1.1 Key Features
High-speed I/O interface
One built-in 40 MB/s UltraSCSI Single-Ended interface for internal devices.
One built-in 100BASE-TX interface (10/100 Mbps, auto-sensing).
The GP7000F has some 64-bits PCI (Peripheral Component Interconnect) buses.
Additional interfaces, such as 100BASE-TX, FDDI, ATM, can be provided by installing PCI
cards. Both short and long size PCI cards can be installed. (*1)
*1)
The maximum length of the cards that can be installed in PCI slots
#
8 to
#
12 of the
M600R Main cabinet is 19.4cm.
High-performance, Large-capacity File Devices
Up to 22, 7200rpm or 10000rpm, UltraSCSI disk drives can be built in. Note that the number of
drives that can be installed depends on each model.
The disk drives can be hot-swappable
One CD-ROM drive unit is provided as standard.
One tape drive can be built in as optional.
Reliability, Availability, and Serviceability (RAS) features
Error Correction Code (ECC) is implemented for on-chip cache, external cache, memory
module and data paths. The data for the I/O data path(PCI) is protected by parity.
Table 1.1 Data Protection for Components and Interfaces
Components and interfaces
Processor (on-chip & external cache)
Memory
Data path
Address path
I/O bus (PCI)
Processor operation
Built-in basic SCSI, LAN, parallel
Data protection method
By ECC (corrects 1 bit and detects 2 bit)
By ECC (corrects 1 bit and detects 2 bit)
By ECC (corrects 1 bit and detects 2 bit)
By parity
By parity
Operation monitoring by an independent
processor
By parity, IP check sum
Note:
The RS232C interface and a floppy disk on a standard configuration are not
protected by parity.
Power-on diagnostics are executed on the system components, such as processors, memory
modules and so on, during initial power-on or reset of the system.
Automatic System Reconfiguration (ASR) isolates faulty hardware components immediately
after detecting it. The ASR function isolates not only faulty components detected during initial
power-on but also those detected while the system is running. However, the ASR function
cannot restart the system if errors are detected in the resources required for booting up the
system, or in the basic components of the system.
3
Summary of Contents for GP 7000F
Page 1: ...Edition December 1999 GP 7000F M200 M200R M400A M400R M600 M600R ...
Page 4: ......
Page 11: ...P321 E102 02EN USER S MANUAL ...
Page 12: ......
Page 19: ...vii ...
Page 22: ......
Page 27: ...CONTENTS 14 4 SCF Error Messages 160 v ...
Page 28: ......
Page 60: ......
Page 74: ......
Page 100: ......
Page 114: ......
Page 178: ......
Page 190: ......
Page 199: ......