Fujitsu Halcyon AOU36CX Operating Manual Download Page 16

En-15

Operation and Performance

TROUBLESHOOTING

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

Symptom

Doesn’t operate at all:

Poor Cooling
(or *Heating)
performance:

The unit operates
differently from the
remote control unit’s
setting:

Signal is not received after
replacing the batteries for
the remote control unit:

See Page

8 to 9

5

13

CHECK ONCE

MORE

Items to check

Has there been a power failure?

Has a fuse blown out, or a circuit breaker been tripped?

Is the timer operating?

Is the air filter dirty?

Are the air conditioner’s intake filter or outlet port blocked?

Did you adjust the room temperature settings (thermostat) cor-
rectly?

Is there a window or door open?

In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)

In the case of Cooling operation, are there heating apparatus and
computers inside the room, or are there too many people in the
room?

Are the remote control unit’s batteries dead?

Are the remote control unit’s batteries loaded properly?

Are you using an air conditioner signal code other than signal
code A?

If the problem persists after performing these checks, or if you notice burning smells, or the TIMER indicator lamp (Fig. 3 

6

)

flashes, immediately stop operation, disconnect the power supply, and consult authorized service personnel.

OPERATING TIPS

*Heating Performance

This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that heat
indoors. As a result, the operating performance is reduced
as outdoor air temperature drops. If you feel that insuffi-
cient heating performance is being produced, we recom-
mend you use this air conditioner in conjunction with
another kind of heating appliance.

Heat-pump air conditioners heat your entire room by
recirculating air throughout the room, with the result that
some time may be required after first starting the air con-
ditioner until the room is heated.

*Microcomputer-controlled Automatic Defrosting

When using the Heating mode under conditions of low out-
door air temperature high humidity, frost may form on the
outdoor unit, resulting in reduced operating performance.

In order to prevent this kind of reduced performance, this
unit is equipped with a Microcomputer-controlled Automatic
Defrosting function. If frost forms, the air conditioner will
temporarily stop, and the defrosting circuit will operate
briefly (for about 7 to 15 minutes).

During Automatic Defrosting operation, the OPERATION
indicator lamp (red) will flash.

*When Indoor and Outdoor Temperatures are High

When both indoor and outdoor temperatures are high dur-
ing use of the heating mode, the outdoor unit’s fan may stop
at times.

*Low Ambient Cooling

When the outdoor temperature drops, the outdoor unit’s fans
may switch to Low Speed.

Summary of Contents for Halcyon AOU36CX

Page 1: ...WALL MOUNTED TYPE KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO P N9373597018 02 Indoor Unit AWU36CX Outdoor Unit AOU36CX English Français Español ...

Page 2: ...upply cord Turn off power source when not using the unit for extended periods Always turn off the electrical breaker or disconnect the power supply plug whenever cleaning the air conditioner or the air filter Connection valves become hot during Heating handle with care Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow Do not ...

Page 3: ...lowered during the period of operation during Cool ing or Dry mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation OMNI DIRECTIONAL AIR FLOW SWING OPERATION Three dimensional control over air dir...

Page 4: ...En 3 Fig 2 Fig 3 Fig 4 Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle NAME OF PARTS Fig 5 Fig 6 Fig 1 Fig 8 Fig 7 0 1 4 9 A B 3 7 6 5 8 2 C D D E ...

Page 5: ...RT STOP button M AIR FLOW DIRECTION VERTICAL SET button N AIR FLOW DIRECTION VERTICAL SWING button O AIR FLOW DIRECTION HORIZONTAL SET button P AIR FLOW DIRECTION HORIZONTAL SWING button Q TIME ADJUST button R ACL button Rear side Fig 7 S TEST RUN Touch the two metal contacts with a me tallic object to send the signal to perform a test run Perform a test run only when installing the air conditione...

Page 6: ...it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Fig 6 Q Use the tip of a ball point pen or other small object to press the button 2 Use the SET TIME buttons Fig 6 H to adjust the clock to the current time button Press to advance...

Page 7: ...nds later the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 K Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW About three seconds later the entire display will reappear When set to AUTO Heating Fa...

Page 8: ... very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan set ting This period of time is provided to allow the indoor unit to warm up before beginning full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time...

Page 9: ...ner Operation while the Timer is Operating Press the START STOP button To Change Operating Conditions If you wish to change the operating conditions Mode Fan Speed Thermostat Setting after making the timer setting wait until the entire display reappears then press the appropriate buttons to change the operating condition desired To Cancel the Timer Use the TIMER button to select TIMER RESET The ai...

Page 10: ...timer setting During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 2 F every sixty minutes When the thermo stat has been raised a total of 4 F the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting 4 F 6 F 8 F 30 minutes 2 F 1 hour 1 hour 30 mi...

Page 11: ...ith infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Example When set to vertical air direc tion Example When set to horizontal air di rection Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION VERTICAL SET button Fig 6 M Each time the button is pressed the air direction range will change as follows 1 2...

Page 12: ...s in the range 4 to 5 for long periods of time since water vapor may condense near the outlet port and drops of water may drip from the air conditioner To select Horizontal airflow SWING Operation Press the AIR FLOW DIRECTION HORIZONTAL SWING button Fig 6 P The SWING indicator lamp HORIZONTAL SWING Fig 3 8 will light In this mode the RIGHT LEFT air direction louvers will swing automatically to dir...

Page 13: ...o accumulate on the intake filters air flow will be reduced lowering operating efficiency and increasing noise During periods of normal use the intake filters should be cleaned every five weeks 3 Install the intake filters Hang the edge of the intake filter on the body Using this as a support point push forward to secure as shown in the illustration When using the optional Air Cleaning Filter Inst...

Page 14: ...ss the MASTER CONTROL button Fig 6 G for at least five seconds to display the current signal code initially set to 3 Press the buttons Fig 6 H to change the signal code between Match the code on the dis play to the air conditioner signal code 4 Press the MASTER CONTROL button again to return to the clock display The signal code will be changed If no buttons are pressed within 30 seconds after the ...

Page 15: ... of minute expansion and contraction of the front cover due to temperature changes During Heating operation a sizzling sound may be heard occa sionally This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operatio...

Page 16: ...d consult authorized service personnel OPERATING TIPS Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we recom mend you use this air conditioner in conju...

Page 17: ... Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle Temperature and Humidity Range COOLING DRY MODE COOLING MODELS If the air conditioner is operated under higher temperature conditions than those listed the built in protection circuit may operate to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower te...