- (02 - 07) -
OU
TDOOR
UNIT
AO
G1
2
-2
4
L
A
L
OU
TDOOR
UNIT
AO
G1
2
-2
4
L
A
L
This table is created using the maximum capacity.
MODEL
: AO
G14LALL
Height difference H
1 Indoor unit is higher than outdoor unit.
2 Indoor unit is lower than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
HEATING
Pipe length (m)
5
7.5
10
15
20
25
Height
difference H
(m)
1
Indoor unit is
higher than
outdoor unit.
15
-
-
-
0.918
0.891
0.862
10
-
-
0.981
0.918
0.891
0.862
7.5
-
1.000
0.981
0.918
0.891
0.862
5
1.000
1.000
0.981
0.918
0.891
0.862
0
1.000
1.000
0.981
0.918
0.891
0.862
2
Indoor unit is
lower than
outdoor unit.
-5
0.995
0.995
0.976
0.914
0.886
0.858
-7.5
-
0.993
0.974
0.912
0.884
0.856
-10
-
-
0.972
0.909
0.882
0.854
-15
-
-
-
0.900
0.873
0.845
COOLING
Pipe length (m)
5
7.5
10
15
20
25
Height
difference H
(m)
1
Indoor unit is
higher than
outdoor unit.
15
-
-
-
0.953
0.950
0.947
10
-
-
0.983
0.968
0.966
0.962
7.5
-
0.988
0.987
0.972
0.970
0.966
5
0.992
0.992
0.991
0.976
0.974
0.970
0
1.000
1.000
0.999
0.984
0.982
0.978
2
Indoor unit is
lower than
outdoor unit.
-5
1.000
1.000
0.999
0.984
0.982
0.978
-7.5
-
1.000
0.999
0.984
0.982
0.978
-10
-
-
0.999
0.984
0.982
0.978
-15
-
-
-
0.984
0.982
0.978
H
H