background image

En-13

PROGRAM TIMER OPERATION

1

  Press the TIMER SETTING button 

 

.

 

At the beginning, “

” will be  ashing, so press 

the SELECT button 

 to select “

” within 

”.

 

Press the NEXT button 

 

.

2

  Press the SELECT button 

 to set the desired ON time

.

 

Press the NEXT button 

 

.

3

  Press the SELECT button 

 to set the desired OFF time

.

4

  Press the SEND button 

 

.

In the case of the ON timer, the air conditioner will stop running.

1

  Press the ON/OFF button 

 while “

” is 

displayed.

2

  

” will disappear from the display.

To Stop Air Conditioner Operation 
while the Timer is Operating

Press the START/STOP button 

.

● 

The program timer allows you to integrate OFF timer and ON timer operations in a 

single sequence. The sequence can involve 1 transition from OFF timer to ON timer, 
or from ON timer to OFF timer, within a 24 hour period.

● 

Before using the timer function, be sure that the Remote Controller is set to the cor-
rect current time.

  Press the ON/OFF button 

 while “

” is not displayed to set the ON (OFF) TIMER again for the time you set last time.

  Only run operation once with the OFF TIMER and ON TIMER combined.

(Either OFF  ON or ON  OFF once)

  Out of OFF TIMER and ON TIMER, the timer which has the nearest set time to the present will run  rst. You can display the 

sequence of operation by using the arrows on the display part of the remote control (“

” or “

”). 

  You cannot combine WEEKLY TIMER, ON/OFF TIMER (PROGRAM TIMER), and SLEEP TIMER

.

  The PROGRAM TIMER cannot be set for times more than 24 hours in advance.

Flashing the “

”.

To cancel the PROGRAM timer

To use the PROGRAM Timer

If you want to cancel the setting midway, please press the TIMER 

SETTING button 

 instead of pressing the SEND button 

.

9319356068_OM_En.indd   13

4/27/2012   1:16:02 PM

Summary of Contents for Inverter 9319356068

Page 1: ...RIGERANT This Air Conditioner contains and operates with refrigerant R410A THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this product 9319356068_OM_En indd 1 4 27 2012 1 15 38 PM ...

Page 2: ...der indoor unit or out door unit Dripping condensation from the unit might get them wet and may cause damage or malfunction of your property Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power supply when not using the indoor unit for extended periods Check the condition of the installation stand for dam...

Page 3: ...R UNIT LOW NOISE OPERATION WEEKLY TIMER ON OFF TIMER PROGRAM TIMER SLEEP TIMER POWERFUL OPERATION Energy saving and Comfortable function INVERTER At the start of operation large amount of power is used to bring the room quickly to the desired temperature Afterward the air conditioner automatically switches to a low power set ting for economic and comfortable operation HUMAN SENSOR ENERGY SAVING Wh...

Page 4: ...PERATION is operating INDOOR UNIT Drain Hose Air Cleaning Filter Open the Intake Grille See page 20 Air Filter Air ow Direction Louver Remote controller Batteries Air cleaning lters Remote controller holder Tapping screws M3 12 mm Accessories of the indoor unit Human Sensor Open Panel Right Left Louver behind Air ow Direction Louver It opens at the same time of operation and shuts when operation s...

Page 5: ... Display SWING Display FAN Speed Display To facilitate explanation the accompanying illustration has been drawn to show all possible indicators in actual opera tion however the display will only show those indicators appropriate to the current operation After the button is pressed on remote control only the operated part is displayed until the transmission of the signal is completed It is a conven...

Page 6: ...e increments hold the buttons depressed to change the time quickly in 10 minute increments 4 Press the SEND button This completes the time setting and starts the clock Press the SEND button when you are close to the main unit If you do so when far from the main unit the signal may not get properly sent and the settings may not get properly con gured To Use the Remote Controller The Remote Controll...

Page 7: ...isplay will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the temperature setting the fan speed becomes slower When the room temperature is close to the set temperature the inner room fan may oc...

Page 8: ... on the outdoor unit and its performance may be reduced In order to remove such frost the air conditioner will automatically enter the defrost cycle from time to time During Automatic Defrosting operation the OPERATION Indicator Lamp will ash and the Heat operation will be interrupted After the start of Heating operation it takes some time before the room gets warmer Cooling Use to cool your room ...

Page 9: ... button to adjust the vertical air ow louvers Attempting to move them man ually could result in improper operation in this case stop operation and restart The louvers should begin to operate properly again During use of the Cooling and Dry modes do not set the Airflow Direc tion Louvers in the Heating range 4 7 for many hours since water vapor may condense near the outlet louvers and drops of wate...

Page 10: ...ture is very different from the temperature de ned in temperature setting such as when immediately after starting the operation If ENERGY SAVING is set If ENERGY SAVING is off HUMAN SENSOR ENERGY SAVING Since the human sensor detects infrared light given out by people there may be cases where this detection is incorrect Situations in which the sensor will detect no people in the room even when the...

