Technical Manual

 D3034 

(RX100 

S7)

Features

TPM (option)

The system board can be equipped with a TPM (Trusted Platform Module) by 
the manufacturer or by an add-on kit. This module enables programs from third 
party manufacturers to store key information (e.g. drive encryption using 
Windows Bitlocker Drive Encryption).

The TPM is activated via the BIOS system (for more information, refer to the 
BIOS manual).

V

CAUTION!

– When using the TPM, note the program descriptions provided by the 

third party manufacturers.

– You must also create a backup of the TPM content. To do this, follow 

the third party manufacturer's instructions. Without this backup, if the 
TPM or the system board is faulty you will not be able to access your 
data.

– If a failure occurs, please inform your service about the TPM 

activation before it takes any action, and be prepared to provide them 
with your backup copies of the TPM content.

Summary of Contents for D3034

Page 1: ...Technical Manual English System Board D3034 for PRIMERGY RX100 S7 Technical Manual Edition August 2012 ...

Page 2: ...ight and Trademarks Copyright 2011 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers Ê The contents of this manual may be revised without prior notice Ê Fujitsu assumes no liability for damages to third party copyrights or other rights...

Page 3: ...hese components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reached more quickly if for example the product is used in a hot environment The custo...

Page 4: ...mputer issued by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain such technology should not be exported from Japan or transferred to n...

Page 5: ... market Shielded LAN cables should be used in this product Only for the Japanese market I Although described in this manual some sections do not apply to the Japanese market These options and routines include USB Flash Module UFM CSS Customer Self Service ...

Page 6: ...Technical Manual D3034 RX100 S7 ...

Page 7: ...nvironmental protection 12 3 Features 15 3 1 Overview 17 3 2 Main memory 21 3 2 1 Module population 21 3 2 1 1 Types of memory modules 21 3 2 1 2 Modes of operation 22 3 3 PCI slots 23 3 4 Screen resolution 25 3 5 Temperature system monitoring 26 3 6 Connectors and indicators 27 3 6 1 System board 27 3 6 2 Connector panel 31 3 7 Settings 33 3 7 1 Jumper 33 ...

Page 8: ...Technical Manual D3034 RX100 S7 Contents ...

Page 9: ...ServerView Suite DVD 2 The PRIMERGY ServerView Suite DVD 2 is part of the PRIMERGY ServerView Suite supplied with every server PRIMERGY Abbreviations and Glossary can also be found on the PRIMERGY ServerView Suite DVD 2 Model lines for RX100 S7 There are two model lines for the RX100 S7 server RX100 S7 RX100 S7p I For the European market You can identify the model line by the model name RX100 S7p ...

Page 10: ... menu items Quotation marks indicate names of chapters and terms that are being emphasized Ê describes activities that must be performed in the order shown V CAUTION pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data I indicates additional information notes and tips ...

Page 11: ...e Manual of your server When handling the system board refer to the specific notes on safety in the Upgrade and Maintenance Manual of your server 2 1 CE certificate of conformity The system board complies with the requirements of the EC directives 2004 108 EC regarding Electromagnetic Compatibility and 2006 95 EC Low Voltage Directive This is indicated by the CE marking CE Communauté Européenne Co...

Page 12: ...tantly switched on should be switched off until they are needed as well as during long breaks and after completion of work Packaging information This packaging information doesn t apply to the Japanese market Do not throw away the packaging You may need it later for transporting the system If possible the equipment should only be transported in its original packaging Information on handling consum...

Page 13: ...used devices manual via your local Fujitsu branch or from our recycling center in Paderborn Fujitsu Technology Solutions Recycling Center D 33106 Paderborn Tel 49 5251 525 1410 Fax 49 5251 525 32 1410 The device must not be disposed of with domestic waste This device is labeled in compliance with European directive 2002 96 EC on waste electrical and electronic equipment WEEE This directive sets th...

Page 14: ...14 Technical Manual D3034 RX100 S7 Important information ...

Page 15: ...s Intel XEON E3 1200v2 processor series Intel Pentium Celeron processor series Intel Core i3 processor series Main Memory DDR3 UDIMM with 1333 MHz speed up to 21 GB s bandwidth in dual channel mode and 10 6 GB s in single channel mode DDR3 UDIMM with 1600 MHz speed up to 25 6 GB s bandwidth in dual channel mode and 12 8 GB s in single channel mode PCI slots 1x PCIe x4 Gen 2 internal only for SAS c...

