![Fujitsu ETERNUS HX2000 Series Installation And Cabling Manual Download Page 43](http://html.mh-extra.com/html/fujitsu/eternus-hx2000-series/eternus-hx2000-series_installation-and-cabling-manual_118346043.webp)
| How to read a worksheet to cable controller-to-stack connections for multipathed connectivity |
Procedure
1.
Cable port pair 1a/2b on each controller to stack 1:
a) Cable controller 1 port 1a to stack 1, first shelf IOM A port 1.
b) Cable controller 2 port 1a to stack 1, first shelf IOM B port 1.
c) Cable controller 1 port 2b to stack 1, last shelf IOM B port 3.
d) Cable controller 2 port 2b to stack 1, last shelf IOM A port 3.
2.
Cable port pair 1c/2d on each controller to stack 2:
a) Cable controller 1 port 1c to stack 2, first shelf IOM A port 1.
b) Cable controller 2 port 1c to stack 2, first shelf IOM B port 1.
c) Cable controller 1 port 2d to stack 2, last shelf IOM B port 3.
d) Cable controller 2 port 2d to stack 2, last shelf IOM A port 3.
43