
6.2 Address Translation
C141-E104-03EN
6-7
6.2 Address Translation
When the IDD receives any command which involves access to the disk medium,
the IDD always implements the address translation from the logical address (a
host-specified address) to the physical address (logical to physical address
translation).
Following subsections explains the CHS translation mode.
6.2.1 Default parameters
In the logical to physical address translation, the logical cylinder, head, and sector
addresses are translated to the physical cylinder, head, and sector addresses based
on the number of heads and the number of sectors per track which are specified
with an INITIALIZE DEVICE PARAMETERS command. This is called as the
current translation mode.
If the number of heads and the number of sectors are not specified with an
INITIALIZE DEVICE PARAMETERS command, the default values listed in
Table 6.1 are used. This is called the default translation mode. The parameters in
Table 6.1 are called BIOS specification.
Table 6.1 Default parameters
MHL2300AT
MHM2200AT
MHM2150AT
MHM2100AT
Number of cylinders
16,383
16,383
16,383
16,383
Number of heads
16
16
16
16
Number of sectors/track
63
63
63
63
Formatted capacity (MB)
30,005.82
20,003.88
15,103.03
10,056.13
As long as the formatted capacity of the IDD does not exceed the value shown on
Table 6.1, the host can freely specify the number of cylinders, heads, and sectors
per track.
Generally, the device recognizes the number of heads and sectors per track with
the INITIALIZE DEVICE PARAMETER command. However, it cannot
recognize the number of cylinders. In other words, there is no way for the device
to recognize a host access area on logical cylinders. Thus the host should manage
cylinder access to the device.
The host can specify a logical address freely within an area where an address can
be specified (within the specified number of cylinders, heads, and sectors per
track) in the current translation mode.
The host can read an addressable parameter information from the device by the
IDENTIFY DEVICE command (Words 54 to 56).
Parameters
(logical)
Summary of Contents for DISK DRIVES MHL2300AT
Page 1: ...C141 E104 03EN MHL2300AT MHM2200AT MHM2150AT MHM2100AT DISK DRIVES PRODUCT MANUAL ...
Page 3: ...This page is intentionally left blank ...
Page 5: ...This page is intentionally left blank ...
Page 9: ...This page is intentionally left blank ...
Page 11: ...This page is intentionally left blank ...
Page 13: ...This page is intentionally left blank ...
Page 37: ...This page is intentionally left blank ...
Page 40: ...3 1 Dimensions C141 E104 03EN 3 3 Figure 3 1 Dimensions MHM series 2 2 ...
Page 52: ...3 4 Jumper Settings C141 E104 03EN 3 15 Figure 3 16 Example 2 of Cable Select drive drive ...
Page 53: ...This page is intentionally left blank ...
Page 77: ...This page is intentionally left blank ...
Page 185: ...Interface 5 108 C141 E104 03EN Figure 5 10 Data transfer timing ...
Page 223: ...This page is intentionally left blank ...
Page 227: ...This page is intentionally left blank ...
Page 229: ...This page is intentionally left blank ...
Page 232: ......