Page 16: ...e model line by the model name RX100 S7p printed on the identification rating plate and on the ID card I For the Japanese market RX100 S7p is not used as the model name in the Japanese market You can identify the model line by the product number The product number PYR10Pxxx means RX100 S7p ...

Page 17: ...le bit error correction Chips on the system board Intel C202 chip set Gigabit Ethernet controller Intel 82574L shared LAN Gigabit Ethernet controller Intel 82579LM standard LAN 8 MB Flash BIOS onboard iRMC S3 Server Management Controller with integrated graphics controller and associated management LAN connector Internal connectors 1x front panel connector 1x power supply connector 24 pin 12V 1x p...

Page 18: ...ectors rear side 1x serial connector COM1 4x USB 2 0 connectors 1x video connector VGA 3x RJ45 LAN connectors PCI slots 1 x PCI Express x16 slot for a riser card 1 x PCI Express x1 slot for a riser card 1 x PCI Express x4 slot for a riser card Power management ACPI states S0 S4 S5 3 3 V standby power on the PCI Express slots on off sleep wake by power button on off by software wake by RTC external...

Page 19: ...M logo CPU memory disable Environmental protection battery in holder Form factor 235 5 mm W x 255 5 mm D CSS Customer Self Service This system board supports the CSS functionality You will find a description of CSS functionality in the operating manual of your server USB Flash Module option The system board can be equipped with an USB Flash Module UFM by the manufacturer or by an add on kit The mo...

Page 20: ...OS system for more information refer to the BIOS manual V CAUTION When using the TPM note the program descriptions provided by the third party manufacturers You must also create a backup of the TPM content To do this follow the third party manufacturer s instructions Without this backup if the TPM or the system board is faulty you will not be able to access your data If a failure occurs please inf...

Page 21: ... first Within all channels memory slot 1 must be populated prior to slot 2 Install memory modules within a channel in descending order of capacity higher capacity in slot 1 lower capacity in slot 2 3 2 1 1 Types of memory modules UDIMM memory modules Technology DDR3 1066 1333 1600 unbuffered single rank SR or dual rank DR UDIMM memory modules with ECC Support for up to 4 UDIMM memory modules Total...

Page 22: ...ween the two channels the system board will run in dual channel asymmetric mode Regardless of the mode all DIMMs will run at the highest common frequency that is allowed by the SPD Data of the DIMMs and the max speed of the selected configuration Single channel mode is used when 1 memory module is populated in DIMM 1A Configuration per channel Max speed DIMM 2 DIMM 1 1 DDR3 1333 1600 empty SR DR 2...

Page 23: ...m Slot 3 PCI Express x16 Low profile slot maximum length 170 mm SATA4 BP PWR PCIE16 PCIE4 PCIE1 SATA2 SATA1 SATA3 BP SGPIO PCH iRMC S3 SATA5 ODD PWR1 Riser card x1 DIMM1B DIMM2A DIMM1A Riser card x16 DIMM2B CPU VGA Battery TPM COM1 Riser card x4 USB1 2 Managem LAN Shared LAN Standard LAN UFM PWR2 USB3 4 FAN5 FAN4 FAN3 FAN2 FAN1 FRONT LAN Slot3 Slot2 Slot1 FAN SYS FRONT VGA FRONT PANEL J22 J26 Rese...

Page 24: ... interrupts through messages The interrupts are defined by the system design The following interrupt signals are used in the system Slot device Property Interrupt signal VGA iRMC S3 graphic PCI INTA LAN Intel 82574L PCI INTA LAN Intel 82579LM PCI INTA Slot 3 PCIe x16 PCI_INTA PCI_INTB PCI_INTC PCI_INTD Slot 2 PCIe x1 PCI_INTA PCI_INTB PCI_INTC PCI_INTD Slot 1 PCIe x4 PCI_INTA PCI_INTB PCI_INTC PCI...

Page 25: ...ntegrated in the iRMC S3 integrated Remote Management Controller If you are using an external graphic controller you will find details of supported screen resolutions in the operating manual or technical manual supplied with the graphic controller Screen resolution pixel Maximum refresh rate Hz Max number of colours 640x480 85 32 bit 800x600 85 32 bit 1024x768 75 32 bit 1152x864 60 16 bit 1280x102...

Page 26: ...ture sensors Fan monitoring The power supply unit and system fans are monitored Fans that are no longer available blocked or stuck fans are detected Fan control The fans are regulated according to temperature Voltage monitoring When voltage exceeds warning level high or falls below warning level low an alert will be generated System Event Log SEL All monitored events of the system board are signal...

Page 27: ...PCIE4 PCIE1 SATA2 SATA1 SATA3 BP SGPIO PCH iRMC S3 SATA5 ODD PWR1 Riser card x1 DIMM1B DIMM2A DIMM1A Riser card x16 DIMM2B CPU VGA Battery TPM COM1 Riser card x4 USB1 2 Managem LAN Shared LAN Standard LAN UFM PWR2 USB3 4 FAN5 FAN4 FAN3 FAN2 FAN1 FRONT LAN Slot3 Slot2 Slot1 FAN SYS FRONT VGA FRONT PANEL J22 J26 Reset PIN1 GND PIN2 1 Indicate CSS CSS 1 2 3 4 0 5 6 7 8 9 ...

Page 28: ... 6 PWR1 Power supply connector 12V 7 SATA 5 ODD SATA connector for optical drive 8 CSS I2C signaling connector for optional LocalView Service Panel 9 FAN SYS Power connector for system fans and ODD 10 Reset GND Reset connector optional 11 FRONT PANEL Front panel connector 12 SATA 3 SATA HDD connector 13 FRONT VGA Connector for optional front VGA 14 SATA 1 SATA HDD connector 15 SATA 4 SATA HDD conn...

Page 29: ...e disconnected it is possible to indicate the faulty component by pressing the CSS indicate button No Description 1 CSS indicate button SATA4 BP PWR PCIE16 PCIE4 PCIE1 SATA2 SATA1 SATA3 BP SGPIO PCH iRMC S3 SATA5 ODD PWR1 Riser card x1 DIMM1B DIMM2A DIMM1A Riser card x16 DIMM2B CPU VGA Battery TPM COM1 Riser card x4 USB1 2 Managem LAN Shared LAN Standard LAN UFM PWR2 USB3 4 FAN5 FAN4 FAN3 FAN2 FAN...

Page 30: ...e of a non CSS component Reasons for a failure may be over temperature measured by one of the sensors sensor is defective CPU error software detected an error C Identification blue on server is identified via the ServerView Operations Manager or by ID button blue flashing local monitor off D Memory off memory module running orange on memory module failure E CPU off CPU okay orange on CPU failure F...

Page 31: ...ansmission rates of 10 Mbit s 100 Mbit s and 1 Gbit s The shared LAN controller also supports WOL functionality by means of Magic Packet It is also possible to start a system via a LAN without a separate boot hard disk drive No Description 1 Global error indicator orange CSS indicator yellow ID indicator blue description see preceding section 2 Management LAN connector for iRMC S3 server managemen...

Page 32: ...s two LEDs which display the speed of the connection and its status Figure 7 LAN LEDs LED Indicator Description 1 LAN speed Steady yellow signal in the event of a LAN transfer rate of 1 Gbit s Steady green signal in the event of a LAN transfer rate of 100 Mbit s Remains dark in the event of a LAN transfer rate of 10 Mbit s 2 LAN link transfer Steady green signal when a LAN connection exists Remain...

Page 33: ... short clear password and apply the default BIOS settings J26 BIOS RECOVER 1 2 normal operation default 2 3 recovery mode SATA4 SATA2 SATA1 SATA3 PCH SATA5 ODD Riser card x1 DIMM1B DIMM2A DIMM1A DIMM2B VGA Riser card x4 USB1 2 Standard LAN UFM USB3 4 Slot2 Slot1 FAN SYS FRONT VGA FRONT PANEL J22 J26 Reset PIN1 GND PIN2 1 Default J22 J26 Indicate CSS CSS ...

Page 34: ...34 Technical Manual D3034 RX100 S7 Features ...

Reviews: