
Chapter 2 Setup
>
2.3 Setting Items
ETERNUS Disk storage systems ETERNUSmgr User Guide -Introduction-
20
Copyright 2009 FUJITSU LIMITED
P2X0-0202-04ENZ0
When the actual polling exceeds the scheduled polling time:
■
Target Type
Sets the target device type. Two parameters are provided: TARGET_TYPE and TARGET_FLAG
These parameters cannot be omitted. ETERNUSmgr will not start if these parameter have not
been set.
[Parameter]
TARGET_TYPE (up to 256 characters)
[Example]
Any character string can be used to describe the target device type.
When the type of target device is ETERNUS2000:
TARGET_TYPE=ETERNUS2000
■
Target Flag
Set to either 1, 2 or 4 according to the Target Type being monitored.
[Parameter]
TARGET_FLAG (1, 2 or 4)
1: ETERNUS3000, ETERNUS GR710, GR720, GR730
2: ETERNUS6000, ETERNUS GR740, GR820, GR840
4: ETERNUS DX400 series, ETERNUS DX8000 series, ETERNUS2000, ETERNUS4000,
ETERNUS8000
Unless there is some special reason to change this parameter, it is
recommended to keep the default. For this reason the parameter is initially
commented out.
400 sec
150 sec
150 sec
450 sec
300 sec
300 sec
300 sec
300 sec
Schedule
recalculated
Scheduled polling
interval
Actual polling
interval
Per schedule
Schedule
recalculated
Scheduled
start NG
Delayed start
Holding
•
Note that even if the TARGET_TYPE and the TARGET_FLAG settings
are different, ETERNUSmgr operations are not affected.
•
Although any character string can be set in TARGET_TYPE, it is
recommended to set one of the correct target device types ("ETERNUS
DX400", ETERNUS DX8000", "ETERNUS2000", "ETERNUS4000",
"ETERNUS8000", "ETERNUS3000", "ETERNUS6000", "GR710",
"GR720", "GR730", "GR740", "GR820", or "GR840"). The character
string in TARGET_TYPE is used when the administrator is notified by E-
mail, and in the alarm history files.