Page 1: ...C141 E116 01EN MPG3xxxAH E DISK DRIVES PRODUCT MANUAL ...

Page 2: ...REVISION RECORD Edition Date published Revised contents 01 Oct 2000 Specification No C141 E116 EN The contents of this manual is subject to change without prior notice All Rights Reserved Copyright 2000 FUJITSU LIMITED ...

Page 3: ...This page is intentionally left blank ...

Page 4: ...ES PRODUCT MANUAL C141 E116 This manual DEVICE OVERVIEW DEVICE CONFIGURATION INSTALLATION CONDITIONS THEORY OF DEVICE OPERATION INTERFACE OPERATIONS MPG3xxxAH E DISK DRIVES MAINTENANCE MANUAL C141 F050 MAINTENANCE AND DIAGNOSIS REMOVAL AND REPLACEMENT PROCEDURE ...

Page 5: ...This page is intentionally left blank ...

Page 6: ...k drives into user systems This manual assumes that users have a basic knowledge of hard disk drives and their application in computer systems This manual consists of the following six chapters Chapter 1 DEVICE OVERVIEW Chapter 2 DEVICE CONFIGURATION Chapter 3 INSTALLATION CONDITIONS Chapter 4 THEORY OF DEVICE OPERATION Chapter 5 INTERFACE Chapter 6 OPERATIONS In this manual disk drives may be ref...

Page 7: ... situation could result in minor or moderate personal injury if the user does not perform the procedure correctly This alert signal also indicates that damages to the product or other property may occur if the user does not perform the procedure correctly This indicates information that could help the user use the product more efficiently In the text the alert signal is centered followed below by ...

Page 8: ...ve adjustment repair or replacement Fujitsu is not liable for any other disk drive defects such as those caused by user misoperation or mishandling inappropriate operating environments defects in the power supply or cable problems of the host system or other causes outside the disk drive ...

Page 9: ...This page is intentionally left blank ...

Page 10: ...1 5 Acoustic Noise 1 8 1 6 Shock and Vibration 1 9 1 7 Reliability 1 9 1 8 Error Rate 1 10 1 9 Media Defects 1 10 CHAPTER 2 DEVICE CONFIGURATION 2 1 2 1 Device Configuration 2 1 2 2 System Configuration 2 3 2 2 1 ATA interface 2 3 2 2 2 1 drive connection 2 3 2 2 3 2 drives connection 2 3 CHAPTER 3 INSTALLATION CONDITIONS 3 1 3 1 Dimensions 3 1 3 2 Handling Cautions 3 3 3 2 1 General notes 3 3 3 2...

Page 11: ... 2 3 Spindle 4 2 4 2 4 Actuator 4 3 4 2 5 Air filter 4 3 4 3 Circuit Configuration 4 4 4 4 Power on Sequence 4 6 4 5 Self calibration 4 8 4 5 1 Self calibration contents 4 8 4 5 2 Execution timing of self calibration 4 9 4 5 3 Command processing during self calibration 4 9 4 6 Read write Circuit 4 10 4 6 1 Read write preamplifier PreAMP 4 10 4 6 2 Write circuit 4 10 4 6 3 Read circuit 4 11 4 6 4 S...

Page 12: ...81 5 4 4 Other commands 5 82 5 4 5 DMA data transfer commands 5 82 5 5 Ultra DMA feature set 5 84 5 5 1 Overview 5 84 5 5 2 Phases of operation 5 85 5 5 3 Ultra DMA data in commands 5 85 5 5 3 1 Initiating an Ultra DMA data in burst 5 85 5 5 3 2 The data in transfer 5 86 5 5 3 3 Pausing an Ultra DMA data in burst 5 86 5 5 3 4 Terminating an Ultra DMA data in burst 5 87 5 5 4 Ultra DMA data out com...

Page 13: ... 10 Host terminating an Ultra DMA data out burst 5 108 5 6 3 11 Device terminating an Ultra DMA data in burst 5 109 5 6 4 Power on and reset 5 110 CHAPTER 6 OPERATIONS 6 1 6 1 Device Response to the Reset 6 1 6 1 1 Response to power on 6 2 6 1 2 Response to hardware reset 6 3 6 1 3 Response to software reset 6 4 6 1 4 Response to diagnostic command 6 5 6 2 Address Translation 6 6 6 2 1 Default par...

Page 14: ...on using CBLID signal Host sensing the condition of the CBLID signal 3 12 3 13 Cable type detection using IDENTIFY DEVICE data Device sensing the condition of the CBLID signal 3 12 3 14 Jumper location 3 13 3 15 Factory default setting 3 14 3 16 Jumper setting of master or slave device 3 14 3 17 Jumper setting of Cable Select 3 15 3 18 Example 1 of Cable Select 3 15 3 19 Example 2 of Cable Select ...

Page 15: ... DMA data in burst 5 103 5 14 Host terminating an Ultra DMA data in burst 5 104 5 15 Initiating an Ultra DMA data out burst 5 105 5 16 Sustained Ultra DMA data out burst 5 106 5 17 Device pausing an Ultra DMA data out burst 5 107 5 18 Host terminating an Ultra DMA data out burst 5 108 5 19 Device terminating an Ultra DMA data out burst 5 109 5 20 Power on Reset Timing 5 110 6 1 Response to power o...

Page 16: ... 29 5 6 Features register values and settable modes 5 36 5 7 Diagnostic code 5 40 5 8 Features Register values subcommands and functions 5 50 5 9 Device attribute data structure 5 53 5 10 Warranty failure threshold data structure 5 54 5 11 Log directory data structure 5 59 5 12 Error logging data structure 5 60 5 13 Self Test log data structure 5 61 5 14 Contents of security password 5 63 5 15 Con...

Page 17: ...This page is intentionally left blank ...

Page 18: ...drive is compact and reliable 1 1 Features 1 1 1 Functions and performance 1 Compact The disk has 1 or 2 disks of 95 mm 3 5 inches diameter and its height is 26 1 mm 1 inch 2 Large capacity The disk drive can record up to 20 49 GB formatted on one disk using the 48 52 EEPR4ML recording method and 15 recording zone technology The MPG3xxxAH E series have a formatted capacity of 20 49 GB to 40 99 GB ...

Page 19: ...the disk drive can be connected to an ATA interface of a personal computer 2 2MB data buffer The disk drive uses a 2MB data buffer to transfer data between the host and the disk media In combination with the read ahead cache system described in item 3 and the write cache described in item 6 the buffer contributes to efficient I O processing 3 Read ahead cache system After the execution of a disk r...

Page 20: ...ry The 40 bytes ECC has improved buffer error correction for correctable data errors 6 Write cache When the disk drive receives a write command the disk drive posts the command completion at completion of transferring data to the data buffer completion of writing to the disk media This feature reduces the access time at writing ...

Page 21: ...ite 17 ms typical Positioning time Slow Minimum Average Maximum Read 0 8 ms typical Write 1 0 ms typical Read 11 ms typical Write 12 ms typical Read 20 ms typical Write 21 ms typical Start Stop time Start 0 rpm to Drive Read Stop at Power Down Typical 8 sec Maximum 15 sec Typical 20 sec Maximum 30 sec Interface ATA 5 Maximum Cable length 0 46 m Data Transfer Rate To From Media 38 0 to 60 7 MB s 27...

Page 22: ...lists the model names and product numbers Table 1 2 Model names and product numbers Model Name Capacity user area Mounting Screw Order No Remarks MPG3204AH E 20 49 GB No 6 32UNC CA05762 B521 MPG3307AH E 30 74 GB No 6 32UNC CA05762 B544 MPG3409AH E 40 99 GB No 6 32UNC CA05762 B542 1 3 Power Requirements 1 Input Voltage 5 V 5 12 V 8 2 Ripple 12 V 5 V Maximum 200 mV peak to peak 100 mV peak to peak F...

Page 23: ...8 18 120 0 8 0 8 0 8 Energy efficiency rank 6 watt GB 0 327 A 0 237 B 0 178 B 1 Current is typical rms except for spin up 2 Power requirements reflect nominal values for 12V and 5V power 3 Idle mode is in effect when the drive is not reading writing seeking or executing any commands A portion of the R W circuitry is powered down the spindle motor is up to speed and the Drive ready condition exists...

Page 24: ... 1 Current fluctuation Typ when power is turned on 5 Power on off sequence The voltage detector circuit monitors 5 V and 12 V The circuit does not allow a write signal if either voltage is abnormal This prevents data from being destroyed and eliminates the need to be concerned with the power on off sequence ...

Page 25: ... RH Non condensing 5 to 85 RH Non condensing 29 C Altitude relative to sea level Operating Non operating 60 to 3 000 m 200 to 10 000 ft 60 to 12 000 m 200 to 40 000 ft 1 5 Acoustic Noise Table 1 5 lists the acoustic noise specification Table 1 5 Acoustic noise specification Model MPG3204AH E MPG3307AH E MPG3409AH E Idle mode DRIVE READY 3 6 bels 3 3 bels Sound Power per ISO 7779 and ISO9296 Typica...

Page 26: ...failures MTBF is 500 000 POH power on hours or more operation 24 hours day 7 days week This does not include failures occurring during the first three months after installation MTBF is defined as follows MTBF H Disk drive defects refers to defects that involve repair readjustment or replacement Disk drive defects do not include failures caused by external factors such as damage caused by handling ...

Page 27: ...ernative blocks can be assigned are not included in the error rate count below It is assumed that the data blocks to be accessed are evenly distributed on the disk media 1 Unrecoverable read error Read errors that cannot be recovered by read retries without user s retry and ECC corrections shall occur no more than 10 times when reading data of 1015 bits Read retries are executed according to the d...

