![Fujitsu General AOHG09KMCDN Design & Technical Manual Download Page 59](http://html.mh-extra.com/html/fujitsu/general-aohg09kmcdn/general-aohg09kmcdn_design-and-technical-manual_2343863059.webp)
7. Additional charge calculation
7-1. Model: AOHG09KMCDN
Refrigerant type
R32
Refrigerant amount
g
850
Refrigerant charge
Total pipe length
m
15 or less
20 (Max.)
20 g/m
Additional charge
g
0
100
7-2. Model: AOHG12KMCDN
Refrigerant type
R32
Refrigerant amount
g
940
Refrigerant charge
Total pipe length
m
15 or less
20 (Max.)
20 g/m
Additional charge
g
0
100
7-3. Model: AOHG14KMCDN
Refrigerant type
R32
Refrigerant amount
g
1,120
Refrigerant charge
Total pipe length
m
15 or less
20 (Max.)
20 g/m
Additional charge
g
0
100