Powering the Application Unit on and off via the iRMC

Application Units

46

 

 U41857-J-Z125-1-76

Ê

In the navigation select 

Power Management  

 

Power ON/OFF

Ê

In the 

Power Control 

group activate the option you require (

Graceful Reset (Reboot)

 is 

selected in the example)

Ê

Click 

Apply

Ê

Reply to the subsequent question by clicking 

Confirm

.

You can observe the status of the AU in the overview of the units:

Ê

Select 

Hardware

 

→ 

Server (SE<model>

Units

 tab.

 

Alternatively, depending on the status of the AU you can start up or shut down the AU's 
Native system in the SE Manager: 

Ê

In the 

Units

 icon, click the 

Power on

/

Power off

 icon, and if you want to shut down the AU 

select the 

Shutdown

 action. 

You can also execute the action which is currently permissible under 

Systems

 

 

<unit 

name>(AU<model>)

 in the 

Action

 group of the 

Operation

 tab. 

Summary of Contents for BS2000 SE300

Page 1: ...Edition September 2015 English SE700 SE500 SE300 Quick Guide FUJITSU Server BS2000 User Guide Valid for M2000 V6 0A V6 1A X2000 V6 0A V6 1A HNC V6 0A V6 1A ...

Page 2: ...ee bleach Copyright 2015 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The Xen mark is a trademark of Citrix Systems Inc which manages the mark on behalf of the Xen open source community The Xen mark is registered with the U S Pate...

Page 3: ...d networks 11 2 1 Hardware 11 2 2 Architecture of SE servers 12 2 3 Networks 13 2 4 Operating the SE Manager 15 2 4 1 Calling the SE Manager 15 2 4 1 1 Logging in 16 2 4 1 2 Logging out 17 2 4 2 Working with the SE Manager 17 2 4 2 1 Main window 18 2 4 2 2 Terminal window 21 2 4 2 3 Calling an object or function in the SE Manager 22 2 4 2 4 Navigation 22 2 4 2 5 Authorizations 23 2 4 2 6 Calling t...

Page 4: ...SU 390 30 3 5 Starting up BS2000 SU x86 35 3 6 Opening and terminating BS2000 dialog 38 3 7 Shutting down BS2000 via the BS2000 console 40 3 8 Powering off Server Units and other units 41 3 9 Messages on the BS2000 console 42 4 Setting the system time or configuring the NTP 43 5 Application Units 45 5 1 Powering the Application Unit on and off via the iRMC 45 5 2 Embedding an application or link i...

Page 5: ...ine succeeds the tried and tested S and SQ server lines integrating the advantages of both lines in an optimal manner The heart of the SE series is formed by the 390 based Server Units the x86 based Server Units the Net Unit and the Management Unit MU All components are integrated into a standard 19 rack and are supplied to customers ready to use With its newly developed processors and appreciably...

Page 6: ...e concepts for stable system operation tested on the mainframe Selection of high quality server components Redundant hardware components Prepared operating concepts which also include high availability Comprehensive tests before release Comprehensive service concept The management interface which is uniform for all SE servers the SE Manager permits a view of all the system components involved and ...

Page 7: ... e g operator AU administrator etc to permit the assigned tasks to be performed This Quick Guide assumes the following Customer Support provides the customer with the SE server The desired BS2000 operating mode is set on each Server Unit A BS2000 system is configured and fully operational All necessary BS2000 devices are configured 1 2 Summary of contents Chapter 2 contains fundamental information...

Page 8: ...ing file on the BS2000 system SYSRME product version lang This file contains brief information on the Readme file in English or German lang E D You can view this information on screen using the SHOW FILE command or an editor The SHOW INSTALLATION PATH INSTALLATION UNIT product command shows the user ID under which the product s files are stored Additional product information Current information ve...

Page 9: ...CAUTION precede warning information In the interests of system and operating security you should always observe this information Ê The action which you must perform is indicated by this symbol italics Texts from the SE Manager e g menu name tab monospace System inputs and outputs monospaced semibold Statements which are entered via the keyboard are displayed in this font abc Variables which are re...

Page 10: ...er Unit with one or more x86 processors A distinction is made between the following SUs according to models SU300 for the Server Unit of the unit type SU x86 in SE300 optionally in SE500 and SE700 SU500 for the Server Unit of the unit type SU 390 in SE500 SU700 for the Server Unit of the unit type SU 390 in SE700 MU for the Management Unit The MU permits central user friendly and cross system mana...

