation should be performed by at least two peoples A simple lifter should be used 6 When carrying the unpacked unit do not hold the Optical Filter 3 Outline Drawings Ceiling Floor 64 cm 42 Plasmavision Sufficient space is needed for people to pass or to move objects 94 5 103 5 54 4 64 ...

Page 21: ...ent the power and other cables from being accidentally pulled make sure that they run along the wall or through corners The display can be installed with either of its sides facing down 24 When using the stand cm cm 10 10 10 6 Left Right Upper Floor Wall 1 5 Floor Front Side When using the wall mounting unit Horizontal type cm cm 10 10 10 6 Left Right Upper Lower 1 5 Wall Wall mounting unit Front ...

Page 22: ...brackets at the same height as or slightly lower than the display brackets 3 Tie brackets A and B together To do this use strong cords to fasten the display securely to the wall Use the two screws supplied with the stand to fasten the display using the holes provided at the rear of the stand See the stand P 42TT29 type instruction manual for more information 25 When using the wall mounting unit Ve...

Page 23: ... hole ø30 4 14x25 Oval hole 200 300 200 300 Dimensions Unit mm General view Unit mm Floor Pipe Ornamental adapter Flange Ceiling board Ceiling C installment height 156 0 Flange pipe length B interior ceiling size A Size of the opposite side of ceiling Center of display Selection of pipe length x Unit mm Set name Pipe length X Combined length S 0400 a b 1 400 1 500 1 450 1 550 A 0600 a b 1 600 1 70...

Page 24: ...lay Hole position caution Screw A M5 screw with washer 2 each Screw A M5 screw with washer Fixing fitting Suspension fitting e Hanging on the Wall Mounting Unit Suspension fitting Screw B Shaft L 30cm Wall r Cabling Display Fasten at the lowest position of the oval hole t Fastening the display Display Shaft fixing fitting L Fixing fitting Shaft fixing fitting R Screw C M4 screw with washer 2 each ...

Page 25: ...y installation angle of 0 to 5 horizontal and vertical installation For a display installation angle of 5 to 15 horizontal installation only For an angle of 0 to 5 fasten at two places the arm mounting screws A and the lock fitting mounting screws C 4 places on both sides For an angle of 5 to 15 fasten only at the arm mounting screws B 2 places on both sides Remove the lock fitting mounting screws...

Page 26: ... assembling the PFC PCB fuse will blow 3 After the power cord plug was pulled out do not pull out the connector on the Main Power PCB until the Green LED D531 Discharge check LED turns off PDS4229 Rear Case Fan PFC PCB Main Power PCB Main Digital PCB Base Frame PFC PCB Main Power PCB Bezel Front Optical Filter Rear Case Key Switch Box Key Switch PCB Video Unit Video PCB PDP Unit PDP Unit Assy DISA...

Page 27: ... assembling the PFC PCB fuse will blow 3 After the power cord plug was pulled out do not pull out the connector on the Main Power PCB until the Green LED D531 Discharge check LED turns off PDS4229 Rear Case Fan PFC PCB Main Power PCB Main Digital PCB Base Frame PFC PCB Main Power PCB Bezel Front Optical Filter Rear Case Key Switch Box Key Switch PCB Video Unit Video PCB PDP Unit PDP Unit Assy DISA...

Page 28: ... 1 Remove the 22 circled screws and remove the Rear Case A PFC PCB C Main Digital PCB B Main Power PCB D Video PCB Layout of main PCB Note If the PFC PCB insulation sheet is not installed when assembling the PFC PCB fuse will blow ...

Page 29: ... 31 2 Removing the Fan 1 Remove the Rear Case 2 Remove the hook holding the Fan 3 Remove the Holder Fan 4 Remove the Fan and wire connector ...

Page 30: ... sheet Note If the PFC PCB insulation sheet is not installed when assembling the PFC PCB fuse will blow 2 Disconnect the connector and ground wire connected to the PCB 3 Remove the two hooks holding the PCB and remove the PCB View after PFC PCB removed ...

