1. ETERNUS AX/HX Installation
Installation Specifications
Site Planning Guide
13
*6:
For details about the sound level of the drive shelf, refer to
"Table 5 Sound Level of the Drive Shelf" (page 13)
.
Table 5
Sound Level of the Drive Shelf
Table 6
Efficiency and Power Factor of the Power Supply Unit
*1:
Indicates the rated load against the rated output of the PSU.
ETERNUS HX2100/HX2200
Each installation specification is shown below.
•
Installation specifications:
•
Sound level of the drive shelf:
•
Efficiency and the power factor of the power supply unit:
Table 7
Installation Specifications (ETERNUS HX2100/HX2200)
DS224C
NS224
Sound pressure level
51 dBA
49.8 dBA
Sound power level
6.9 B
6.4 B
Component name
80PLUS®
Efficiency
Power factor
Output
Shelf
20 % (*1)
50 % (*1)
100 % (*1)
50 % (*1)
ETERNUS AX4100
Platinum
93.45 %
94.18 %
91.43 %
1.000
Single output
DS224C drive shelf
91.8 %
94.2 %
92.7 %
0.980
NS224 drive shelf
93.45 %
94.18 %
91.43 %
1.000
Item
ETERNUS HX2100
ETERNUS HX2200
Dimensions
(W
×
D
×
H)
3.5" type controller shelf
480
×
508
×
87 mm (2U)
-
2.5" type controller shelf
-
480
×
483
×
85 mm (2U)
DS212C 3.5" type drive shelf
480
×
505
×
87 mm (2U)
DS224C 2.5" type drive shelf
480
×
484
×
85 mm (2U)
DS460C 60-drive type drive shelf
486
×
922
×
176 mm (4U)
Power distribution unit (2U) (*1)
(485
×
123
×
44 mm)
×
2
Maximum weight
(*2) (*3)
3.5" type controller shelf
28.8 kg (32.8 kg)
-
2.5" type controller shelf
-
27.6 kg (31.6 kg)
DS212C 3.5" type drive shelf
28.7 kg (32.7 kg)
DS224C 2.5" type drive shelf
24.4 kg (28.4 kg)
DS460C 60-drive type drive shelf
112 kg (116 kg)
Power distribution unit (2U) (*1)
(3.0 kg)
×
2
Power
Voltage
AC 100 – 120V, AC 200 – 240V
Phase
Single
Frequency
50 Hz / 60 Hz
Summary of Contents for ETERNUS AX Series
Page 68: ......