ADJUSTING THE DIRECTION OF AIR CIRCULATION

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

Vertical (up-down) direction of airflow is adjusted by pressing the remote control unit’s AIR FLOW DIRECTION VERTICAL SET
button. Horizontal (right-left) direction of airflow is adjusted by pressing the remote control unit’s AIR FLOW DIRECTION
HORIZONTAL SET button.

 DANGER!

Never place fingers or foreign objects inside

the outlet ports, since the internal fan oper-
ates at high speed and could cause personal
injury.

Always use the remote control unit’s

AIR FLOW DIRECTION button to adjust
the UP/DOWN air direction flaps or
RIGHT/LEFT air direction louvers. At-
tempting to move them manually

could result in improper operation; in
this case, stop operation and restart.
The louvers should begin to operate

properly again.

During use of the Cooling and Dry

modes, do not set the UP/DOWN air
direction flaps in the range 

4

 to 

5

 for

long periods of time, since water vapor

may condense near the outlet port and
drops of water may drip from the air
conditioner.

When used in a room with infants, chil-
dren, elderly or sick persons, the air

direction and room temperature
should be considered carefully when
making settings.

Example:

When set to vertical air direc-
tion

Example:

When set to horizontal air di-
rection

Vertical Air Direction Adjustment

Press the AIR FLOW DIRECTION VERTICAL SET button (Fig. 6 

M

).

Each time the button is pressed, the air direction range will change as follows:

1

 

 

2

 

 

3

 

 

4

 

 

5

Types of Air flow Direction Setting:

1

,

2

,

3

:

During Cooling/Dry mode

1

,

2

,

3

,

4

,

5

: * During Heating mode

The remote control unit’s display does
not change.

Fig. 9

Use the air direction adjustments within the ranges shown above.

The vertical airflow direction is set automatically as shown, in accordance with
the type of operation selected.

During Cooling/Dry mode : Horizontal flow 

1

* During Heating mode

: Downward flow 

5

During AUTO mode operation, for the first minute after beginning operation,
airflow will be horizontal 

1

; the air direction cannot be adjusted during this pe-

riod.

Horizontal Air Direction Adjustment

Press the AIR FLOW DIRECTION HORIZONTAL SET button (Fig. 6 

O

).

Each time the button is pressed, the air direction range will change as follows:

1

 

 

2

 

 

3

 

 

4

 

 

5

The remote control unit’s display does
not change.

Use the air direction adjustments within the ranges shown above.

Fig. 10

RIGHT/LEFT air direction louvers

1

2

3

4

5

Summary of Contents for Halcyon AOU36CX

Page 1: ...WALL MOUNTED TYPE KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO P N9373597018 02 Indoor Unit AWU36CX Outdoor Unit AOU36CX English Français Español ...

Page 2: ...upply cord Turn off power source when not using the unit for extended periods Always turn off the electrical breaker or disconnect the power supply plug whenever cleaning the air conditioner or the air filter Connection valves become hot during Heating handle with care Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow Do not ...

Page 3: ...lowered during the period of operation during Cool ing or Dry mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation OMNI DIRECTIONAL AIR FLOW SWING OPERATION Three dimensional control over air dir...

Page 4: ...En 3 Fig 2 Fig 3 Fig 4 Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle NAME OF PARTS Fig 5 Fig 6 Fig 1 Fig 8 Fig 7 0 1 4 9 A B 3 7 6 5 8 2 C D D E ...

Page 5: ...RT STOP button M AIR FLOW DIRECTION VERTICAL SET button N AIR FLOW DIRECTION VERTICAL SWING button O AIR FLOW DIRECTION HORIZONTAL SET button P AIR FLOW DIRECTION HORIZONTAL SWING button Q TIME ADJUST button R ACL button Rear side Fig 7 S TEST RUN Touch the two metal contacts with a me tallic object to send the signal to perform a test run Perform a test run only when installing the air conditione...

Page 6: ...it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Fig 6 Q Use the tip of a ball point pen or other small object to press the button 2 Use the SET TIME buttons Fig 6 H to adjust the clock to the current time button Press to advance...

Page 7: ...nds later the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 K Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW About three seconds later the entire display will reappear When set to AUTO Heating Fa...

Page 8: ... very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan set ting This period of time is provided to allow the indoor unit to warm up before beginning full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time...

Page 9: ...ner Operation while the Timer is Operating Press the START STOP button To Change Operating Conditions If you wish to change the operating conditions Mode Fan Speed Thermostat Setting after making the timer setting wait until the entire display reappears then press the appropriate buttons to change the operating condition desired To Cancel the Timer Use the TIMER button to select TIMER RESET The ai...

Page 10: ...timer setting During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 2 F every sixty minutes When the thermo stat has been raised a total of 4 F the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting 4 F 6 F 8 F 30 minutes 2 F 1 hour 1 hour 30 mi...

Page 11: ...ith infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Example When set to vertical air direc tion Example When set to horizontal air di rection Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION VERTICAL SET button Fig 6 M Each time the button is pressed the air direction range will change as follows 1 2...

Page 12: ...s in the range 4 to 5 for long periods of time since water vapor may condense near the outlet port and drops of water may drip from the air conditioner To select Horizontal airflow SWING Operation Press the AIR FLOW DIRECTION HORIZONTAL SWING button Fig 6 P The SWING indicator lamp HORIZONTAL SWING Fig 3 8 will light In this mode the RIGHT LEFT air direction louvers will swing automatically to dir...

Page 13: ...o accumulate on the intake filters air flow will be reduced lowering operating efficiency and increasing noise During periods of normal use the intake filters should be cleaned every five weeks 3 Install the intake filters Hang the edge of the intake filter on the body Using this as a support point push forward to secure as shown in the illustration When using the optional Air Cleaning Filter Inst...

Page 14: ...ss the MASTER CONTROL button Fig 6 G for at least five seconds to display the current signal code initially set to 3 Press the buttons Fig 6 H to change the signal code between Match the code on the dis play to the air conditioner signal code 4 Press the MASTER CONTROL button again to return to the clock display The signal code will be changed If no buttons are pressed within 30 seconds after the ...

Page 15: ... of minute expansion and contraction of the front cover due to temperature changes During Heating operation a sizzling sound may be heard occa sionally This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operatio...

Page 16: ...d consult authorized service personnel OPERATING TIPS Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we recom mend you use this air conditioner in conju...

Page 17: ... Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle Temperature and Humidity Range COOLING DRY MODE COOLING MODELS If the air conditioner is operated under higher temperature conditions than those listed the built in protection circuit may operate to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower te...

Reviews: