Error Codes and Messages
If the drive detects a permanent error, it will display the error code on the SCD
and flash the Amber Fault status light (Green Ready/Activity status light will be
Off).
●
Make note of the error code displaying on the SCD prior to removing a
cartridge or clearing the SCD error code.
●
If an error occurred with a cartridge in the drive, push the Unload Button to
eject the cartridge.
Error
Code
Cause and Action
"0"
No error occurred and no action is required.
This code displays
when diagnostics have finished running and no error occurred.
I
The Single-character Display is blank during normal
operation of the tape drive.
"1"
Temperature problem.
The tape drive detected that the
recommended operating temperature was exceeded. Perform one
or more of the following actions:
●
Ensure that the cooling fan is rotating and is quiet. If not, refer
to your enclosure documentation.
●
Remove any blockage that prevents air from flowing freely
through the tape drive.
●
Ensure that the operating temperature and airflow is within the
specified range.
Clear the error code by power cycling the tape drive. If the
operating temperature and airflow are within the specified range,
and the problem persists, contact your support partner.