30
Technical Manual
D3034
(RX100
S7)
Features
The LEDs have the following meaning:
LED Indicator
Meaning
A - CSS
(Customer Self
Service)
off
no error (CSS component)
yellow on
indicates a prefailure (CSS component)
yellow flashing indicates a failure (CSS component)
B - GEL
(Global Error
LED)
off
no error (non CSS component)
orange on
indicates a prefailure (non CSS
component)
orange flashing indicates a failure of a non CSS
component.
Reasons for a failure may be:
– over temperature measured by one of
the sensors
– sensor is defective
– CPU error
– software detected an error
C - Identification blue on
server is identified via the ServerView
Operations Manager or by ID button
blue flashing
local monitor off
D - Memory
off
memory module running
orange on
memory module failure
E - CPU
off
CPU okay
orange on
CPU failure
F - System fan
off
fan running
orange on
fan failure
G - PCI card
off
PCI card okay
orange on
PCI card failure (PCI card installed on riser
card)
H - iRMC
off
iRMC S3 inactive
green flashing
iRMC S3 okay