Page 28: ...iguration 2 1 Device Configuration Figure 2 1 shows the disk drive The disk drive consists of a disk enclosure DE read write preamplifier and controller PCA The disk enclosure contains the disk media heads spindle motors actuators and a circulating air filter Figure 2 1 Disk drive outerview ...

Page 29: ...sitioned by feedback of the servo information read by the read write head If the power is not on or if the spindle motor is stopped the head assembly stays in the specific CSS zone on the disk and is fixed by a mechanical lock 5 Air circulation system The disk enclosure DE is sealed to prevent dust and dirt from entering The disk enclosure features a closed loop air circulation system that relies ...

Page 30: ...ansfer till 66 6 MB s Ultra DMA mode 4 and the ultra DMA transfer till 100 MB s Ultra mode 5 2 2 2 1 drive connection ATA interface AT bus Host interface Disk drive HA Host adaptor Host Figure 2 2 1 drive system configuration 2 2 3 2 drives connection ATA interface AT bus Host interface Disk drive 1 Disk drive 0 HA Host adaptor Host Note When the drive that is not conformed to ATA is connected to ...

Page 31: ...DMA mode 2 ultra DMA mode 4 or ultra DMA mode 5 occurrence of ringing or crosstalk of the signal lines AT bus between the HA and the disk drive may be a great cause of the obstruction of system reliability Thus it is necessary that the capacitance of the signal lines including the HA and cable does not exceed the ATA 3 ATA 4 and ATA 5 standard and the cable length between the HA and the disk drive...

Page 32: ...N CONDITIONS 3 1 Dimensions 3 2 Handling Cautions 3 3 Mounting 3 4 Cable Connections 3 5 Jumper Settings 3 1 Dimensions Figure 3 1 illustrates the dimensions of the disk drive and positions of the mounting screw holes All dimensions are in mm ...

Page 33: ...C141 E116 01EN 3 2 Figure 3 1 Dimensions ...

Page 34: ...e driver 2 Please observe the tightening torque of the screw strictly 6 32UNC Max 0 59 N m 6 Kg cm 3 2 3 Recommended equipments Contents Model Maker Wrist strap JX 1200 3056 8 SUMITOMO 3M ESD ESD mat 76000DES ASK7876 COMKYLE Shock Low shock driver SS 3000 HIOS Place the shock absorbing mat on the operation table and place ESD mat on it Wrist strap Use the Wrist strap Do not hit HDD each other Do n...

Page 35: ... is connected to signal ground SG and the mounting frame is also connected to signal ground These are electrically shorted Note Use No 6 32UNC screw for the mounting screw and the screw length should satisfy the specification in Figure 3 5 3 Limitation of side mounting When the disk drive is mounted using the screw holes on both side of the disk drive use two screw holes shown in Figure 3 4 Do not...

Page 36: ...e 3 5 Mounting frame structure 5 0 or less 4 5 or less 2 B Frame of system cabinet Details of B Details of A Frame of system cabinet Screw Screw PCA DE 2 5 2 5 2 5 A DE Side surface mounting Bottom surface mounting Do not use this screw holes Use these screw holes ...

Page 37: ... in the cabinet such that the PCA side in particular receives sufficient cooling To check the cooling efficiency measure the surface temperatures of the DE Regardless of the ambient temperature this surface temperature must meet the standards listed in Table 3 1 Figure 3 6 shows the temperature measurement point Figure 3 6 Surface temperature measurement points Table 3 1 Surface temperature measur...

Page 38: ...on Figure 3 7 Service area 6 External magnetic fields Avoid mounting the disk drive near strong magnetic sources such as loud speakers Ensure that the disk drive is not affected by external magnetic fields P side Cable connection Mode setting switches R side Mounting screw hole Mounting screw hole Q side Mounting screw hole ...

Page 39: ...connectors and terminals listed below for connecting external devices Figure 3 8 shows the locations of these connectors and terminals Power supply connector CN1 ATA interface connector CN1 Figure 3 8 Connector locations Power supply connector CN1 Mode Setting Pins ATA interface connector ...

Page 40: ... housing 1 480424 0 AMP Contact 60617 4 AMP Note The cable of twisted pairs and neighboring line separated individually is not allowed to use for the host interface cable It is because that the location of signal lines in these cables is not fixed and so the problem on the crosstalk among signal lines may occur It is recommended to use the ribbon cable for ATA interface that cable length is less t...

Page 41: ... a fine pitch cable to double the number of conductors available to the 40 pin connector The grounds assigned by the interface are commoned with the additional 40 conductors to provide a ground between each signal line and provide the effect of a common ground plane 2 The cable assembly may contain up to 3 connectors which shall be uniquely colored as follows All connectors shall have position 20 ...

Page 42: ...able configuration b Host system that do support Ultra DMA modes greater than mode 2 shall either connect directly to the device without using a cable assembly or determine the cable assembly type Determining the cable assembly type may be done either by the host sensing the condition of the PDIAG CBLID signal see Figure 3 12 or by relying on information from the device see Figure 3 13 Hosts that ...

Page 43: ...sensing the condition of the CBLID signal open 0 047 µF 10 or 20 Host Device 0 Device 1 with 80 conductor cable with 40 conductor cable PDIAG CBLID conductor PDIAG CBLID conductor IDENTIFY DEVICE information word 93 bit13 1 Device detected CBLID above VIH IDENTIFY DEVICE information word 93 bit13 0 Device detected CBLID below VIL Host Device 0 Device 1 0 047 µF 10 or 20 Figure 3 13 Cable type dete...

Page 44: ... 3 5 Jumper Settings 3 5 1 Location of setting jumpers Figure 3 14 shows the location of the jumpers to select drive configuration and functions Figure 3 14 Jumper location Interface Connector DC Power Connector 1 2 1 40 ...

Page 45: ...elected 8 6 4 2 a Master device shorted b Slave device 9 7 5 3 1 8 6 4 2 9 7 5 3 1 Figure 3 16 Jumper setting of master or slave device Note When the device type is set by the jumper on the device the device should not be configured for cable selection 2 Cable Select CSEL In Cable Select mode the device can be configured either master device or slave device For use of Cable Select function Unique ...

Page 46: ...f the cable and connecting it to ground further the CSEL is set to low level The device is identified as a master device At this time the CSEL of the slave device does not have a conductor Thus since the slave device is not connected to the CSEL conductor the CSEL is set to high level The device is identified as a slave device Open CSEL conductor GND Slave device Master device Host system Figure 3...

Page 47: ... 6 4 2 9 7 5 3 1 8 6 4 2 9 7 5 3 1 Model No of cylinders No of heads No of sectors Capacity MPG3204AH E 4 092 16 63 2 1 GB MPG3307AH E 4 092 16 63 2 1 GB MPG3409AH E 16 383 16 63 33 8 GB b Slave present If the slave device does not use the Device Active Slave Present DASP signal to indicate its presence the device is configured as a Master with slave present when the following jumper settings is a...

Page 48: ...nd drive control method 4 2 Subassemblies The disk drive consists of a disk enclosure DE and printed circuit assembly PCA The DE contains all movable parts in the disk drive including the disk spindle actuator read write head and air filter For details see Subsections 4 2 1 to 4 2 5 The PCA contains the control circuits for the disk drive The disk drive has one PCA For details see Sections 4 3 4 2...

Page 49: ...he spindle consists of a disk stack assembly and spindle motor The disk stack assembly is activated by the direct drive sensor less DC spindle motor which has a speed of 7 200 rpm The spindle is controlled with detecting a PHASE signal generated by counter electromotive voltage of the spindle motor at starting After that the rotational speed is kept with detecting a servo information Spindle Actua...

Page 50: ...lter There are two types of air filters a breather filter and a circulation filter The breather filter makes an air in and out of the DE to prevent unnecessary pressure around the spindle when the disk starts or stops rotating When disk drives are transported under conditions where the air pressure changes a lot filtered air is circulated in the DE The circulation filter cleans out dust and dirt f...

Page 51: ...ains the 48 52 group coded recording GCR encoder and decoder and servo demodulation circuit 2 Servo circuit The position and speed of the voice coil motor are controlled by 2 closed loop servo using the servo information recorded on the data surface The servo information is an analog signal converted to digital for processing by a MPU and then reconverted to an analog signal for control of the voi...

Page 52: ...xAH Block diagram Data Buffer SDRAM Flash ROM FROM SVC HA13627 HDC MCU RDC CL SH8671 Himalaya 2 MCU ARM7TDMI RDC Number B HDC CL SH7660 Resonator 20MHz SP Motor VCM Temp Sensor R W Pre Amp SR1756 or M61850 HEAD Media ATA Interface PCA DE ...

Page 53: ... read write test after enabling response to the ATA bus c After confirming that the spindle motor has reached rated speed the disk drive releases the heads from the actuator magnet lock mechanism by applying current to the VCM This unlocks the heads which are parked at the inner circumference of the disks d The disk drive positions the heads onto the SA area and reads out the system information e ...

Page 54: ...uffer write read test The spindle motor starts Self diagnosis 1 MPU bus test Inner register write read test Work RAM write read test Start Power on Drive ready state command waiting state Execute self calibration Initial on track and read out of system information f e d End Figure 4 3 Power on operation sequence ...

Page 55: ...ation The measured values are stored in the SA cylinder In the self calibration the compensating value is updated using the value in the SA cylinder 2 Compensating open loop gain Torque constant value of the VCM has a dispersion for each drive and varies depending on the cylinder that the head is positioned To realize the high speed seek operation the value that compensates torque constant value c...

