Chapter 3 Configuration Settings and Display
3.3 RAID Group Management > set raid-group
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED
P2X0-1030-09ENZ0
114
set raid-group
This command changes the information of an existing RAID group.
■
Syntax
■
Parameter
set raid-group {-rg-number
rg_number
| -rg-name
rg_name
} [-name
name
]
[-assigned-cm {0|1|cm0cpu0|cm0cpu1|cm1cpu0|cm1cpu1| cm2cpu0|
cm2cpu1|cm3cpu0|cm3cpu1| cm4cpu0|cm4cpu1|cm5cpu0|cm5cpu1|
cm6cpu0|cmc6pu1|cm7cpu0|cm7cpu1|auto}]
[-key-group {enable|disable}]
-rg-number
or
-rg-name
This parameter specifies RAID group identifiers.
Only one RAID group identifier can be specified when changing a RAID group alias name. One
or more RAID group identifiers can be specified when changing the assigned CM. For details,
refer to
"1.2.8 RAID Group Syntax" (page 22)
.
-name
Optional. This parameter specifies the new RAID group name. If this parameter is omitted, the
name is not changed. For details, refer to
"1.2.4 Alias Name Syntax" (page 20)
.
-assigned-cm
Optional. This parameter specifies the assigned controller module number of the RAID group. If
"auto" is specified, the fixed controller, which is calculated automatically by the system, is
assigned. If this parameter is omitted, the assigned CM is not changed.
For the ETERNUS DX80 S2/DX90 S2:
0 Controller
module#0
1 Controller
module#1
auto
Automatically (default)
For the ETERNUS DX410 S2/DX440 S2 and ETERNUS DX8100 S2:
cm0cpu0
Controller module#0 CPU#0
cm0cpu1
Controller module#0 CPU#1
cm1cpu0
Controller module#1 CPU#0
cm1cpu1
Controller module#1 CPU#1
auto
Automatically (default)