REFRIGERANT
SYSTEM DIAGRAM
2-way valve
Strainer
Strainer
3-way valve
Muffler
Muffler
Pressure
switch
4-Way valve
Expansion valve
Heat exchanger
(Indoor unit)
Heat exchanger
(Outdoor unit)
Sub-accumulator
Compressor
Cooling flow
Heating flow
Refrigerant pipe diameter
[18]
Liquid : 1/4” (6.35 mm)
Gas : 1/2” (12.7 mm)
[24]
Liquid : 1/4” (6.35 mm)
Gas : 5/8” (15.88 mm)
4