Page 56: ...ing self calibration If the disk drive receives a command execution request from the host while executing self calibration according to the timechart the disk drive terminates self calibration and starts executing the command precedingly In other words if a disk read or write service is necessary the disk drive positions the head to the track requested by the host reads or writes data Then restart...

Page 57: ...The IC generates a write error sense signal WUS when a write error occurs due to head short circuit or head disconnection 4 6 2 Write circuit The write data is output from the hard disk controller HDC with the NRZ data format and sent to the encoder circuit in the RDC with synchronizing with the write clock The NRZ write data is converted from 48 bits data to 52 bits data by the encoder circuit th...

Page 58: ...cessary high frequency noise component and a high frequency boost up function that equalizes the waveform of the read signal Cut off frequency of the low pass filter and boost up gain are controlled from each DAC circuit in read channel The MPU optimizes the cut off frequency and boost up gain according to the transfer frequency of each zone 3 FIR Digital Finite Impulse Response Equalization Filte...

Page 59: ... to 9823 9824 to 13119 13120 to 15615 15616 to 17087 17088 to 19359 Transfer rate MB s 49 73 48 87 47 22 45 79 43 61 41 88 41 01 39 28 Zone 8 9 10 11 12 13 14 Cylinder 19360 to 22047 22048 to 23839 23840 to 25247 25248 to 26591 26592 to 28767 28768 to 30175 30176 to 30783 Transfer rate MB s 37 22 35 77 34 62 33 45 31 43 30 12 27 92 MPG3204AH E MPG3409AH E Zone 0 1 2 3 4 5 6 7 Cylinder 0 to 2783 27...

Page 60: ...escribes the functions of the blocks 5 1 2 3 4 P Amp CSR Current Sense Resistor VCM Voice Coil Motor Spindle motor control DSP unit Servo burst capture SVC MPU CSR Driver DAC ADC Position Sense Head VCM current VCM Spindle motor 7 6 Figure 4 4 Block diagram of servo control circuit 1 Microprocessor unit MPU The MPU includes DSP unit etc and the MPU starts the spindle motor moves the heads to the r...

Page 61: ...e data area The logical initial cylinder is at the outermost circumference cylinder 0 c Seek to specified cylinder Drives the VCM to position the head to the specified cylinder d Calibration Senses and stores the thermal offset between heads and the mechanical forces on the actuator and stores the calibration value ...

Page 62: ... The four servo signals can be synchronously detected by the DEMOD signal internal full wave rectified integrated 3 A D converter ADC The A D converter ADC receives the servo signals are integrated converts them to digital and transfers the digital signal to the DSP unit Servo frame 96 servo frames per revolution ...

Page 63: ...a power amplitude circuit that receives signals from the spindle motor control circuit and feeds currents to the spindle motor 8 VCM current sense resistor CSR This resistor controls current at the power amplifier by converting the VCM current into voltage and feeding back 4 7 2 Data surface servo format Figure 4 5 describes the physical layout of the servo frame The three areas indicated by 1 to ...

Page 64: ...ion and position detection of circumstance direction The servo frame consists of 5 blocks write read recovery servo mark gray code Pos A to D and PAD Figure 4 6 shows the servo frame format Pos C PAD Pos D Pos B Pos A 1 81 µs 0 17 µs 0 16 µs 0 72 µs R W Recovery Field 0 56 µs 0 56 µs 0 56 µs 0 74 µs 0 80 µs PA SSM ASM SCD 0 53 µs Servo Frame DATA DATA Servo Frame 86 81 µs 6 63 µs Figure 4 6 96 ser...

Page 65: ...vo and data 4 7 4 Actuator motor control The voice coil motor VCM is controlled by feeding back the servo data recorded on the data surface The MPU fetches the position sense data on the servo frame at a constant interval of sampling time executes calculation and updates the VCM drive current The servo control of the actuator includes the operation to move the head to the reference cylinder the se...

Page 66: ...h sampling time the VCM drive current is determined by filtering the position difference between the target position and the position clarified by the detected position sense data The filtering includes servo compensation These are digitally controlled by the firmware 4 7 5 Spindle motor control Hall less three phase eight pole motor is used for the spindle motor and the 3 phase full half wave ana...

Page 67: ...celerates till the rotational speed reaches 7 200 rpm When the rotational speed reaches 7 200 rpm the SVC enters the stable rotation mode 3 Stable rotation mode The MPU calculates a time for one revolution of the spindle motor based on the PHASE signal from the SVC The MPU takes a difference between the current time and a time for one revolution at 7 200 rpm that the MPU already recognized Then th...

Page 68: ...C141 E116 01EN 5 1 CHAPTER 5 INTERFACE 5 1 Physical Interface 5 2 Logical Interface 5 3 Host Commands 5 4 Command Protocol 5 5 Ultra DMA feature set 5 6 Timing ...

Page 69: ... Data bus bit 12 DD12 Data bus bit 13 DD13 Data bus bit 14 DD14 Data bus bit 15 DD15 Device active or slave present see note DASP Device address bit 0 DA0 Device address bit 1 DA1 Device address bit 2 DA2 DMA acknowledge DMACK DMA request DMARQ Interrupt request INTRQ I O read DIOR DMA ready during Ultra DMA data in bursts HDMARDY Data strobe during Ultra DMA data out bursts HSTROBE I O ready IORD...

Page 70: ... GND GND CSEL GND reserved PDIAG CBLID DA2 CS1 GND signal I O Description RESET I Reset signal from the host This signal is low active and is asserted for a minimum of 25 µs during power on The device has a 10 kΩ pull up resistor on this signal DATA 0 15 I O Sixteen bit bi directional data bus between the host and the device These signals are used for data transfer DIOW STOP I DIOW is the strobe s...

Page 71: ...ster When the device is not selected or interrupt is disabled the INTRQ Signal shall be in a high impedance state CS0 I Chip select signal decoded from the host address bus This signal is used by the host to select the command block registers CS1 I Chip select signal decoded from the host address bus This signal is used by the host to select the control block registers DA 0 2 I Binary decoded addr...

Page 72: ...n the IDD is a slave device This signal is pulled up with 10 kΩ resistor DMACK I The host system asserts this signal as a response that the host system receive data or to indicate that data is valid DMARQ O This signal is used for DMA transfer between the host system and the device The device asserts this signal when the device completes the preparation of DMA data transfer to the host system at r...

Page 73: ...tor Number registers are LBA bits The sector No under the LBA mode proceeds in the ascending order with the start point of LBA0 defined as follows LBA0 Cylinder 0 Head 0 Sector 1 Even if the host system changes the assignment of the CHS mode by the INITIALIZE DEVICE PARAMETER command the sector LBA address is not changed LBA Cylinder No Number of head Head No Number of sector track Sector No 1 5 2...

Page 74: ...nd X 1F7 1 1 X X X Invalid Invalid Control block registers 0 1 1 1 0 Alternate Status Device Control X 3F6 0 1 1 1 1 X 3F7 Notes 1 The Data register for read or write operation can be accessed by 16 bit data bus DATA0 to DATA15 2 The registers for read or write operation other than the Data registers can be accessed by 8 bit data bus DATA0 to DATA7 3 When reading the Drive Address register bit 7 i...

Page 75: ... IDNF X ABRT TK0NF AMNF X Unused Bit 7 Interface CRC error ICRC This bit indicates that an interface CRC error has occurred during an Ultra DMA data transfer The content of this bit is not applicable for Multiword DMA transfers Bit 6 Uncorrectable Data Error UNC This bit indicates that an uncorrectable data error has been encountered Bit 5 Unused Bit 4 ID Not Found IDNF This bit indicates an error...

Page 76: ...ation between the host system and the device When the value in this register is X 00 the sector count is 256 When this register indicates X 00 at the completion of the command execution this indicates that the command is completed successfully If the command is not completed successfully this register indicates the number of sectors to be transferred to complete the request from the host system Th...

Page 77: ...h order 8 bits of the cylinder address are set to the Cylinder High register Under the LBA mode this register indicates LBA bits 23 to 16 8 Device Head register X 1F6 The contents of this register indicate the device and the head number When executing INITIALIZE DEVICE PARAMETERS command the contents of this register defines the number of heads minus 1 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit...

Page 78: ... ns after RESET is negated or SRST is set in the Device Control register the BSY bit is set The BSY bit is cleared when the reset process is completed The BSY bit is set for no longer than 15 seconds after the IDD accepts reset b Within 400 ns from the host system starts writing to the Command register c Within 5 µs following transfer of 512 bytes data during execution of the READ SECTOR S WRITE S...

Page 79: ...us command was being executed The Error register indicates the additional information of the cause for the error 10 Command register X 1F7 The Command register contains a command code being sent to the device After this register is written the command execution starts immediately Table 5 3 lists the executable commands and their command codes This table also lists the necessary parameters for each...

Page 80: ...sets both devices simultaneously The slave device is not required to execute the DASP handshake Bit 1 nIEN bit enables an interrupt INTRQ signal from the device to the host When this bit is 0 and the device is selected an interruption INTRQ signal can be enabled through a tri state buffer When this bit is 1 or the device is not selected the INTRQ signal is in the high impedance state 5 3 Host Comm...

Page 81: ...Y WRITE SECTOR S 0 0 1 1 0 0 0 R N Y Y Y Y RECALIBRATE 0 0 0 1 X X X X N N N N D SEEK 0 1 1 1 X X X X N N Y Y Y INITIALIZE DEVICE DIAGNOSTIC 1 0 0 1 0 0 0 1 N Y N N Y IDENTIFY DEVICE 1 1 1 0 1 1 0 0 N N N N D IDENTIFY DEVICE DMA 1 1 1 0 1 1 1 0 N N N N D SET FEATURES 1 1 1 0 1 1 1 1 Y N N N D SET MULTIPLE MODE 1 1 0 0 0 1 1 0 N Y N N D EXECUTE DEVICE DIAGNOSTIC 1 0 0 1 0 0 0 0 N N N N D FORMAT TRA...

Page 82: ... FREEZE LOCK 1 1 1 1 0 1 0 1 N N N N D SECURITY SET PASSWORD 1 1 1 1 0 0 0 1 N N N N D SECURITY UNLOCK 1 1 1 1 0 0 1 0 N N N N D SET MAX ADDRESS 1 1 1 1 1 0 0 1 N Y Y Y Y READ NATIVE MAX ADDRESS 1 1 1 1 1 0 0 0 N N N N D Notes FR Features Register CY Cylinder Registers SC Sector Count Register DH Drive Head Register SN Sector Number Register R R 0 or 1 Y Necessary to set parameters Y Necessary to ...

Page 83: ... cylinder address LSB LBA Start sector No LBA LSB Transfer sector count xx At command completion I O registers contents to be read Bit 7 6 5 4 3 2 1 0 1F7H ST Error information 1F6H DH L DV End Head No LBA MSB 1F5H CH 1F4H CL 1F3H SN 1F2H SC 1F1H ER End cylinder address MSB LBA End cylinder address LSB LBA End sector No LBA LSB X 00 Error information CM Command register FR Features register DH Dev...

Page 84: ... is not on the track specified by the host the device performs an implied seek After the head reaches to the specified track the device reads the target sector The DRQ bit of the Status register is always set prior to the data transfer regardless of an error condition Upon the completion of the command execution command block registers contain the cylinder head and sector addresses in the CHS mode...

Page 85: ...ULTIPLE MODE command should be executed prior to the READ MULTIPLE command When the READ MULTIPLE command is issued the Sector Count register contains the number of sectors requested not a number of the block count or a number of sectors in a block Upon receipt of this command the device executes this command even if the value of the Sector Count register is less than the defined block count the v...

Page 86: ...xecution example of READ MULTIPLE command At command issuance I O registers setting contents 1F7H CM 1 1 0 0 0 1 0 0 1F6H DH L DV Start head No LBA MSB 1F5H CH 1F4H CL 1F3H SN 1F2H SC 1F1H FR Start cylinder No MSB LBA Start cylinder No LSB LBA Start sector No LBA LSB Transfer sector count xx At command completion I O registers contents to be read 1F7H ST Status information 1F6H DH L DV End head No...

Page 87: ...rror information is the same as the READ SECTOR S command In LBA mode The logical block address is specified using the start head No start cylinder No and first sector No fields At command completion the logical block address of the last sector and remaining number of sectors of which data was not transferred like in the CHS mode are set The host system can select the DMA transfer mode by using th...

Page 88: ... BSY bit of the Status register and generates an interrupt Upon the completion of the command execution the command block registers contain the cylinder head and sector number of the last sector verified If an error occurs the verify operation is terminated at the sector where the error occurred The command block registers contain the cylinder the head and the sector addresses in the CHS mode or t...

Page 89: ...y the host the device performs an implied seek After the head reaches to the specified track the device writes the target sector The data stored in the buffer and CRC code and ECC bytes are written to the data field of the corresponding sector s Upon the completion of the command execution the command block registers contain the cylinder head and sector addresses of the last sector written If an e...

Page 90: ... MODE command should be executed prior to the WRITE MULTIPLE command When the WRITE MULTIPLE command is issued the Sector Count register contains the number of sectors requested not a number of the block count or a number of sectors in a block Upon receipt of this command the device executes this command even if the value of the Sector Count register is less than the defined block count the value ...

Page 91: ... Error information Note When the command terminates due to error only the DV bit and the error information field are valid 7 WRITE DMA X CA or X CB This command operates similarly to the WRITE SECTOR S command except for following events The data transfer starts at the timing of DMARQ signal assertion The device controls the assertion or negation timing of the DMARQ signal The device posts a statu...

Page 92: ... 1F4H CL 1F3H SN 1F2H SC 1F1H ER End cylinder No MSB LBA End cylinder No LSB LBA End sector No LBA LSB 00 1 Error information 1 If the command is terminated due to an error the remaining number of sectors of which data was not transferred is set in this register 8 WRITE VERIFY X 3C This command operates similarly to the WRITE SECTOR S command except that the device verifies each sector immediately...

Page 93: ...0 to X F This command performs the calibration Upon receipt of this command the device sets BSY bit of the Status register and performs a calibration When the device completes the calibration the device updates the Status register clears the BSY bit and generates an interrupt This command can be issued in the LBA mode At command issuance I O registers setting contents 1F7H CM 0 0 0 1 x x x x 1F6H ...

Page 94: ...e this command performs the seek operation to the cylinder and head position in which the sector is specified with the logical block address At command issuance I O registers setting contents 1F7H CM 0 1 1 1 x x x x 1F6H DH L DV Head No LBA MSB 1F5H CH 1F4H CL 1F3H SN 1F2H SC 1F1H FR Cylinder No MSB LBA Cylinder No LSB LBA Sector No LBA LSB xx xx At command completion I O registers contents to be ...

Page 95: ...thin a default area It is recommended that the host system refers the addressable user sectors total number of sectors in word 60 to 61 of the parameter information by the IDENTIFY DEVICE command At command issuance I O registers setting contents 1F7H CM 1 0 0 1 0 0 0 1 1F6H DH DV Max head No 1F5H CH 1F4H CL 1F3H SN 1F2H SC 1F1H FR xx xx xx Number of sectors track xx At command completion I O regi...

Page 96: ... Number of cylinders 2 X 0000 Reserved 3 3 Number of Heads 4 X 0000 Retired 5 X 0000 Retired 6 X 003F Number of sectors per track 7 9 X 000000000000 Retired 10 19 Serial number ASCII code 4 20 X 0003 Retired 21 X 1000 Buffer size in 512 byte increments 22 X 0004 Number of ECC bytes transferred at READ LONG or WRITE LONG command 23 26 Firmware revision ASCII code 5 27 46 Model number ASCII code 6 4...

Page 97: ...ime without flow control 120 ns 68 X 0078 Minimum PIO transfer cycle time with IORDY flow control 120 ns 69 79 X 00 Reserved 80 X 003E Major version number 14 81 X 0015 Minor version number ATA ATAPI5 X3T13 1321D Support of rev 1 82 X 346B Support of command sets 15 83 X 4108 Support of command sets 16 84 X 4000 Support of command set feature extension fixed 85 X xxxx Enable disable Command set fe...

Page 98: ...s Fujitsu MPG3204AH E Fujitsu MPG3307AH E Fujitsu MPG3409AH E 7 Word 49 Capabilities Bit 15 14 Reserved Bit 13 Standby timer value 0 Standby timer values shall be managed by the device Bit 12 Reserved Bit 11 IORDY support 1 Supported Bit 10 IORDY inhibition 0 Disable inhibition Bit 9 LBA support 1 Supported Bit 8 DMA support 1 Supported Bit 7 0 Vendor specific 8 Word 51 PIO data transfer mode Bit ...

Page 99: ...it 2 ATA 2 Supported 1 Bit 1 ATA 1 Supported 1 Bit 0 Undefined 15 Word 82 Support of command sets Bit 15 Reserved Bit 14 NOP command supported 0 Bit 13 Read Buffer command supported 1 Bit 12 Write Buffer command supported 1 Bit 11 Write Verify command supported Old Spec 0 Bit 10 Host Protected Area feature command supported 1 Bit 9 Device Reset command supported 0 Bit 8 SERVICE Interrupt supported...

Page 100: ...enabled Bit 8 1 SET MAX security extension enabled by SET MAX SET PASSWORD Bit 7 Reserved Bit 6 0 SET FEATURES subcommand required to spin up after power up Bit 5 0 Power Up In Standby feature set enabled Bit 4 0 Removable Media Status Notification feature set enabled Bit 3 1 Advanced Power Management feature set enabled Bit 2 0 CFA feature set enabled Bit 1 0 READ WRITE DMA QUEUED command support...

Page 101: ... 1 determined the device number 00 Reserved 01 a jumper was used 10 the CSEL signal was used 11 some other method was used or the method is unknown Bit 8 1 Bit 7 0 Device 0 hardware reset result Device 1 shall clear these bits to zero Device 0 shall set these bits as follows Bit 7 0 Bit 6 0 Device 0 does not respond when Device 1 is selected 1 Device 0 responds when Device 1 is selected Bit 5 0 De...

Page 102: ...formation 14 SET FEATURES X EF The host system issues the SET FEATURES command to set parameters in the Features register for the purpose of changing the device features to be executed For the transfer mode Feature register 03 detail setting can be done using the Sector Count register Upon receipt of this command the device sets the BSY bit of the Status register and saves the parameters in the Fe...

Page 103: ...are reset X 77 No operation X 81 No operation X 82 Disables the write cache function X 84 No operation X 85 Disable the advanced power management function X 88 No operation X 89 No operation X AA Enables the read cache function X AB No operation X BB Specifies the transfer of 4 byte ECC for READ LONG and WRITE LONG commands X C2 Disable Automatic Acoustic Management feature set X CC Enables the re...

Page 104: ... 3 bits specifies the binary mode value However the IDD can operate with the PIO transfer mode 4 and multiword DMA transfer mode 2 regardless of reception of the SET FEATURES command for transfer mode setting The IDD supports following values in the Sector Count register value If other value than below is specified an ABORTED COMMAND error is posted PIO default transfer mode 00000 000 X 00 PIO flo...

Page 105: ...then the acoustic behavior of the device shall be vendor specific and the device return zeros in bits 0 7 of word 94 and bit 9 of word 86 of the IDENTIFY DEVICE data 15 SET MULTIPLE MODE X C6 This command enables the device to perform the READ MULTIPLE and WRITE MULTIPLE commands The block count number of sectors in a block for these commands are also specified by the SET MULTIPLE MODE command The...

Page 106: ...CE command is issued are listed below See Subsection 5 3 2 for the IDENTIFY DEVICE command Word 47 8010 Word 59 0000 01xx Maximum number of sectors that can be transferred per interrupt by the READ MULTIPLE and WRITE MULTIPLE commands are 16 fixed The READ MULTIPLE and WRITE MULTIPLE commands are disabled The READ MULTIPLE and WRITE MULTIPLE commands are enabled xx indicates the current setting fo...

Page 107: ...not present The device 0 posts only the results of its own self diagnosis The device 0 clears the BSY bit of the Status register and generates an interrupt Table 5 7 lists the diagnostic code written in the Error register which is 8 bit code If the device 1 fails the self diagnosis the device 0 ORs X 80 with its own status and sets that code to the Error register Table 5 7 Diagnostic code Code Res...

Page 108: ...ng ECC function by combining with the WRITE LONG command The READ LONG command supports only single sector operation At command issuance I O registers setting contents 1F7H CM 0 0 1 0 0 0 1 R 1F6H DH L DV Head No LBA MSB 1F5H CH 1F4H CL 1F3H SN 1F2H SC 1F1H FR Cylinder No MSB LBA Cylinder No LSB LBA Sector No LBA LSB Number of sectors to be transferred xx R 0 or 1 At command completion I O registe...

Page 109: ...rmation 1F6H DH L DV Head No LBA MSB 1F5H CH 1F4H CL 1F3H SN 1F2H SC 1F1H ER Cylinder No MSB LBA Cylinder No LSB LBA Sector No LBA LSB 00 1 Error information 1 If the command is terminated due to an error this register indicates 01 20 READ BUFFER X E4 The host system can read the current contents of the sector buffer of the device by issuing this command Upon receipt of this command the device set...

Page 110: ...it of the Status register Then the device sets the DRQ bit of Status register and clears the BSY bit when the device is ready to receive the data After that 512 bytes of data is transferred from the host and the device writes the data to the sector buffer then generates an interrupt At command issuance I O registers setting contents 1F7H CM 1 1 1 0 1 0 0 0 1F6H DH DV xx 1F5H CH 1F4H CL 1F3H SN 1F2...

Page 111: ...wn function means that the device automatically enters the standby mode after a certain period of time When the device enters the idle mode the timer starts countdown If any command is not issued while the timer is counting down the device automatically enters the standby mode If any command is issued while the timer is counting down the timer is initialized and the command is executed The timer r...

Page 112: ... the Status register and enters the idle mode Then the device clears the BSY bit and generates an interrupt This command does not support the automatic power down function At command issuance I O registers setting contents 1F7H CM X 95 or X E1 1F6H DH DV xx 1F5H CH 1F4H CL 1F3H SN 1F2H SC 1F1H FR xx xx xx xx xx At command completion I O registers contents to be read 1F7H ST Status information 1F6H...

Page 113: ... the Sector Count register is 0 the automatic power down function is disabled Under the standby mode the spindle motor is stopped Thus when the command involving a seek such as the READ SECTOR s command is received the device processes the command after driving the spindle motor At command issuance I O registers setting contents 1F7H CM X 96 or X E2 1F6H DH DV xx 1F5H CH 1F4H CL 1F3H SN 1F2H SC 1F...

Page 114: ...ceipt of this command the device sets the BSY bit of the Status register and enters the sleep mode The device then clears the BSY bit and generates an interrupt The device generates an interrupt even if the device has not fully entered the sleep mode In the sleep mode the spindle motor is stopped and the ATA interface section is inactive All I O register outputs are in high impedance state The onl...

Page 115: ...is command The host system can confirm the power save mode of the device by analyzing the contents of the Sector Count and Sector Number registers The device sets the BSY bit and sets the following register value After that the device clears the BSY bit and generates an interrupt Power save mode Sector Count register Sector Number register During moving to standby mode Standby mode During returnin...

Page 116: ...pecified in the FR register is supported the Aborted Command error is posted It is necessary for the host to set the keys CL 4Fh and CH C2h in the CL and CH registers prior to issuing this command If the keys are set incorrectly the Aborted Command error is posted When the failure prediction feature is disabled the Aborted Command error is posted in response to subcommands other than SMART Enable ...

Page 117: ...ives this subcommand it asserts the BSY bit enables or disables the automatic saving feature then clears the BSY bit X D3 SMART Save Attribute Values When the device receives this subcommand it asserts the BSY bit saves device attribute value data then clears the BSY bit X D4 SMART Execute off line Immediate Execute Self Test The device that received these subcommands shall execute off line data c...

Page 118: ... this subcommand it asserts the BSY bit enables the failure prediction feature then clears the BSY bit X D9 SMART Disable Operations This subcommand disables the failure prediction feature The setting is maintained even when the device is turned off and then on When the device receives this subcommand it asserts the BSY bit disables the failure prediction feature then clears the BSY bit X DA SMART...

Page 119: ...or the device is nearing the end of it life In this case the host recommends that the user quickly backs up the data At command issuance I O registers setting contents 1F7H CM 1 0 1 1 0 0 0 0 1F6H DH DV xx 1F5H CH 1F4H CL 1F3H SN 1F2H SC 1F1H FR Key C2h Key 4Fh xx xx Subcommand At command completion I O registers setting contents 1F7H ST Status information 1F6H DH DV xx 1F5H CH 1F4H CL 1F3H SN 1F2...

Page 120: ...Reserved Each attribute format is the same as 1st attribute 16A Off line data collection status 7 16B Self Test execution status byte 8 16C 16D Off line data collection executing times sec 16E Reserved 16F Off line data collection Off line data collection capability 9 170 171 SMART capability flag 10 172 Drive error logging capability 11 173 Self Test failure checkpoint 174 Quick Test completion t...

Page 121: ... 15 05 06 07 to 0C 0D 1st drive threshold Reserved 0E to 169 2nd to 30th drive threshold Reserved Each threshold format is the same as 1st drive threshold 16A to 17B Reserved 17C to 1FE Vendor unique 1FF Check sum 1 Data structure revision number It indicates the revision number of device attribute and warranty failure threshold They will have the same Data structure revision number ...

Page 122: ... the spindle motor is activated 5 Number of alternative sectors 6 Read channel margin Not supported 7 Seek error rate 8 Seek time performance 9 Power on time 10 Number of retries made to activate the spindle motor 11 Number of retries to calibration 12 Number of turn on off times 13 to 193 Reserved 194 HDA Temperature 195 to 198 Reserved 199 Ultra ATA CRC Error Rate 200 Write error rate 201 to 255...

Page 123: ...o 1 it indicates the attribute shall be collected and saved even if the failure prediction feature is disabled 6 to 15 Reserved bits 4 Normalized attribute value The current attribute value is the normalized raw attribute data The value varies between 01h and 64h The closer the value gets to 01h the higher the possibility of a failure The device compares the attribute values with thresholds When t...

Page 124: ...utomatic off line data collection function is enabled 8 Self Test execution status byte 16Bh Bit 0 3 Self Test remain time The values in these bits indicate the remaining percentage 0 90 of Self Test until completion by 0h 9h Bit 4 7 Self Test execution status 00h Self Test has been completed normally Otherwise Self Test has not performed 01h Self Test has been interrupted by host 02h Self Test ha...

Page 125: ...it is set to 1 it indicates the attribute data is saved to the media before the drive enters power save mode 1 If this bit is set to 1 it indicates the device saves the attribute automatically according to fixed operation 2 15 Reserved bits 11 Drive error logging capability 172h Bit Description 0 If this bit is set to 1 it indicates the drive error logging is supported 1 to 15 Reserved bits 12 Qui...

Page 126: ...5 11 Log directory data structure Address Hex Description 00 to 01 SMART logging version 02 Number of sectors for Log Sector Address 01h 03 to 0B Reserved 0C Number of sectors for Log Sector Address 06h 0D to FF Reserved 100 Number of sectors 101 Address 80h Reserved 102 to 13F Address 81h to Address 9Fh Data format is the same at Address 100 to 101 140 to 1FF Reserved ...

Page 127: ...8 Drive Head register 39 Command register 3A to 3D Command data structure Elapsed time from power on ms 3E Reserved 3F Error register 40 Sector count register 41 Sector number register 42 Cylinder low register 43 Cylinder high register 44 Drive Head register 45 Status register 46 to 58 Vendor unique 59 State 5A 5B Error log data stucture 1 Error data structure Cumulative elapsed time h 5C to 1C3 E...

Page 128: ...t Execution Status Refer to explanation of Attribute Byte 16Bh Self Test Index When it is 00h it means that Self Test has not been performed Check Sum Twos complement of the lower byte obtained by adding 511 byte data one by at a time from the beginning 16 Command data structure It indicates that the device has received structure of the command when the drive occurs the error 17 Error data structu...

Page 129: ... command may take longer than 30 s to complete If the command is not supported the device shall set the ABRT bit to one An unrecoverable error encountered during execution of writing data results in the termination of the command and the Command Block registers contain the sector address of the sector where the first unrecoverable error occurred The sector is removed from the cache Subsequent FLUS...

Page 130: ...ssword the master password is retained To recover the master password issue the SECURITY SET PASSWORD command and reset the user password If the user password or master password transferred from the host does not match the Aborted Command error is returned Issuing this command while in LOCKED MODE or FROZEN MODE returns the Aborted Command error The section about the SECURITY FREEZE LOCK command d...

Page 131: ...ion 1F6H DH DV xx 1F5H CH 1F4H CL 1F3H SN 1F2H SC 1F1H ER xx xx xx xx Error information 31 SECURITY ERASE PREPARE F3h The SECURITY ERASE UNIT command feature is enabled by issuing the SECURITY ERASE PREPARE command and then the SECURITY ERASE UNIT command The SECURITY ERASE PREPARE command prevents data from being erased unnecessarily by the SECURITY ERASE UNIT command Issuing this command during ...

Page 132: ...e 512 byte data shown in Table 5 14 to the device The device compares the user password or master password in the transferred data with the user password or master password already set The device erases user data invalidates the user password and releases the lock function if the passwords are the same Although this command invalidates the user password the master password is retained To recover t...

Page 133: ...evice into FROZEN MODE The following commands used to change the lock function return the Aborted Command error if the device is in FROZEN MODE SECURITY SET PASSWORD SECURITY UNLOCK SECURITY DISABLE PASSWORD SECURITY ERASE PREPARE SECURITY ERASE UNIT FROZEN MODE is canceled when the power is turned off If this command is reissued in FROZEN MODE the command is completed and FROZEN MODE remains unch...

Page 134: ...x xx At command completion I O registers contents to be read 1F7H ST Status information 1F6H DH DV xx 1F5H CH 1F4H CL 1F3H SN 1F2H SC 1F1H ER xx xx xx xx Error information 34 SECURITY SET PASSWORD F1h This command enables a user password or master password to be set The host transfers the 512 byte data shown in Table 5 15 to the device The device determines the operation of the lock function accor...

Page 135: ...ssword is saved as a new user password The lock function is enabled after the device is turned off and then on LOCKED MODE can be canceled using the user password or the master password already set Master High The specified password is saved as a new master password The lock function is not enabled User Maximum The specified password is saved as a new user password The lock function is enabled aft...

Page 136: ...dy set If the passwords are the same LOCKED MODE is canceled Otherwise the Aborted Command error is returned If the security level in LOCKED MODE is set to the highest level the Aborted Command error is always returned When the user password is selected The password is compared with the user password already set If the passwords are the same LOCKED MODE is canceled Otherwise the Aborted Command er...

Page 137: ...s information set by this command is reflected in Words 1 54 57 58 60 and 61 of IDENTIFY DEVICE information If an attempt is made to perform a read or write operation for an address beyond the new address space an ID Not Found error will result When SC register bit 0 VV Value Volatile is 1 the value set by this command is held even after power on and the occurrence of a hard reset When the VV bit ...

Page 138: ... DV Max head LBA MSB 1F5H CH 1F4H CL 1F3H SN 1F2H SC 1F1H ER Max cylinder MSB Max LBA Max cylinder LSB Max LBA Max sector Max LBA LSB xx Error information 36 2 SET MAX SET PASSWORD F9 This command requests a transfer of single sector of data from the host and defines the content of this sector of information The password is retained by the device until the next power cycle At command issuance I O ...

Page 139: ... any other Set Max commands except SET MAX UNLOCK and SET MAX FREEZE LOCK are rejected The device remains in this state until a power cycle or the acceptance of A SET MAX UNLOCK or SET MAX FREEZE LOCK command At command issuance I O registers setting contents 1F7H CM 1 1 1 1 1 0 0 1 1F6H DH 1 L 1 DV xx 1F5H CH 1F4H CL 1F3H SN 1F2H SC xx xx xx xx 1F1H FR 0 0 0 0 0 0 1 0 At command completion I O re...

Page 140: ... MAX UNLOCK command shall return command aborted until a power cycle If the password compare matches then the device shall make a transition to the Set_Max_Unlocked state and all SET MAX commands will be accepted At command issuance I O registers setting contents 1F7H CM 1 1 1 1 1 0 0 1 1F6H DH 1 L 1 DV xx 1F5H CH 1F4H CL 1F3H SN 1F2H SC xx xx xx xx 1F1H FR 0 0 0 0 0 0 1 1 At command completion I ...

Page 141: ... 1 L 1 DV xx 1F5H CH 1F4H CL 1F3H SN 1F2H SC 1F1H ER xx xx xx xx Error information 37 READ NATIVE MAX ADDRESS F8 This command posts the maximum address intrinsic to the device which can be set by the SET MAX ADDRESS command Upon receipt of this command the device sets the BSY bit and indicates the maximum address in the DH CH CL and SN registers Then it clears BSY and generates an interrupt At com...

Page 142: ...completion I O registers contents to be read 1F7H ST Status information 1F6H DH DV Max head LBA MSB 1F5H CH 1F4H CL 1F3H SN 1F2H SC 1F1H ER Max cylinder MSB Max LBA Max cylinder LSB Max LBA Max sector Max LBA LSB xx Error information ...

Page 143: ...ERS V V V V IDENTIFY DEVICE V V V V IDENTIFY DEVICE DMA V V V V SET FEATURES V V V V SET MULTIPLE MODE V V V V EXECUTE DEVICE DIAGNOSTIC V FORMAT TRACK V V V V V READ LONG V V V V V WRITE LONG V V V V V READ BUFFER V V V V WRITE BUFFER V V V V IDLE V V V V IDLE IMMEDIATE V V V V STANDBY V V V V STANDBY IMMEDIATE V V V V SLEEP V V V V CHECK POWER MODE V V V V SMART V V V V V FLUSH CACHE V V V V V S...

Page 144: ...rameters to the Features Sector Count Sector Number Cylinder and Device Head registers b The host writes a command code to the Command register c The device sets the BSY bit of the Status register and prepares for data transfer d When one sector or block of data is available for transfer to the host the device sets DRQ bit and clears BSY bit The drive then asserts INTRQ signal e After detecting th...

Page 145: ...lection INTRQ DRQ Min 30 µs 1 Expanded Command f d d e e c b a Command BSY INTRQ DRDY Parameter write DRQ Data transfer Figure 5 2 Read Sector s command protocol Even if the error status exists the drive makes a preparation setting the DRQ bit of data transfer It is up to the host whether data is transferred In other words the host should receive the data of the sector 512 bytes of uninsured dummy...

Page 146: ...requests the data transfer setting in DRQ bit the correct device operation is not guaranteed Transfers dummy data The host should receive 512 byte dummy data or release the DRQ set state by resetting Status read Command BSY INTRQ DRDY Parameter write DRQ Data transfer Figure 5 3 Protocol for command abort 5 4 2 Data transferring commands from host to device The execution of the following commands ...

Page 147: ...ansferring the data of the sector the device clears BSY bit and asserts INTRQ signal If transfer of another sector is requested the drive sets the DRQ bit g After detecting the INTRQ signal assertion the host reads the Status register h The device resets INTRQ the interrupt signal i If transfer of another sector is requested steps d and after are repeated Figure 5 4 shows an example of WRITE SECTO...

Page 148: ...ansfer DRQ bit is set or when the host executes resetting the device correct operation is not guaranteed 5 4 3 Commands without data transfer Execution of the following commands does not involve data transfer between the host and the device RECALIBRATE SEEK READY VERIFY SECTOR S EXECUTE DEVICE DIAGNOSTIC INITIALIZE DEVICE PARAMETERS SET FEATURES SET MULTIPLE MODE IDLE IDLE IMMEDIATE STANDBY STANDB...

Page 149: ...ing for the DMA transfer differs the following point a The host writes any parameters to the Features Sector Count Sector Number Cylinder and Device Head register b The host initializes the DMA channel c The host writes a command code in the Command register d The device sets the BSY bit of the Status register e The device asserts the DMARQ signal after completing the preparation of data transfer ...

Page 150: ... E116 01EN 5 83 Status read Expanded g f e c d a Command BSY INTRQ DRDY Parameter write DRQ Data transfer DRQ Multiword DMA transfer DMACK DMARQ IOR or IOW 0 1 Word n 1 n Figure 5 6 Normal DMA data transfer ...

Page 151: ...s of STROBE are used for data transfers so that the frequency of STROBE is limited to the same frequency as the data The highest fundamental frequency on the cable shall be 16 67 million transitions per second or 8 33 MHz the same as the maximum frequency for PIO Mode 4 and DMA Mode 2 Words in the IDENTIFY DEVICE data indicate support of the Ultra DMA feature and the Ultra DMA Modes the device is ...

Page 152: ...ts 1 The host shall keep DMACK in the negated state before an Ultra DMA burst is initiated 2 The device shall assert DMARQ to initiate an Ultra DMA burst After assertion of DMARQ the device shall not negate DMARQ until after the first negation of DSTROBE 3 Steps 3 4 and 5 may occur in any order or at the same time The host shall assert STOP 4 The host shall negate HDMARDY 5 The host shall negate C...

Page 153: ... DD 15 0 until at least tDVH after generating a DSTROBE edge to latch the data 4 The device shall repeat steps 1 2 and 3 until the data transfer is complete or an Ultra DMA burst is paused whichever occurs first 5 5 3 3 Pausing an Ultra DMA data in burst The following steps shall occur in the order they are listed unless otherwise specifically allowed see 5 6 3 4 and 5 6 3 2 for specific timing re...

Page 154: ...ated 3 The device shall release DD 15 0 no later than tAZ after negating DMARQ 4 The host shall assert STOP within tLI after the device has negated DMARQ The host shall not negate STOP again until after the Ultra DMA burst is terminated 5 The host shall negate HDMARDY within tLI after the device has negated DMARQ The host shall continue to negate HDMARDY until the Ultra DMA burst is terminated Ste...

Page 155: ... device shall stop generating DSTROBE edges within tRFS of the host negating HDMARDY 4 If the host negates HDMARDY within tSR after the device has generated a DSTROBE edge then the host shall be prepared to receive zero or one additional data words If the host negates HDMARDY greater than tSR after the device has generated a DSTROBE edge then the host shall be prepared to receive zero one or two a...

Page 156: ...assert DIOR CS0 CS1 DA2 DA1 or DA0 until at least tACK after negating DMACK 5 5 4 Ultra DMA data out commands 5 5 4 1 Initiating an Ultra DMA data out burst The following steps shall occur in the order they are listed unless otherwise specifically allowed see 5 6 3 7 and 5 6 3 2 for specific timing requirements 1 The host shall keep DMACK in the negated state before an Ultra DMA burst is initiated...

Page 157: ...an tCYC for the selected Ultra DMA Mode The host shall not generate two rising or falling HSTROBE edges more frequently than 2 tCYC for the selected Ultra DMA mode 3 The host shall not change the state of DD 15 0 until at least tDVH after generating an HSTROBE edge to latch the data 4 The host shall repeat steps 1 2 and 3 until the data transfer is complete or an Ultra DMA burst is paused whicheve...

Page 158: ...c timing requirements 1 The host shall initiate termination of an Ultra DMA burst by not generating HSTROBE edges 2 The host shall assert STOP no sooner than tSS after it last generated an HSTROBE edge The host shall not negate STOP again until after the Ultra DMA burst is terminated 3 The device shall negate DMARQ within tLI after the host asserts STOP The device shall not assert DMARQ again unti...

Page 159: ...s generated an HSTROBE edge then the device shall be prepared to receive zero or one additional data words If the device negates DDMARDY greater than tSR after the host has generated an HSTROBE edge then the device shall be prepared to receive zero one or two additional data words The additional data words are a result of cable round trip delay and tRFS timing for the host 5 The device shall negat...

Page 160: ...lculated for the return of STROBE to the asserted state after the Ultra DMA burst termination request has been acknowledged e At the end of any Ultra DMA burst the host shall send the results of its CRC calculation function to the device on DD 15 0 with the negation of DMACK f The device shall then compare the CRC data from the host with the calculated value in its own CRC calculation function If ...

Page 161: ...ng table describes recommended values for series termination at the host and the device Table 5 18 Recommended series termination for Ultra DMA Signal Host Termination Device Termination DIOR HDMARDY HSTROBE 22 ohm 82 ohm DIOW STOP 22 ohm 82 ohm CS0 CS1 33 ohm 82 ohm DA0 DA1 DA2 33 ohm 82 ohm DMACK 22 ohm 82 ohm DD15 through DD0 33 ohm 33 ohm DMARQ 82 ohm 22 ohm INTRQ 82 ohm 22 ohm IORDY DDMARDY D...

Page 162: ...er selection setup time for DIOR DIOW 25 ns t2 Pulse width of DIOR DIOW 70 ns t2i Recovery time of DIOR DIOW 25 ns t3 Data setup time for DIOW 20 ns t4 Data hold time for DIOW 10 ns t5 Time from DIOR assertion to read data available 50 ns t6 Data hold time for DIOR 5 ns t9 Data register selection hold time for DIOR DIOW 10 ns t10 Time from DIOR DIOW assertion to IORDY low level 35 ns t11 Time from...

Page 163: ...parameter Min Max Unit t0 Cycle time 120 ns tC Delay time from DMACK assertion to DMARQ negation 35 ns tD Pulse width of DIOR DIOW 70 ns tE Data setup time for DIOR 30 ns tF Data hold time for DIOR 5 ns tG Data setup time for DIOW 20 ns tH Data hold time for DIOW 10 ns tI DMACK setup time for DIOR DIOW 0 ns tJ DMACK hold time for DIOR DIOW 5 ns tK Continuous time of high level for DIOR DIOW 25 ns ...

Page 164: ...an Ultra DMA data in burst 5 6 3 2 contains the values for the timings for each of the Ultra DMA Modes Note The definitions for the STOP HDMARDY and DSTROBE signal lines are not in effect until DMARQ and DMACK are asserted Figure 5 10 Initiating an Ultra DMA data in burst DMARQ device DMACK host STOP host HDMARDY host DSTROBE device DD 15 0 DA0 DA1 DA2 CS0 CS1 tUI tENV tFS tENV tZAD tFS tZAD tDVH ...

Page 165: ...VS 70 48 31 20 6 7 4 8 Data valid setup time at sender from data valid until STROBE edge 3 tDVH 6 2 6 2 6 2 6 2 6 2 4 8 Data valid hold time at sender from STROBE edge until data may become invalid 3 tCS 15 10 7 7 5 5 CRC word setup time at device 2 tCH 5 5 5 5 5 5 CRC word hold time device 2 tCVS 70 48 31 20 6 7 10 CRC word valid setup time at host from CRC valid until DMACK negation 3 tCVH 6 2 6...

Page 166: ...of STOP when sender terminates a burst 1 Except for some instances of tMLI that apply to host signals only the parameters tUI tMLI and tLI indicate sender to recipient or recipient to sender interlocks i e one agent either sender or recipient is waiting for the other agent to respond with a signal before proceeding tUI is an unlimited interlock that has no maximum time value tMLI is a limited time...

Page 167: ...HIC 9 9 9 9 9 6 Sender IC data valid hold time from STROBE edge until data may become invalid 2 1 The correct data value shall be captured by the recipient given input data with a slew rate of 0 4 V ns rising and falling and the input STROBE with a slew rate of 0 4 V ns rising and falling at tDSIC and tDHIC timing as measured through 1 5V 2 The parameters tDVSIC and tDVHIC shall be met for lumped ...

Page 168: ...e that cable setting time as well as cable propagation delay shall not allow the data signals to be considered stable at the host until some time after they are driven by the device Figure 5 11 Sustained Ultra DMA data in burst DSTROBE at device DD 15 0 at device DSTROBE at host DD 15 0 at host t2CYC tCYC tDVS tDVSIC tDVH tDVHIC tDS tDSIC tDH tDHIC t2CYC tCYC tDVS tDVSIC tDVH tDVHIC tDH tDHIC tDH ...

Page 169: ... The host may assert STOP to request termination of the Ultra DMA burst no sooner than tRP after HDMARDY is negated 2 After negating HDMARDY the host may receive zero one two or three more data words from the device Figure 5 12 Host pausing an Ultra DMA data in burst tRP tRFS DMARQ device DMACK host STOP host HDMARDY host DSTROBE device DD 15 0 device ...

Page 170: ... Modes Note The definitions for the STOP HDMARDY and DSTROBE signal lines are no longer in effect after DMARQ and DMACK are negated Figure 5 13 Device terminating an Ultra DMA data in burst DMARQ device DMACK host DD 15 0 HDMARDY host DSTROBE device STOP host DA0 DA1 DA2 CS0 CS1 tMLI tLI tLI tLI tACK tACK tIORDYZ tSS tZAH tAZ tCVS tCVH CRC tACK ...

Page 171: ...des Note The definitions for the STOP HDMARDY and DSTROBE signal lines are no longer in effect after DMARQ and DMACK are negated Figure 5 14 Host terminating an Ultra DMA data in burst DMARQ device tLI tMLI tRP tZAH tAZ tRFS tLI tMLI tCVS tCVH tACK tACK tACK tIORDYZ CRC DA0 DA1 DA2 CS0 CS1 DMACK host STOP host HDMARDY host DSTROBE device DD 15 0 ...

Page 172: ...a DMA Modes Note The definitions for the STOP DDMARDY and HSTROBE signal lines are not in effect until DMARQ and DMACK are asserted Figure 5 15 Initiating an Ultra DMA data out burst DMARQ device DMACK host STOP host DDMARDY device HSTROBE host DD 15 0 host DA0 DA1 DA2 CS0 CS1 tUI tACK tENV tZIORDY tUI tLI tACK tACK tDVH tDVS tDZFS ...

Page 173: ...e that cable setting time as well as cable propagation delay shall not allow the data signals to be considered stable at the device until some time after they are driven by the host Figure 5 16 Sustained Ultra DMA data out burst HSTROBE at host HSTROBE at device DD 15 0 at host DD 15 0 at device t2CYC tCYC tCYC t2CYC tDVH tDVHIC tDVS tDVSIC tDVS tDVSIC tDVH tDVHIC tDH tDHIC tDS tDSIC tDH tDHIC tDS...

Page 174: ... The device may negate DMARQ to request termination of the Ultra DMA burst no sooner than tRP after DDMARDY is negated 2 After negating DDMARDY the device may receive zero one two or three more data words from the host Figure 5 17 Device pausing an Ultra DMA data out burst DMARQ device DMACK host STOP host DDMARDY device HSTROBE host DD 15 0 host tRP tRFS ...

Page 175: ...MA Modes Note The definitions for the STOP DDMARDY and HSTROBE signal lines are no longer in effect after DMARQ and DMACK are negated Figure 5 18 Host terminating an Ultra DMA data out burst DMARQ device DMACK host STOP host DDMARDY device HSTROBE host DD 15 0 host tLI tLI tSS tLI tMLI tACK tIORDYZ tACK tACK tCVH tCVS CRC DA0 DA1 DA2 CS0 CS1 ...

Page 176: ...Modes Note The definitions for the STOP DDMARDY and HSTROBE signal lines are no longer in effect after DMARQ and DMACK are negated Figure 5 19 Device terminating an Ultra DMA data out burst DMARQ device DMACK host STOP host DDMARDY device HSTROBE host DD 15 0 host DA0 DA1 DA2 CS0 CS1 tLI tLI tRP tRFS tMLI tMLI tCVS tCVH tIORDYZ tACK tACK tACK CRC ...

Page 177: ...set 2 Master and slave devices are present 2 drives configuration tP Clear Reset Slave device Master device tN DASP PDIAG BSY BSY DASP tQ tR tS Symbol Timing parameter Min Max Unit tM Pulse width of RESET 25 µs tN Time from RESET negation to BSY set 400 ns tP Time from RESET negation to DASP or DIAG negation 1 ms tQ Self diagnostics execution time 30 s tR Time from RESET negation to DASP assertion...

Page 178: ...Address Translation 6 3 Power Save 6 4 Defect Management 6 5 Read Ahead Cache 6 6 Write Cache 6 1 Device Response to the Reset This section describes how the PDIAG and DASP signals responds when the power of the IDD is turned on or the IDD receives a reset or diagnostic command ...

Page 179: ...vice is connected After the slave device device 1 releases its own power on reset state the slave device shall report its presence and the result of power on diagnostics to the master device as described below DASP signal Asserted within 400 ms and negated after the first command is received from the host or within 31 seconds or after executing software reset which ever comes first PDIAG signal Ne...

Page 180: ...e master device recognizes that no slave device is connected After the slave device receives the hardware reset the slave device shall report its presence and the result of the self diagnostics to the master device as described below DASP signal Asserted within 400 ms and negated after the first command is received from the host or within 31 seconds or after executing software reset which ever com...

Page 181: ... presence and the result of the self diagnostics to the master device as described below PDIAG signal negated within 1 ms and asserted within 30 seconds then negated within 31 seconds When the IDD is set to a slave device the IDD asserts the DASP signal when negating the PDIAG signal and negates the DASP signal when asserting the PDIAG signal Max 31 sec Max 30 sec Max 1 ms If the slave device is p...

Page 182: ...CE DIAGNOSTIC command it shall report the result of the self diagnostics to the master device as described below PDIAG signal negated within 1 ms and asserted within 5 seconds then negated within 6 seconds When the IDD is set to a slave device the IDD asserts the DASP signal when negating the PDIAG signal and negates the DASP signal when asserting the PDIAG signal Max 6 sec Max 5 sec Max 1 ms If t...

Page 183: ...ault translation mode The parameters in Table 6 1 are called BIOS specification Table 6 1 Default parameters MPG3204AH E MPG3307AH E MPG3409AH E Number of cylinders 16 383 Number of head 16 Number of sectors track 63 Formatted capacity GB 20 49 30 74 40 99 As long as the formatted capacity of the IDD does not exceed the value shown on Table 6 1 the host can freely specify the number of cylinders h...

Page 184: ...the consecutive logical sector from the last sector of the current physical sector Figure 6 5 shows an example assuming there is no track skew LS 63 LH2 LH1 LH0 LS 2 LS 1 LS 1 736 735 734 190 189 64 63 62 3 2 21 20 1 1 127 126 Physical sector Physical sector ex Zone 0 Physical parameter Physical sector 1 to 736 Specification of INITIALIZE DEVICE PARAMETERS command Logical head LH 0 to 15 Logical s...

Page 185: ...BA 0 3 2 1 Physical sector ex Zone 0 Physical parameter Physical sector 1 to 736 Physical cylinder 0 Physical head 0 LBA 1467 LBA 1466 LBA 1465 LBA 1464 3 2 1 Physical cylinder 0 Physical head 1 LBA 738 LBA 737 LBA 736 736 735 734 733 736 735 Figure 6 6 Address translation example in LBA mode 6 3 Power Save The host can change the power consumption state of the device by issuing a power command to...

Page 186: ...without Seek or Write or Read is issued 3 Standby mode In this mode the VCM circuit is turned off and the spindle motor is stopped The device can receive commands through the interface However if a command with disk access is issued response time to the command under the standby mode takes longer than the active or Idle mode because the access to the disk medium cannot be made immediately The driv...

Page 187: ...ion A SLEEP command is issued Issued commands are invalid ignored in this mode 6 3 2 Power commands The following commands are available as power commands IDLE IDLE IMMEDIATE STANDBY STANDBY IMMEDIATE SLEEP CHECK POWER MODE 6 4 Defect Management Defective sectors of which the medium defect location is registered in the system space are replaced with spare sectors in the formatting at the factory s...

Page 188: ...p processing A defective sector is not used and is skipped and a logical sector address is assigned to the subsequent normal sector physically adjacent sector to the defective sector When defective sector is present the sector slip processing is performed in the formatting Figure 6 7 shows an example where physical sector 5 is defective on head 0 in cylinder 0 2 1 Index Head 0 Defective sector If ...

Page 189: ...cylinder instead of sector 5 When an access request to sectors next to sector 5 is specified the device seeks to cylinder 0 head 0 and continues the processing Defective sector is assigned to unassigned sector unused Sector logical Sector physical Alternate cylinder 2 1 4 3 6 7 736 735 Figure 6 8 Alternate cylinder assignment 3 Automatic alternate assignment The device performs the automatic assig...

Page 190: ...disk medium The host can access the data at higher speed 6 5 1 Data buffer configuration The device has a 2MB data buffer The buffer is used by divided into two and other commands parts for MPU work for read cache of read commands and other commands see Figure 6 9 for MPU work 80 KB 81 920 bytes 2 048 KB 2 097 152 bytes For R W command 1 968 KB 2 015 232 bytes Figure 6 9 Data buffer configuration ...

Page 191: ...caching operation The following data are object of caching operation 1 Read ahead data read from the disk medium in the data buffer after completion of the command that are object of caching operation 2 Data transferred to the host system once by requesting with the command that are object of caching operation When the sector data requested by the host does not finish storing in the buffer for rea...

Page 192: ...ment Segment only for read DAP HAP 2 Transfers the requested data that already read to the host system with reading the requested data from the disk media Read requested data Stores the read requested data upto this point Empty area DAP HAP 3 After reading the requested data and transferring the requested data to the host system had been completed the disk drive continues to read till a certain am...

Page 193: ... DAP and HAP to the sequential address of the last read command and reads the requested data Empty data Mis hit data 2 The disk drive transfers the requested data that is already read to the host system with reading the requested data Requested data DAP HAP Mis hit data Empty data 3 After completion of the reading and transferring the requested data to the host system the disk drive performs the r...

Page 194: ...sferring data to the host system 1 In the case that the contents of buffer is as follows at receiving a read command Start LBA Last LBA DAP HAP Completion of transferring requested data Hit data Read ahead data 2 The disk drive starts the read ahead operation to the empty area that becomes vacant by data transfer at the same time as the disk drive starts transferring hit data DAP HAP Hit data New ...

Page 195: ...ws for example and the previous command is a sequential read command the disk drive sets the HAP to the address of which the hit data is stored HAP set to hit position for data transfer Last position at previous read command Last position at previous read command Cache data Full hit data Cache data 2 The disk drive transfers the requested data but does not perform the read ahead operation stopped ...

Page 196: ...tored and sets the DAP to the address just after the partially hit data HAP DAP Partially hit data Lack data 2 The disk drive starts transferring partially hit data and reads lack data from the disk media at the same time stopped HAP Requested data to be transferred DAP Partially hit data Lack data ...

Page 197: ...vious command had been completed the latency time occurs to search the target sector If the received command is not a sequential write the drive receives data of sectors requested by the host system as same as sequential write The drive generates the interrupt of command complete after completion of data transfer requested by the host system Received data is processed after completion of the write...

Page 198: ...n is enabled the transferred data from the host by the WRITE SECTOR S is not completely written on the disk medium at the time that the interrupt of command complete is generated When the unrecoverable error occurs during the write operation the command execution is stopped Then when the drive receives the next command it generates an interrupt of abnormal end However an interrupt of abnormal end ...

Page 199: ...A Almagro 40 28010 Madrid SPAIN TEL 34 1 581 8100 FAX 34 1 581 8125 FUJITSU AUSTRALIA LIMITED 2 Julius Avenue Cnr Delhi Road North Ryde N S W 2113 AUSTRALIA TEL 61 2 9776 4555 FAX 61 2 9776 4556 FUJITSU HONG KONG LTD 10 F Lincoln House 979 King s Road Taikoo Place Island East HONG KONG TEL 852 2827 5780 FAX 852 2827 4724 FUJITSU KOREA LTD Coryo Finance Center Bldg 23 6 YoulDo Dong Young DungPo Gu ...

Page 200: ...of this publication What is your occupation Your other comments may be entered here Please be specific and give page paragraph and line number references where applicable Your Name Return Address Sales Operating Installing Maintaining Learning Reference Fair Poor Very Good Good Very Poor Fully covered Well Illustrated Thank you for your interest Please send this sheet to one of the addresses in a ...

Page 201: ......