Disassembly Instruction
LIFEBOOK E733
Page 10 of 32
partners.ts.fujitsu.com
Removing the upper assy
Preliminary steps required:
■
Removing the battery
■
Removing the keyboard
■
Remove the ODD
►
Remove the eight screws (yellow circles).
►
Remove the two screws (red circles).
►
Disconnect the cables (red circles).
►
Remove both screws (yellow circles).
[#
►