fi-414110EOX2/S
CAN
S
NAP
C
ONSUMABLE
R
EPLACEMENT
AND
C
LEANING
I
NSTRUCTIONS
10
•
Turn Scanner power off.
•
Open the ADF cover by
pressing the ADF button.
Disconnect the AC power
plug. Let the scanner cool
for at least 15 minutes after
operation. This is to prevent
burns to your skin as the
lamps will heat the surface
of the glass in the feed path.
•
Use F1 Cleaner (90% or
higher Isopropyl Alcohol) on
a lint free cloth and clean the
areas shown in the drawing
to the right. (See following
steps to clean properly)
•
Clean the Pad Assembly
using a downward stroke in
the direction shown to the
right with the lint free cloth
moistened lightly with F1
Cleaner (90% or higher
Isopropyl Alcohol).
C
LEANING
THE
ADF
WITH
L
INT
-F
REE
C
LOTHS
Note:
The glass surface inside the fi-4110EOX2 ADF becomes hot during
scanner operation. Before performing this cleaning turn off the scanner
and disconnect the AC adapter from the power outlet, wait at least 15
minutes for the scanner to cool.
C
LEANING
THE
P
AD
A
SSEMBLY
.
ADF
button
Front of
Scanner
ADF
Sheet Guide (white
part also on ADF
side).
Pad
Assy
Plastic
Rollers (4)
Feed Rollers (2)
Pick Roller
Eject Rollers
(2)
ADF Glass
Pick Arm
Pick
spring
Clean the Rubber Portion
in Direction of Arrows
Pick
Arm
Pick
Spring
Pad
Assy.