Page 11: ...f BS2000 Native BS2000 or VM2000 An x86 based Server Unit SU x86 enables operation of BS2000 Native BS2000 or VM2000 XenVM operation with Linux or Windows guest systems is also possible as an option Application Units AUs AUs can be operated on the SE server An AU permits operation of applications under Linux Windows VMware or other hypervisors Net Unit For the SU 390 the Net Unit also contains HNC...

Page 12: ...um performance and security for internal communication in an SE server and for a connection to customer networks IP networks Redundant Management Unit MU with SE Manager Customer network Net Unit SE Server IP networks Management Unit MU with SE Manager Redundant Net Unit BS2000 Linux Windows Disk Tape Disk VMware Citrix Hyper V OVM Further optional peripherals VM2000 Xen VM2000 Windows Linux BS200...

Page 13: ...1 99 can be configured for internal private customer networks for SE servers Public management networks Management Administration Network Public MANPU for administrative access to the MU BS2000 systems and AUs Management Optional Network Public MONPU the additive administration network can be configured when required e g when AIS Connect is not to be operated via MANPU but over a separate network ...

Page 14: ...s for the various networks DANPU xx MANPU MONPU DANPR xx and MONPR xx can be further restricted at Net Unit level by means of the ACL Access Control List The base operating system of the HNC and SU x86 can only be reached over the internal networks and are thus protected from the customer networks In addition to the connections of the units to the switches of the Net Unit for use by the guest syst...

Page 15: ...0 V6 1 and higher the administrator can grant access to the MU applies for the SE Manager and CLI explicitly only for specific IP addresses or networks If your PC is not defined in the access list access is denied Ê Press the Enter key The connection is set up The login window is opened The login window provides access to the web application It has a different format from the other windows The log...

Page 16: ...M2000 V6 1A or higher operator XenVM administrator and AU administrator in M2000 V6 1A or higher The BS2000 administrator operator XenVM administrator and AU administrator roles have restricted rights which are tailored to their different task areas For an operator account you can extend the rights for granting individual authorizations e g access to particular BS2000 systems SVP access Details of...

Page 17: ...range from 5 through 60 minutes or exclude it Ê Click in the login information in the header area A list containing the menu item Individual settings opens Ê Click Individual settings The Change update cycle and session timeout dialog box opens in which you can enable disable the session timeout and set the timeout in the range from 5 to 60 minutes The individual setting is stored in the SE Manage...

Page 18: ...f the SE Manager session See section Terminal window on page 21 Dialog Wizard a window which opens when an action starts and closes again after the action has been completed It is also used to output error messages concerning the action being performed A wizard is a utility which takes you through a task in a number of steps dialog boxes Online help window a window which opens when the online help...

Page 19: ... via which you are currently operating the SE Manager unit name is the name of the Management Unit If a location is configured with SYSLOCATION location displays the entry If the field ends with the arrow icon redundant Management Units are available Click the field to obtain a list with links to the available Management Units c Displays the login information user account or if defined the person ...

Page 20: ...ate is suspended If the automatic update is active the rotating wheel is briefly displayed as an update icon in the rhythm of the update 4 Help icon for calling the SE Manager help on a context sensitive basis see page 23 5 a b The information is subdivided into groups in the example above 5a and 5b Each group contains one or more tables with properties of the objects displayed 6 Icons for trigger...

Page 21: ...h the context menu in the terminal window Cross window copy paste terminal window Windows under Windows Windows Copying with COPY context menu or CTRL C in the terminal window Pasting with Paste context menu or CTRL V in Windows Terminal window Copying with Copy context menu or CTRL C in Windows Pasting with PASTE context menu in the terminal window or via the menu bar of Firefox no CTRL V is poss...

Page 22: ...rea changes if you select another tab The selected menu item and the selected tab are highlighted by being displayed in bold black print against a blue or gray background Example Hardware Server unit name MU Service Update tab i The objects and functions which are displayed in the tree structure depend on the server component and the configuration 2 4 2 4 Navigation The navigation in the SE Manage...

Page 23: ...d in M2000 V6 1 and higher A BS2000 administrator sees the functions which are needed to operate BS2000 systems in the tree structure and also has the BS2000 related administrator authorizations An AU administrator sees the functions which are needed to operate the systems on AUs in the tree structure and also has the AU related administrator authorizations Overviews of the role specific tasks and...

Page 24: ...Operating the SE Manager Architecture of the SE servers and networks 24 U41857 J Z125 1 76 ...

Page 25: ...wering on the Management Unit remotely This section describes how you log in remotely on the iRMC integrated Remote Management Controller of the Management Unit and power on the MU via its user interface Ê Open a browser window on your administration PC Ê Enter the IP address of the iRMC of the MU I If the browser now displays a warning about the security certificate click Continue to this website...

