3.8: B1ERR
Issue 9, May 1999
FNC and FNC Customer Use Only
Vol. ll, Page 480.3-9
Maintenance and Trouble Clearing
FJTU-320-515-480
3.8
B1ERR
3.9
B2ERR
Table 3-6: B1ERR (Error Data Generated)—Standing Condition
AID
Type
Direction
Probable Cause
Suggested Corrective Action
OC-3
TRMT/RCV
CONN-TSTSIG-OC3 has been
executed.
• Verify that the facility testing is
complete.
• Execute the DISC-TSTSIG-OC3
command.
OC-12
CONN-TSTSIG-OC12 has been
executed.
• Verify that the facility testing is
complete.
• Execute the DISC-TSTSIG-OC12
command.
Table 3-7: B2ERR (B2 Error Data Generated)—Standing Condition
AID
Type
Direction
Probable Cause
Suggested Corrective Action
EC1/HC
TRMT/RCV
CONN-TSTSIG-EC1 has
been executed.
•
Verify that the facility testing is complete.
•
Execute the DISC-TSTSIG-EC1 command.
OC3
TRMT/RCV
CONN-TSTSIG-OC3 has
been executed.
•
Verify that the facility testing is complete.
•
Execute the DISC-TSTSIG-OC3 command.
OC12
CONN-TSTSIG-OC12
has been executed.
•
Verify that the facility testing is complete.
•
Execute the DISC-TSTSIG-OC12 command.
DN 6163
TRMT
OC-3/
OC-12
ADDED
SIGNAL
150 ADM
DN 6163
TRMT
OC-3/
OC-12
ADDED
SIGNAL
150 ADM