- (02 - 01) -
OUTDOOR UNIT
AOU9-12RLS
OUTDOOR UNIT
AOU9-12RLS
2-1. SPECIFICATIONS
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 80°F (26.67°C)DB / 67°F (19.44°C)WB, and outdoor temperature of 95°F (35°C) DB/75°F (23.9°C)WB.
Heating : Indoor temperature of 70°F (21.11°C)DB / 59°F (15°C)WB, and outdoor temperature of 47°F (8.33°C) DB/43°F (6.11°C)WB.
Pipe length : 24ft.7in.(7.5 m), Height difference : 0 m.(Outdoor unit - Indoor unit)
The protective function might work when using it outside the temperature range mentioned above.
AOU9RLS
AOU12RLS
Power source
Available voltage range
A
6.2
6.2
Cooling
1106 (1880)
1201 (2040)
Heating
1059 (1800)
1059 (1800)
Type × Q'ty
Motor output
W
115
115
Cooling
48
49
Heating
48
50
Dimensions (H × W × D)
in.(mm)
Fin pitch
FPI
20
20
Rows x Stages
2×28
2×28
Pipe type
Fin type
Motor output
W
850
850
Charge
Material
Color
mm
inch
mm
inch
Net
Gross
Liquid
Gas
Method
Max. length
Pre-charge length
Max. height difference
Cooling
Heating
5 to 75 (-15 to 24)
Φ1/4 (Φ6.35)
Φ3/8 (Φ9.52)
66 (20)
49 (15)
49 (15)
14 to115 (-10 to 46)
Flare
Steel
BEIGE
(Approximate color of MUNSELL 10YR 7.5/1.0 )
Rotary x 1
R410A
POE
712 × 935 × 400
28-1/32 × 36-13/16 × 15-3/4
620×790×298
24-13/32 × 31-3/32 × 11-23/32
INVERTER HEAT PUMP
208/230V ~ 60Hz
187-253V ~ 60Hz
Propeller fan × 1
ft.
(m)
Connection pipe
Size
in.
(mm)
Starting current
Compressor
Type × Q'ty
Refrigerant
Type
Sound pressure level
lb.oz.(g)
Refrigerant oil
Type
Enclosure
Heat exchanger type
lb.(kg)
Dimensions
( H×W×D)
Net
Gross
°F
(°C)
Operation range
Type
Model name
Fan
Airflow
rate
CFM
(m
3
/h)
dB(A)
Weight
34-11/16 x 23-5/32 x 1-7/16 (881×588×36.4)
2lb. 9oz.(1150)
82 (37)
93 (42)
Copper
Aluminium