![Fujitsu AUXG30KRLB Service Instruction Download Page 26](http://html.mh-extra.com/html/fujitsu/auxg30krlb/auxg30krlb_service-instruction_2343789026.webp)
¢
Sleep timer
If the sleep timer is set, the room temperature is monitored and the operation is stopped auto-
matically. If the operation mode or the set temperature is change after the sleep timer is set, the
operation is continued according to the changed setting of the sleep timer from that time on.
• In the cooling operation mode
When the sleep timer is set, the setting temperature is increased 1°C. It increases the setting
temperature another 1°C after 1 hour. After that, the setting temperature is not changed and
the operation is stopped at the setting time.
Set temperature rises
Ts: Set temperature
Stop of operation
Ts
+2°C
Set
60 min
+1°C
• In the heating operation mode
When the sleep timer is set, the setting temperature is decreased 1°C. It decreases the setting
temperature another 1°C every 30 minutes. Upon lowering 4°C, the setting temperature is not
changed and the operation is stopped at the setting time.
Set
Ts
-2°C
-1°C
-3°C
-4°C
Ts: Set temperature
30 min
30 min
30 min
Stop of operation
Set temperature rises
5-1. Wireless remote control
- (04-21) -
5. Timer operation control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Summary of Contents for AUXG30KRLB
Page 2: ...1 CONTROL AND FUNCTIONS 2020 06 01 SR_CH04_AU006EF_01 ...
Page 4: ...8 8 High temperature and high pressure release control 04 36 CONTENTS continued ...
Page 5: ......
Page 42: ...2 TROUBLE SHOOTING CASSETTE type INVERTER ...
Page 90: ...Jun 2020 Printed in Japan 3 3 17 Suenaga Takatsu ku Kawasaki 213 8502 Japan ...