Page 11: ...ant to quickly cool down or warm up the room Begin Air Conditioner operation before performing this procedure To use POWERFUL Operation Press the POWERFUL button Only as for this button operation the beep sound is different from the others Powerful operation start Beep 3 times Pi Pi Pi Others Beep 2 times Pi Pi To stop POWERFUL Operation Press the POWERFUL button again Normal operation begins Abou...

Page 12: ... the OUTDOOR UNIT LOW NOISE Operation Press the OUTDOOR UNIT LOW NOISE button LOW NOISE appears on the Remote Controller display To stop the OUTDOOR UNIT LOW NOISE Operation Press the OUTDOOR UNIT LOW NOISE button LOW NOISE disappears from the Remote Controller display Normal operation begins OUTDOOR UNIT LOW NOISE OPERATION OUTDOOR UNIT LOW NOISE Operation mode reduces the noise level of the outd...

Page 13: ... The air conditioner will stop at the time you set Before using the timer function be sure that the Remote Controller is set to the cor rect current time Press the ON OFF button while is not displayed to set the ON OFF TIMER again for the time you set last time You cannot combine WEEKLY TIMER ON OFF TIMER PROGRAM TIMER and SLEEP TIMER or will be ashing To cancel the ON timer or OFF timer To use th...

Page 14: ...imer to OFF timer within a 24 hour period Before using the timer function be sure that the Remote Controller is set to the cor rect current time Press the ON OFF button while is not displayed to set the ON OFF TIMER again for the time you set last time Only run operation once with the OFF TIMER and ON TIMER combined Either OFF ON or ON OFF once Out of OFF TIMER and ON TIMER the timer which has the...

Page 15: ...utes Set time Set time 1 hour 1 C 2 C 1 Press the TIMER SETTING button will be rstly displayed ashing Press the SELECT button to select Press the NEXT button 2 Press the SELECT button to set the OFF time button 0 5H 1H 2H 3H 5H 7H 9H button 0 5H 7H 5H 3H 2H 1H 9H 3 Press the SEND button You can set the OFF TIMER to any time you want when you go to sleep The product adjusts the temperature to make ...

Page 16: ...the ON OFF together with the SLEEP timer If you want to run the product on WEEKLY TIMER after the time is up after using the ON OFF Timer Program Timer or SLEEP Timer within the WEEKLY TIMER you need to set the WEEKLY TIMER again See page 19 Using in these cases of WEEKLY timer Example of how to set the timer 2 You can specify a given temperature in the ON setting in WEEKLY TIMER You can set the t...

Page 17: ...select operation with the ON Timer OFF Timer or without a timer To operate without a timer 1 Press the NEXT button to go back to step 2 and con g ure the next setting 2 Press the SEND button to nish Press the NEXT button WEEKLY TIMER OPERATION Flashing the The program and day of the week will be ashing Flashing the or Program 1Week Program Monday Program Tuesday Program Sunday Program 1Week Progra...

Page 18: ...time display will be ashing The temperature display will be ashing If you want to cancel the setting midway please press the TIMER SETTING button instead of pressing the SEND button 4 Press the SELECT button to set the desired ON time or OFF time If you selected OFF in step 3 1 Press the NEXT button to go back to step 2 and con gure the next setting 2 Press the SEND button Press the NEXT button 5 ...

Page 19: ...KLY TIMER ON OFF TIMER PROGRAM TIMER and SLEEP TIMER WEEKLY TIMER OPERATION 1 Press the TIMER SETTING button Firstly since will be ashing Press the NEXT button 2 Check the program the day and the time with the SELECT button 3 Press the TIMER SETTING button to return to the regular screen To cancel the WEEKLY timer Check the schedule 9319356068_OM_En indd 18 4 27 2012 1 16 10 PM ...

Page 20: ... During periods of normal use the Air Filters should be cleaned every 2 weeks 3 Replace the air lters Align the sides of the air lter with the panel and push in fully making sure the 2 lower tabs are returned properly to their holes in the panel Air lter tabs 2 places Close the Intake Grille 1 Release the grille stay Grille stay 2 Close the intake grille Tab of 3 places Tab If the intake grille is...

Page 21: ...kage Generally the lters should be exchanged about every 3 months Please buy dedicated air cleaning filters UTR FA16 Sold separately to exchange the used dirty air cleaning lter NEGATIVE AIR IONS DEODORIZING FILTER light blue 1 sheet The lter should be exchanged about every 3 years so as to maintain the deodorizing effect Filter frame is not a one off product Please buy dedicated deodorizing lter ...

Page 22: ...ing or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the cool air emitted from the indoor unit resulting in con densation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation 23 Air ow is weak or stops When Heating operati...

Page 23: ...rformance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recir culating air throughout the room with the result that some time may be required after rst starting the air conditioner until the room is heated Microcomputer controlled Automatic Defrosting When using the Heating mode ...

Page 24: ...ction with other auxiliary space heaters as required Seasonal and outdoor temperature conditions the struc ture of the rooms and the number of persons present may also result in differences of operating ef ciency We rec ommend that you try various operating patterns in order to con rm the level of heating and cooling output provided by your units and use the units in the way that best matches your...