Chapter 4 Function/System Settings and Display
4.4 Miscellaneous > set power-synchronization
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED
P2X0-1030-09ENZ0
571
set power-synchronization
This command configures the way in which the shutdown function interacts with the external sensor.
■
Syntax
■
Parameter
set power-synchronization [-cm { 0 | 1 | all | none }] [-svc { 0 | 1 | all | none }]
[-auto-power {enable | disable}] [-resume-power {enable | disable}] [-shutdown-time
shutdown_time
]
[-preset { power-sync | pman | manual}] [-power-fail-signal { positive | negative }]
[-low-battery-signal { positive | negative }] [-ups-shutdown-signal { positive | negative }]
[-ups-shutdown { enable | disable }]
-cm
Optional. This parameter specifies which controller module connects to the external sensor.
The connection method conforms to the RS-232C standard. If omitted, the existing setting is
not changed. This can only be set for ETERNUS DX80 S2/DX90 S2 and ETERNUS DX410 S2/
DX440 S2.
0
Controller module #0
1
Controller module #1
all
Both Service Controller #0 and Service Controller #1
none
No connection. If selected, only "-auto-power" and "-resume-power" from the
parameters that follow can be selected.
-svc
Optional. This parameter specifies which service controller connects to the external sensor. The
connection method conforms to the RS-232C standard. If omitted, the existing setting is not
changed. This parameter can only be set for the ETERNUS DX8700 S2.
0
Service Controller #0
1
Service Controller #1
all
Both Service Controller #0 and Service Controller #1
none
No connection.
-auto-power
Optional. If "enable" is specified, the system power is turned on when an AC power supply is
detected. The default value is set to disable.
enable
Enabled.
disable
Disabled.
-resume-power
Optional. If "enable" is specified, the system power is turned on when an AC power supply is
detected after the ETERNUS DX Disk storage system is shutdown due to a power outage. The
default value is set to disable.
enable
Enabled.
disable
Disabled.