background image

Contents 

1 Preparing for installation ·········································································· 1-1

 

Safety recommendations ································································································································ 1-1

 

General safety recommendations ··········································································································· 1-1

 

Electricity safety ······································································································································ 1-1

 

Moving safety ·········································································································································· 1-1

 

ESD prevention ······································································································································· 1-2

 

Laser safety ············································································································································· 1-2

 

Examining the installation site ························································································································· 1-2

 

Weight support ········································································································································ 1-2

 

Temperature ············································································································································ 1-2

 

Humidity ·················································································································································· 1-3

 

Cleanliness ·············································································································································· 1-3

 

EMI ·························································································································································· 1-3

 

Grounding ··············································································································································· 1-4

 

Power ······················································································································································ 1-4

 

Cooling ···················································································································································· 1-4

 

Space ······················································································································································ 1-5

 

Installation accessories ··························································································································· 1-5

 

 

Summary of Contents for S12500R-2L

Page 1: ...ty recommendations 1 1 Electricity safety 1 1 Moving safety 1 1 ESD prevention 1 2 Laser safety 1 2 Examining the installation site 1 2 Weight support 1 2 Temperature 1 2 Humidity 1 3 Cleanliness 1 3...

Page 2: ...wet floors Locate the emergency power off switch in the room before installation so you can quickly shut power off when an electrical accident occurs Remove all external cables including power cords b...

Page 3: ...owing requirements Weight support Make sure the floor or ground at the installation site can support the combined weight of the device and the rack The total weight of the device includes the chassis...

Page 4: ...electrostatic adsorption which causes poor contact of metal components and contact points In the worst case electrostatic adsorption can cause communication failure Table1 3 Dust concentration limit...

Page 5: ...wer as required by the device 1 Calculate the system power consumption The system power consumption varies by module types and quantities For more information about the system power consumption see Mo...

Page 6: ...R 2L Height 133 mm 5 24 in 3 RU Width 440 mm 17 32 in Chassis depth 895 mm 35 24 in Total depth 1013 m 39 88 in 104 mm 4 09 in from the rack facing surface of the mounting brackets to the front ends o...

Page 7: ...ne unit SEU also called MPU filler panel 2 2113A0YV S12500R 2L interface module filler panel 1 2124A01H S12500R 2L interface module protective blank panel 1 2114A0A4 S12500R 2L power supply filler pan...

Page 8: ...1 7 Product code Description Quantity 04042967 Console cable 1...