background image

SAFETY PRECAUTIONS

If ANY of the following conditions occurs, turn off your unit immediately!

The power cord is damaged or abnormally warm

You smell a burning odor

The unit emits loud or abnormal sounds

A power fuse blows or the circuit breaker frequently trips

Water or other objects fall into or out of the unit

DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED SERVICE PROVIDER 
IMMEDIATELY!

Common Issues

The following problems are not a malfunction and in most situations will not require repairs.

Issue

Possible Causes

Unit does not turn 
on when pressing 
ON/OFF button

The Unit has a 3-minute protection feature that prevents the 
unit from overloading. The unit cannot be restarted within 
three minutes of being turned off.

The unit may change its setting to prevent frost from forming 
on the unit. Once the temperature increases, the unit will start 
operating in the previously selected mode again.

The set temperature has been reached, at which point the 
unit turns off the compressor. The unit will continue operating 
when the temperature fluctuates again.

The indoor unit 
emits white mist

In humid regions, a large temperature difference between the 
room’s air and the conditioned air can cause white mist.

Both the indoor 
and outdoor units 
emit white mist

When the unit restarts in HEAT mode after defrosting, white 
mist may be emitted due to moisture generated from the 
defrosting process.

Troubleshooting

4        

Tr

oubleshooting

The unit changes 
from COOL/HEAT 
mode to FAN 
mode

Page   

14

Summary of Contents for KLWA Series

Page 1: ...ANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference Owner s Manual ON OFF TEMP TIMER ON TIMER OFF MODE FAN SLEEP SWING DIRECT TURBO CLEAN LED FOLLOW SILENCE FP ...

Page 2: ... 04 Unit Specifications and Features 0 Table of Contents Owner s Manual 0 1 SAFETY FIRST Manual Operation Without Remote 2 ON OFF TEMP TIMER ON TIMER OFF MODE FAN SLEEP SWING DIRECT TURBO CLEAN LED FOLLOW SILENCE FP 6 11 ...

Page 3: ...ir requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants For more details please refer to the Information on servicing on INSTALLATION MANUAL This is only required for the unit adopts R32 R290 Refrigerant Caution Risk of fire flammable materials For R32 R290 units only 1 12 4 19 ...

Page 4: ...Ask an authorized dealer to install this air conditioner Inappropriate installation may cause water leakage electric shock or fire All repairs maintenance and relocation of this unit must be performed by an authorized service technician Inappropriate repairs can lead to serious injury or product failure WARNINGS FOR PRODUCT USE If an abnormal situation arises like a burning smell immediately turn ...

Page 5: ...ed together with burners or other heating devices thoroughly ventilate the room to avoid oxygen deficiency Turn off the air conditioner and unplug the unit if you are not going to use it for a long time Turn off and unplug the unit during storms Make sure that water condensation can drain unhindered from the unit Do not operate the air conditioner with wet hands This may cause electric shock Do no...

Page 6: ...his literature package Unit Parts Power Cable Some Units Remote Control Remote Control Holder Some Units Louver Front Panel Display window when defrost feature is activated when the unit is on when TIMER is set Display Code Meanings ON OFF TEMP TIMER ON TIMER OFF MODE FAN SLEEP SWING DIRECT TURBO CLEAN LED FOLLOW SILENCE FP Page 6 ...

Page 7: ......

Page 8: ...er using your mobile phone and a Wireless connection Louver Angle Memory some units When turning on your unit the louver will automatically resume its former angle Refrigerant Leakage Detection some units The indoor unit will automatically display EC when the unit detects refrigerant leakage NOTE ON ILLUSTRATIONS Illustrations in this manual are for explanatory purposes The actual shape of your in...

Page 9: ...LES When using COOL or DRY mode do not set louver at too vertical an angle for long periods of time This can cause water to condense on the louver blade which will drop on your floor or furnishings See Fig A When using COOL or HEAT mode setting the louver at too vertical an angle can reduce the performance of the unit due to restricted air flow Do not move louver by hand This will cause the louver...

