background image

En-3

Fig. 6 Remote Control Unit

J

SLEEP button

K

MASTER CONTROL button

L

SET TEMP. button ( 

 

/

 

 

)

M

Signal Transmitter

N

TIMER MODE button

O

TIMER SET ( 

 / 

 ) button

P

FAN CONTROL button

Q

START/STOP button

R

SET button (Vertical)

S

SET button (Horizontal)

T

SWING button

U

RESET button

V

TEST RUN button

This button is used when installing the
conditioner, and should not be used un-
der normal conditions, as it will cause the
air conditioner’s thermostat function to op-
erate incorrectly.

If this button is pressed during normal op-
eration, the unit will switch to test opera-
tion mode, and the Indoor Unit’s OPERA-
TION Indicator Lamp and TIMER Indicator
Lamp will begin to flash simultaneously.

To stop the test operation mode, press the
START/STOP button to stop the air condi-
tioner.

W

CLOCK ADJUST button

X

Remote Control Unit Display (Fig. 7)

Y

Transmit Indicator

Z

Clock Display

[

Operating Mode Display

\

Timer Mode Display

]

Fan Speed Display

`

Temperature SET Display

a

SLEEP Display

b

SWING Display

NAME OF PARTS

  Refer to the folded out page on the cover.

Fig. 1 Indoor Unit

1

Operating Control Panel (Fig. 2)

2

MANUAL AUTO button

When kept on pressing the MANUAL
AUTO button for more than 10 seconds,
the forced cooling operation will start.

The forced cooling operation is used at the
time of installation.
Only for authorized service personnel's
use.

When the forced cooling operation starts
by any chance, press the START/STOP but-

ton to stop the operation.

3

Indicator (Fig. 3)

4

Remote Control Signal Receiver

5

OPERATION Indicator Lamp (red)

6

TIMER Indicator Lamp (green)

If the TIMER indicator lamp flashes when
the timer is operating, it indicates that a
fault has occurred with the timer setting

(See Page 14 Auto Restart).

7

SUPER QUIET Indicator Lamp (orange)

8

Intake Grille (Fig. 4)

9

Front Panel

0

Air Filter

A

Air Flow Direction Louver

B

Power Diffuser

C

Right-Left Louver

(behind Air Flow Direction Louver)

D

Drain Hose

E

Air Cleaning Filter

Fig. 5 Outdoor Unit

F

Intake Port

G

Outlet Port

H

Pipe Unit

I

Drain port (bottom)

Summary of Contents for Inverter Halcyon AOU24CL

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ...ORBÉE 2 31 kW NSITÉ 10 1 A CIFICATIONS SUPPLY 208 230 V 60 Hz G ACITY 24 200 BTU h T POWER 2 31 kW RENT 10 1 A INDOOR UNIT UNIDAD INTERIOR UNITÉ INTÉRIEURE OUTDOOR UNIT UNIDAD EXTERIOR UNITÉ EXTÉRIEURE ASU24CL AOU24CL COOLING MODEL MODÈLE REFROIDISSANT MODELO DE REFRIGERACIÓN COOLING MODEL MODÈLE REFROIDISSANT MODELO DE REFRIGERACIÓN ECIFICACIONES TACIÓN 208 230 V 60 Hz RACIÓN ACIDAD 33 100 BTU h ...

Page 5: ...ssi ble through dual use of both an UP DOWN air direction swing and RIGHT LEFT air direction swing Since UP DOWN air direction flaps operate automatically according to the oper ating mode of the unit it is possible to set air direction based on the operating mode REMOVABLE OPEN PANEL The indoor unit s Open Panel can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILT...

Page 6: ...isplay Fan Speed Display Temperature SET Display a SLEEP Display b SWING Display NAME OF PARTS Refer to the folded out page on the cover Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authoriz...

Page 7: ...e direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 W Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 6 O to adjust the clock to the current time button Press to advance the time bu...

Page 8: ...d a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 P Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Cooling As the room temperature approaches that of the thermostat setting the fan speed b...

Page 9: ...ation Cooling to adjust the temperature to the value set in the thermostat The monitor operation range is 4 F relative to the thermostat set ting If the mode automatically selected by the unit is not what you wish select one of the mode operation COOL DRY FAN About Mode Operation Cooling Use to cool your room Dry Use for gently cooling while dehumidifying your room You cannot heat the room during ...

Page 10: ...econds later the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operat...

Page 11: ...ling during sleep the SLEEP timer function automatically modifies the thermostat setting in accord ance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 2 F every sixty minutes When the thermo stat has been raised a total of 4 F the thermostat setting...

Page 12: ...be automatically returned to the 3 range When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 6 R Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air flow Direction Setting 1 ...

Page 13: ...ording to the current airflow direc tion Airflow direction is 1 4 for cooling dry With the upper airflow direction louver in the horizontal position the lower airflow direction louver moves swings to direct airflow to a wide area Left right swing The airflow direction louvers move swing in the left right airflow direction Up down left right swing The airflow direction louvers move swing in both th...

Page 14: ...ille 1 Align the sides of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and ...

Page 15: ...disposable filters They can not be washed and reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every three months Please buy delicated air cleaning filters UTR FA13 1 Sold separately to exchange the use...

Page 16: ...mitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensation and misting The fan may operate at very low speed during Dr...

Page 17: ...perly OPERATING TIPS If the problem persists after performing these checks or if you notice burning smells or both the ORERATION Indicator Lamp Fig 3 5 and the TIMER Indicator Lamp Fig 3 6 flashes or only the TIMER Indicator Lamp Fig 3 6 flashes immediately stop operation disconnect the Power Supply and consult authorized service personnel AUTO Restart In Event of Power Interruption The air condit...

Page 18: ...f lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip onto the floor or other o...

Page 19: ......

Reviews: