3.61: RMVD
Issue 9, May 1999
FNC and FNC Customer Use Only
Vol. ll, Page 480.3-37
Maintenance and Trouble Clearing
FJTU-320-515-480
3.61
RMVD
3.62
SVM
Table 3-59: RMVD (Plug-In Unit Removed)—Alarm Event
AID
Type
Direction
Probable Cause
Suggested Corrective Action
EQPT
NA
The plug-in unit is not
properly seated, or it
is removed.
• Reseat the unit or replace it.
• If a plug-in unit is not required in the slot generating
the alarm, the alarm can be cleared by deleting the
equipment (slot).
Table 3-60: SVM (Software Version Mismatch)—Standing Condition
AID
Type
Direction
Probable Cause
Suggested Corrective Action
EQPT
NA
NE is equipped with a combination
of different software files or the
software files are unreadable.
Examples:
• One or more file versions do not
match the ones listed in the
configuration file.
• Software versions in one or
more CPU(s) are unreadable.
Plug-in units that contain mismatched or
unreadable software files display a flashing
red FAIL LED when SVM occurs. The NE
generates an alarm to the office alarm
interfaces, OS/DCC, and craft interfaces.
Correct for the SVM condition is available in
the following retrieve commands:
• CPU in SVM condition—RTRV-ALM-
ALL-RTRV-COND-ALL
• Expected file version—READ-CONFIG
• Observed file version—RTRV-FILE-NVM
Refer to FJTU-320-515-270, Section 7,
Reports, for evaluating compatibility in terms
of SVM and system release numbers for
software download systems.
When the SVM condition is corrected, the NE
deactivates the flashing red LED and office
alarms and generates a clear message to the
OS/DCC/craft interfaces.