Chapter 6 Operation Change
6.2 When Changing the Communication Environment
ETERNUS VSS Hardware Provider 2.1 User’s Guide
Copyright 2012 FUJITSU LIMITED
P3AM-4582-03ENZ0
48
6.2
When Changing the Communication Environment
When changing the following communication environment settings, change the communication service
(ETERNUS VSS Hardware Provider Communication Server service) operation.
•
The IP address of the backup server
•
The port number of the backup server
Change the settigs for a backup server first, then a production server as follows.
■
Backup server
●
Changing the communication environment setting
•
For Windows Server 2008
To start the "Communication Environment Setup command", click the [Start] button – [All Programs]
– [ETERNUS VSS Hardware Provider] – [Communication Environment Setup].
-
For a Server Core environment
Execute the "Communication Environment Setup Command".
For details, refer to
"8.8 Communication Environment Setup Command (stxvsetcommu)" (page
•
For Windows Server 2012
To start the "Communication Environment Setup command", click the [Start] icon – [Communication
Environment Setup].
-
For a Server Core environment
Execute the "Communication Environment Setup Command".
For details, refer to
"8.8 Communication Environment Setup Command (stxvsetcommu)" (page
●
Changing the firewall settings
Remove the changed port number from the firewall targets.
●
Restarting the ETERNUS VSS Hardware Provider Communication Server service
When a port number was changed, restart the ETERNUS VSS Hardware Provider Communication
Server service.
Restart it using one of the following procedures.
-
Reboot the backup server
-
Restart the ETERNUS VSS Hardware Provider Communication Server service in the [Service]
window of the backup server.