CHAPTER 9 Expansion File Unit Type-2 (GP7B7FLxx)
Installation specifications
Table 9.4
Installation Specifications of Expansion File Unit Type-2
Item
Specification
Mass
Up to 30kg (approx.70 lb)
Power condition
Input voltage
Single phase
100 to 120 VAC
(+-10%)
Single phase
200 to 240 VAC
(+-10%)
Input frequency
50/60 Hz (+2 to -4%)
Maximum consumption current
3.0 A
Leakage current (1 for each cable)
1.2 mA or less
1.5 A
2.7 mA or less
Ground resistance
100ohm or less ( class C installation standard)
Temperature condition Operating
5 to 35 degrees Celsius (+41 to +95 F) (*1)
Not operating
0 to 50 degrees Celsius (+32 to +122F)
Humidity condition
Operating
20 to 80%RH (no condensation)
Not operating
8 to 80% RH (no condensation)
Vibrations condition
Operating
0.2 G
Idle
0.4 G
Noise
50 db (A) (*2)
Installation
Rack mount type (3 pitches)
*1:
If the ambient temperature exceeds 35 degrees Celsius (+95F) during operation, a
warning message is displayed. Take steps to rectify the problem immediately.
*2:
The indicated noise is the mean value of the measurements obtained in an anechoic
chamber with less echoic influence. The actual noise measured at the installation site
may be greater than the indication noise due to surrounding noise and echoes.
112
Summary of Contents for GP 7000F
Page 1: ...Edition December 1999 GP 7000F M200 M200R M400A M400R M600 M600R ...
Page 4: ......
Page 11: ...P321 E102 02EN USER S MANUAL ...
Page 12: ......
Page 19: ...vii ...
Page 22: ......
Page 27: ...CONTENTS 14 4 SCF Error Messages 160 v ...
Page 28: ......
Page 60: ......
Page 74: ......
Page 100: ......
Page 114: ......
Page 178: ......
Page 190: ......
Page 199: ......