C141-E035-02EN
4 - 6
4.1.2
Mounting
The permissible orientations of the IDD are shown in Figure 4.5, and the tolerance of the angle
is
±
5° from the horizontal plane.
Figure 4.5
IDD orientation
4.1.3
Notes on mounting
(1)
Mounting frame structure
To guarantee integrity of the IDD disk enclosure (DE) insulation once mounted on the frame
inside the system, special attention must be given to the note below.
Note:
Generally, SG and FG are connected at one point in the system enclosure. Therefore, use
following procedure to maintain the insulation when mounting the IDD.
a)
Use the frame with an embossed structure or the like to avoid contact between the DE
base and FG. Mount the IDD with making a gap of 2.5 mm or more between the IDD
and the frame of the system.
b)
As shown in Figure 4.6, the inward projection of the screw from the IDD frame wall
at the corner must be 4 mm or less.
Direction of
gravity
(a) Horizontal –1 (b) Horizontal –2 (c) Vertical –1
(d) Vertical –2 (e) Upright mounting –1 (f) Upright mounting –2
Summary of Contents for MAA3182
Page 3: ......
Page 21: ...C141 E035 02EN 1 6 Figure 1 2 MAA31xxSP outer view Figure 1 3 MAB30xxSC outer view ...
Page 27: ......
Page 35: ......
Page 53: ...C141 E035 02EN 4 2 Figure 4 1 External dimensions MAA31xxSC ...
Page 54: ...C141 E035 02EN 4 3 Figure 4 2 External dimensions MAA31xxSP ...
Page 55: ...C141 E035 03EN 4 4 Figure 4 3 External dimensions MAB30xxSC MAC30xxSC ...
Page 56: ...C141 E035 03EN 4 5 Figure 4 4 External dimensions MAB30xxSP MAC30xxSP ...
Page 68: ...C141 E035 02EN 4 17 Figure 4 20 External operator panel connector CN7 ...
Page 85: ...C141 E035 02EN 5 6 Figure 5 3 Setting terminals MAx3xxxSP ...
Page 115: ......
Page 119: ......
Page 123: ......
Page 135: ......
Page 139: ......
Page 140: ......