1. Error code
1-1. Error code table (Wired remote controller)
The operation, timer, and economy indicators operate according to the error contents.
For confirmation of the error contents, refer the flashing pattern as follows.
Error contents
Wired remote
controller
display
E: 11. Serial communication error (Serial reverse transfer error) (Outdoor unit)
11
E: 11. Serial communication error (Serial forward transfer error) (Indoor unit)
11
E: 12. Wired remote controller communication error (Indoor unit)
12
E: 18. External communication error (Indoor unit)
18
E: 23. Combination error (Outdoor unit)
23
E: 26. Address setting error in wired remote controller (Indoor unit)
26
E: 29. Connected unit number error (Indoor unit)
29
E: 32. Indoor unit main PCB error (Indoor unit)
32
E: 33. Indoor unit motor electricity consumption detection error (Indoor unit)
33
E: 35. MANUAL AUTO button error (Indoor unit)
35
E: 39. Indoor unit power supply error for fan motor (Indoor unit)
39
E: 3A. Indoor unit communication circuit (wired remote controller) error
3A
E: 41. Room temperature sensor error (Indoor unit)
41
E: 42. Indoor unit heat exchanger sensor error (Indoor unit)
42
E: 51. Indoor unit fan motor error (Indoor unit)
51
E: 53. Drain pump error (Indoor unit)
53
E: 62. Outdoor unit main PCB error (Outdoor unit)
62
E: 63. Inverter error (Outdoor unit)
63
E: 64. PFC circuit error (Outdoor unit)
64
E: 65. Trip terminal L error (Outdoor unit)
65
E: 71. Discharge thermistor error (Outdoor unit)
71
E: 72. Compressor thermistor error (Outdoor unit)
72
E: 73. Heat exchanger (Middle/Outlet) temperature thermistor error (Outdoor unit)
73
E: 74. Outdoor temperature thermistor error (Outdoor unit)
74
E: 77. Heat sink thermistor error (Outdoor unit)
77
E: 84. Current sensor error (Outdoor unit)
84
E: 86. High pressure switch error (Outdoor unit)
86
E: 94. Trip detection (Outdoor unit)
94
E: 95. Compressor motor control error (Outdoor unit)
95
E: 97. Outdoor unit fan motor error (Outdoor unit)
97
E: 99. 4-way valve error (Outdoor unit)
99
E: A1. Discharge temperature error (Outdoor unit)
A1
E: A3. Compressor temperature error (Outdoor unit)
A3
E: A5. Low pressure error (Outdoor unit)
A5
E: AC. Heat sink temperature error (Outdoor unit)
AC
1-1. Error code table (Wired remote controller)
- (03-1) -
1. Error code
TROUBLESHOOTING
TROUBLESHOOTING
Summary of Contents for AUXG36KRLB
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2020 11 16 SR_CH01_AU015EF_02 ...
Page 16: ...2 2 Outdoor unit 01 10 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 17: ...2 TECHNICAL DATA AND PARTS LIST 2020 11 16 SR_CH02_AU015EF_02 ...
Page 47: ...3 TROUBLESHOOTING 2020 06 04 SR_CH03_AU015EF_01 ...
Page 50: ......
Page 116: ...5 2 Outdoor unit 03 66 5 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 117: ...4 CONTROL AND FUNCTIONS 2020 06 04 SR_CH04_AU015EF_01 ...
Page 120: ......
Page 157: ...5 FILED WORKING 2020 06 04 SR_CH05_AU015EF_01 ...