Page 31: ...oving the Main Power PCB 1 Remove the Rear Case 2 Remove 2 circled screws and remove the Option Frame 3 Remove the circled connector 4 Remove the 4 screws and the Main Power PCB View after Main Power PCB removed ...

Page 32: ...emove the Rear Case 2 Remove the Video Unit 3 Remove the circled screw and remove the Interface PCB from the Main Digital PCB Disconnect CN2004 4 Disconnect the connectors on the Main Digital PCB CN351 CN352 CN751 CN752 CN951 CN953 CN954 AND CN201 ...

Page 33: ...ital PCB 2 of 2 5 Remove the Rear Panel 4 Hex screws and 1 screw 6 Remove the 4 screws at the shield bracket of the Main Digital PCB and remove the shield bracket 7 Remove the Main Digital PCB View after Main Digital PCB removed ...

Page 34: ...ors CN751 and CN742 and remove their wires to the outside of the Main Unit 3 Remove the 6 circled screws Two screws indicated by the arrows are inside stand cover 4 Remove the Base Frame from the Front Case together with a panel and PCBs View of removal of the Base Frame from the Front Case ...

Page 35: ...and the 11 circled screws 6 Disconnect connectors CN201 CN351 CN352 CN501 and AC Inlet 3 pins 7 Remove the Base Frame together with the other parts 8 Remove the PFC PCB Refer to Removing the PFC PCB on page 32 9 Remove the shield plate under the PFC PCB and Main Power PCB Refer to Removing the Main Power PCB on page 33 ...

Page 36: ... the PDP Unit 3 of 3 10 Remove the insulation sheet under the Main Power PCB and each connector View after only the PDP Unit removed Replace the parts which are already mounted correctly when the PDP Unit is replaced ...

Page 37: ...l Front 1 Remove the 2 circled Cover Stands and remove the screw in the holes 2 Lift the bottom of the Bezel Front 3 Lift the Bezel Front upward to remove it The top of the Bezel Front is hooked View after Bezel Front removed ...

Page 38: ...0 8 Removing the Optical Filter 1 Remove the Bezel Front 2 Remove the 14 screws on the Filter Holders at each side 3 Remove by sliding the Filter Holder in the arrow directions 4 Remove the Optical Filter ...

Page 39: ... 41 9 Removing the Key Switch PCB 1 Remove the Bezel Front 2 Remove the rear case 3 Remove by tilting the key switch part forward 4 Unhook the hook holding the key switch PCB 5 Remove the key switch PCB ...

Page 40: ...Case 1 Remove the 4 circled screws 2 Pull out the Video PCB Unit from the plasmavision 3 Remove the 5 screws from the Video PCB Unit Note Three kinds of screws are used on this Video Unit Be careful not to make any mistakes when reinstalling 4 Remove the Video PCB Video Unit Video PCB ...

Page 41: ...CB Assy M00GND 8111594005 LED PHOTO PCB ASSY M00GNE 8111596009 Temperature sensor IC757 0100055016 Connection PCB M00GNB 8111590007 PDP Unit FPF42C10660UE 41 8110753007 Optical Filter 8111500013 Fan Motor 8900233009 Noise Filter 0400222170 Power Cord VDE 8111726000 UL CSA 8111725003 Remote Control Unit 8108442005 Packing Packing Pad Top 2 pcs 8111629004 Packing Pad BTM 2 pcs 8111630000 Carton box ...

Page 42: ...ON AND HANDLING RESTRICTIONS Transportation Don t load the plasmavision on a truck as shown in the drawing Don t hold the surface of the optical filter Over 30 cm Drop Floor Bad loading Handling Never drop Never topple ...

Page 43: ... 45 Don t stack the plasmavision over three units high Load the plasmavision as shown above Example of good transportation and handling Good loading 3 4 ...

Page 44: ...May 2001 Printed in Japan 0105J1859 ...

Reviews: