Specifications
2-6
C141-E237
(2)
Mean Time To Repair (MTTR)
MTTR is the average time taken by a well-trained service mechanic to diagnose and repair a drive
malfunction. The drive is designed for a MTTR of 30 minutes or less.
(3) Service
life
The service life under suitable conditions and treatment is as follows.
The service life is depending on the environment temperature. Therefore, the user must design the
system cabinet so that the average DE surface temperature is as low as possible.
•
DE surface temperature: 40°C or less
5 years
•
DE surface temperature: 41°C to 45°C
4.5 years
•
DE surface temperature: 46°C to 50°C
4 years
•
DE surface temperature: 51°C to 55°C
3.5 years
•
DE surface temperature: 56°C to 60°C
3 years
•
DE surface temperature: Exceeding 60°C Without warranty
(Keep the DE surface temperature 60
°
C or less.)
Even if the HDDs are used intermittently, the longest service life is 5 years.
Note:
The "average DE surface temperature" means the average temperature at the DE surface
throughout the year when the HDDs are operating.
(4)
Data security at power failure
Integrity of the data on the disk is guaranteed against all forms of DC power failure except on blocks
where a write operation is being performed. The above does not applied to formatting disks or
assigning alternate blocks.
Summary of Contents for MAX3036RC SERIES
Page 1: ...C141 E237 01EN MAX3147RC MAX3073RC MAX3036RC HARD DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Page 10: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 92: ...This page is intentionally left blank ...
Page 93: ......
Page 94: ......