Page 26: ...e default account admin is configured for the administrator on the iRMC of the MU admin is set as this account s password Change the password immediately after you have logged in for the first time Ê Click OK After a successful login the browser window displays the System Overview menu item of the iRMC s graphical user interface The System Status group shows that the MU is shut down Ê In the navig...

Page 27: ...Control content area enable the Power On option Ê Click Apply Ê Answer the question Do you really want the server to Power On by clicking Confirm The MU powers itself on and starts up Some minutes will pass before it is possible to log in on the SE Manager You can see in the console window when it is possible Ê Switch to the console window The current progress of the startup operation is displayed...

Page 28: ...put on the local console As soon as the system is ready you receive the login request Ê Enter admin or another administrator account as the account Ê Enter admin as the password admin is the password of the admin account when the system is supplied If it has already been changed or you are using a different password you must enter the current password see also Abschnitt Logging in auf Seite 16 Ê C...

Page 29: ... 390 and Application Units of the SE server Depending on the status you use the Units tab to power the required units on or off or reboot them Switching the Server Unit on Requirement The unit is powered off power status OFF Procedure Ê Click the Power on icon by the required Server Unit and confirm the action with Execute in the subsequent dialog box The powered off unit is powered on As soon as ...

Page 30: ...he HNC must be powered on Redundant existing HNCs should also be powered on 3 4 Starting up BS2000 SU 390 A Server Unit 390 is operated via the SVP Service Processor after it has been powered on SVP functions are operated under menu guidance on the SVP console using SVP frames i Some important SVP functions for instance for IPL or IORSF are also available directly on the SE Manager or can alternat...

Page 31: ...SU 390 U41857 J Z125 1 76 31 The SVP console window opens Ê Press the Enter key The MODE SELECTION FRAME appears i If the SVP has already been worked with the last frame used will appear You reach the MODE SELECTION FRAME by entering FR ML in the entry line ...

Page 32: ...ard is also available to you for making entries on the SVP console Click the keyboard icon at the top right to open the virtual keyboard Clicking the icon again closes the keyboard Enter the alphanumeric characters shown in the frame in the input fields marked by an arrow A detailed description of how to operate the SVP is provided in the Server Unit 390 Operating Manual 2 ...

Page 33: ...n differ from the IPL load device of the last IPL If necessary select a different load device under IPL DEVICE I Initial startup from the IPL load device requires a DIALOG startup LOAD FUNCTION 3 must be selected for this purpose Take note of the setting for PARMS This depends on the BS2000 operating mode set In VM2000 mode PARMS 1 must be set In Native BS2000 mode a blank must be entered there Ê ...

Page 34: ...s the message NSI0000 displays System ready startup of BS2000 has already been largely completed You can continue to observe the current BS2000 session on the console and when necessary react to system messages e g reply to a mount message For information on console messages which are issued by M2000 X2000 see Abschnitt Messages on the BS2000 console auf Seite 42 For more extensive administration ...

Page 35: ...verview tab When you click on the name of the BS2000 system the SE Manager switches to the Operation tab of the BS2000 system Ê In the Console and dialog group click Open on the BS2000 console function i The console mnemonic must be configured in the BS2000 OSD BC parameter file in the default case the console mnemonics C0 and C1 are defined If the browser now displays a warning about the security...

Page 36: ... 0 Back to main menu 1 Start BS2000 2 Start BS2000 dump IPL 3 Dump IOH memory 4 Report actual default parameters for IPL Please enter value Ê Enter 1 The menu containing the IPL functions for starting BS2000 is then displayed Start BS2000 0 Back to main menu 1 Execute with current parameters 2 Execute with preset parameters 3 Execute with current parameters and save into preset parameters Change p...

Page 37: ...umber of messages are output one after the other question messages can also quickly disappear The SHOW PENDING MSG or STATUS MSG command enables you to have all the open question messages displayed again As soon as the message NSI0000 displays System ready startup of BS2000 has already been largely completed You can continue to observe the current BS2000 session on the console and when necessary r...

Page 38: ... where the Operation tab of the BS2000 system which was previously started was most recently opened take note of Logging out because of a session timeout auf Seite 17 Ê In the Console and dialog group click Open in the BS2000 dialog function A BS2000 dialog window opens CN04 CONNECTED WITH MANLO1 DIALOG IND C JMS0150 INSTALLATION 390SU 700 20 BS2000 VERSION V190 HOST D020ZE01 PLEASE ENTER SET LOGO...

Page 39: ...ows to close the dialog window Ê Terminate your dialog task using the EXIT JOB command or LOGOFF BS2000 terminates your task and the connection to BS2000 is cleared Ê Respond to the request PLEASE ACKNOWLEDGE by pressing the Enter key Ê The main window of the terminal emulation opens Ê Enter e and press the Enter key to terminate terminal emulation The window is closed ...

Page 40: ...nsole window opens The console is loaded Ê Enter the SHUTDOWN command if necessary with specifications for the MODE and MESSAGE operands to warn the participants in the BS2000 dialog Ê Take note of the console messages and answer any question messages which are issued Output of the message EXC0557 SHUTDOWN PROCESSING COMPLETED indicates that shutdown of BS2000 has been completed Ê Close the consol...

Page 41: ... Units tab to power a unit on or off or reboot it Shutting down the unit or immediately powering it off Requirement You can power off a unit only when the unit is accessible i e the HW status is not NOT_ACCESSIBLE Procedure Ê Click the Power off icon by the required unit Ê In the dialog box which then appears select the option Shut down or Power off immediately and confirm the action with Execute ...

Page 42: ...000 OSD BC V10 0 and higher you can inquire response and any meaning texts for messages of M2000 X2000 using the HTML application System messages online at http manuals ts fujitsu com or on the BS2000 SoftBooks DVD i In BS2000 you can only inquire the message text meaning and response text for a message code with the HELP MSG INFORMATION command only if the message is stored in a BS2000 message fi...

Page 43: ...s a radio clock using NTP Network Time Protocol Effect on the time setting of the systems on the SE server The time settings of the other systems are synchronized with the system time of the Management Unit The Management Unit is the basic timer When changes are made to the time management which affect the Server Unit bear in mind that the time settings in BS2000 systems and of XenVMs that are sta...

Page 44: ... configuration click the Remove icon by the required NTP server in the Time synchronization with NTP server group and confirm the action i In the case of an SE server with redundant MU the MU with the index 1 should by default be entered as an NTP server on the MU with the index2 for details see the Operation and Administration manual 5 Changing the local time You can only change the local time if...

Page 45: ... as a Database Unit with the short name DBU87 Otherwise the short name is displayed In the case of an AU87 or DBU87 systems run on the individual partitions of the AU You operate a partition via the Management Board In the Operation tab you open the web interface of the Management Board instead of the iRMC in the Operation group for this purpose 5 1 Powering the Application Unit on and off via the...

Page 46: ...tion by clicking Confirm You can observe the status of the AU in the overview of the units Ê Select Hardware Server SE model Units tab Alternatively depending on the status of the AU you can start up or shut down the AU s Native system in the SE Manager Ê In the Units icon click the Power on Power off icon and if you want to shut down the AU select the Shutdown action You can also execute the acti...

Page 47: ...ined management applications In M2000 V6 1 and higher the functionality for connecting applications extends to AUs The independent links are then called user defined links and are managed in the User defined links group An application which can be integrated into the SE Manager infrastructure such as the OVM Manager is then called a user defined management application and is managed in the User de...

Page 48: ...Embedding an application or link in the SE Manager Application Units 48 U41857 J Z125 1 76 ...

Page 49: ...omprising several modules and the User Guides Operation and Administration and Security Manual 1 FUJITSU Server BS2000 SE700 SE500 SE300 Basic Operating Manual 2 FUJITSU Server BS2000 SE700 SE500 Server Unit 390 Operating Manual 3 FUJITSU Server BS2000 SE700 SE500 SE300 Server Unit x86 Operating Manual 4 FUJITSU Server BS2000 SE700 SE500 SE300 Additive Components Operating Manual 5 FUJITSU Server ...

Page 50: ...ure on BS2000 OSD XC The manuals for the system related software products which belong to the BS2000 OSD XC software package also apply Any additions to the manuals are described in the Readme files for the various product versions These Readme files are available at http manuals ts fujitsu com under the various products Current information version and hardware dependencies and instructions for in...

Page 51: ...42 IPL load device 33 37 iRMC 25 45 K KVP message class 42 L load device 33 37 logging in on the SE Manager 16 login window 15 M main window 18 Management Administration Network Public MANPU 13 Management Board 45 Management Control Network Local MCNLO 13 Management Control Network Private MCNPR 13 management network private 13 Public 13 Management Optional Network Private MONPR 13 Management Opti...

Page 52: ...logging in 16 navigation 22 online help 23 welcome page 16 SE server 11 SE300 10 SE500 10 SE700 10 Server Unit 11 SNX message class 42 SQ server 10 standard account password 16 26 SU Server Unit 10 SU 390 10 SU x86 10 SVP commands 36 SVR message class 42 T time setting 43 U unit powering off 41 powering on 29 user defined link 47 user defined management application 47 W welcome page SE Manager 16 ...

Reviews: