C141-E035-02EN
5 - 8
IMPORTANT
1.
Set the SCSI ID so that there are no duplicates between SCSI devices
on the same SCSI bus.
2.
The priority of SCSI bus use in ARBITRATION phase is determined by
SCSI ID as follows:
7 > 6 > 5 > 4 > 3 > 2 > 1 > 0 > 15 > 14 > 13 > 12 > 11 > 10 > 9 > 8
5.3.2
Each mode setting
(1)
Setting terminal power supply
Refer to Table 5.2 for controlling the supply of power from the drive to the SCSI terminal
resistance power source (TERMPOW). However, this setting may not be used with SCA2
type 16 bit-SCSI (MAx3xxxSC). For information on MAx3xxxSP, refer to Figures 5.2 and
5.3.
Table 5.2
Setting SCSI terminal power supply (single-ended 16-bit SCSI model: MAx3xxxSP)
Supply on/off of SCSI terminating resistor power from IDD
CN6 1-2
Supply off
Open
Supply on
Short (*1)
*1 Setting at factory shipment
(2)
Motor start mode
Set how to control the starting of the IDD spindle motor according to Table 5.3. This setting
only determines the operation mode when the power supply is turned on or the microcode is
downloaded. In both modes, stopping or restarting the spindle motor can be controlled by
specifying the START/STOP UNIT command.
This setting is not provided for SCA2 type 16-bit SCSI model (MAx3xxxSC).
For information on MAx3xxxSP, refer to Figures 5.2 and 5.3.
Table 5.3
Motor start mode setting (single-ended 16-bit SCSI model: MAx3xxxSP)
Start timing of the spindle motor
CN6 3-4
Starting of the motor is controlled with the START/STOP UNIT command.
Open
The motor is started immediately after the power supply is turned on or the
microcode is downloaded.
Short (*1)
*1 Setting at factory shipment
Refer to Chapter 3 of the SCSI Logical Interface Specifications for details of the
START/STOP UNIT command.
Summary of Contents for MAA3182
Page 3: ......
Page 21: ...C141 E035 02EN 1 6 Figure 1 2 MAA31xxSP outer view Figure 1 3 MAB30xxSC outer view ...
Page 27: ......
Page 35: ......
Page 53: ...C141 E035 02EN 4 2 Figure 4 1 External dimensions MAA31xxSC ...
Page 54: ...C141 E035 02EN 4 3 Figure 4 2 External dimensions MAA31xxSP ...
Page 55: ...C141 E035 03EN 4 4 Figure 4 3 External dimensions MAB30xxSC MAC30xxSC ...
Page 56: ...C141 E035 03EN 4 5 Figure 4 4 External dimensions MAB30xxSP MAC30xxSP ...
Page 68: ...C141 E035 02EN 4 17 Figure 4 20 External operator panel connector CN7 ...
Page 85: ...C141 E035 02EN 5 6 Figure 5 3 Setting terminals MAx3xxxSP ...
Page 115: ......
Page 119: ......
Page 123: ......
Page 135: ......
Page 139: ......
Page 140: ......