Page 10: ...SLEEP button when you are ready to go to sleep When in COOL mode the unit will increase the temperature by 1 C 2 F after 1 hour and will increase an additional 1 C 2 F after another hour When in HEAT mode the unit will decrease the temperature by 1 C 2 F after 1 hour and will decrease an additional 1 C 2 F after another hour It will hold the new temperature for 5 hours then the unit will turn off ...

Page 11: ...or unit 2 Locate the MANUAL CONTROL button on the right hand side of the unit 3 Press the MANUAL CONTROL button one time to activate FORCED AUTO mode 4 Press the MANUAL CONTROL button again to activate FORCED COOLING mode 5 Press the MANUAL CONTROL button a third time to turn the unit off 6 Close the front panel Manual Operation Without Remote 2 CAUTION Manual Operation Without Remote Manual contr...

Page 12: ...f your unit and can also be bad for your health Make sure to clean the filter once every two weeks 6 Rinse the filter with fresh water then shake off excess water 7 Dry it in a cool dry place and refrain from exposing it to direct sunlight 8 When dry re clip the air freshening filter to the larger filter then slide it back into the indoor unit 9 Close the front panel of the indoor unit CAUTION Do ...

Page 13: ...eriod of time do the following Clean all filters Turn on FAN function until unit dries out completely Turn off the unit and disconnect the power Remove batteries from remote control Maintenance Pre Season Inspection After long periods of non use or before periods of frequent use do the following Check for damaged wires Clean all filters Check for leaks Replace batteries Make sure nothing is blocki...

Page 14: ...nit from overloading The unit cannot be restarted within three minutes of being turned off The unit may change its setting to prevent frost from forming on the unit Once the temperature increases the unit will start operating in the previously selected mode again The set temperature has been reached at which point the unit turns off the compressor The unit will continue operating when the temperat...

Page 15: ...s emitted from either the indoor or outdoor unit The unit may accumulate dust during extended periods of non use which will be emitted when the unit is turned on This can be mitigated by covering the unit during long periods of inactivity The unit emits a bad odor The unit may absorb odors from the environment such as furniture cooking cigarettes etc which will be emitted during operations The uni...

Page 16: ... is blocked Turn the unit off remove the obstruction and turn it back on Doors and windows are open Make sure that all doors and windows are closed while operating the unit Excessive heat is generated by sunlight Close windows and curtains during periods of high heat or bright sunshine Too many sources of heat in the room people computers electronics etc Reduce amount of heat sources Low refrigera...

Page 17: ...is too high or too low Install a manostat to regulate the voltage Poor heating performance The outdoor temperature is extremely low Use auxiliary heating device Cold air is entering through doors and windows Make sure that all doors and windows are closed during use Low refrigerant due to leak or long term use Check for leaks re seal if necessary and top off refrigerant Indicator lamps continue fl...

Page 18: ...IPM malfunction or IGBT over strong current protection High temperature protection of IPM module Inverter compressor drive error ...

Page 19: ...ns Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will take back the old appliance free of charge Sell the appliance to certified scrap metal dealers Special notice Disposing of this appliance in the forest or other natural surroundings endangers your hea...

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...ωστοποίηση Nl Belangrijke informatie in verband met het gebruikte koelmiddel Blaas geen R32 in de atmosfeer R32 is een gefluoreerd broeikasgas met een aardopwarmingsvermogen GWP van 675 Vul de volgende informatie in met onuitwisbare inkt op het label van het koelmiddel dat aangebracht werd op het toestel voor gebruik in openlucht 1 Fabrieksvulling 1 Zie waarderingslabel 2 Extra vulling 2 Bijkomend...

Page 25: ...tā slodze 1 Skatiet datu uzlīmi 2 Papilduzlāde 2 Papildu uzpildīšanas apjoms ja uzstādīts 3 Kopējā slodze 1 2 4 Tonnas CO2 Ekvivalenta kopējā slodze GWP 1000 5 Dzesējošās vielas veids skatiet datu uzlīmi 6 GWP 675 A Āra ierīce B Dzesējošās vielas cilindrs C Paziņojums Et Oluline teave külmutusagensi kasutamise kohta Ärge ventileerige külmutusagensit R32 atmosfääri R32 on fluoritud kasvuhoonegaas m...

Page 26: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details CS441 AF23 ...

Reviews: