background image

En-9

<In the Heating mode> Is  [  ] indicator blinking? 
In this case, the Automatic defrosting operation is working. The in-
door unit stops for maximum of 15 minutes. (Refer to 

page 7

.)

<In the Dry mode> The indoor unit operates at low fan speed to
adjust the room humidity, and may stop from time to time.

<In the Auto mode> While the monitoring operation, the fan
rotates at very low speed.

Noise is heard.

Is the unit operating, or immediate after stopping operation?
In this case, refrigerant fl owing sound may be heard. It may be
particularly noticeable for 2-3 minutes after starting operation.

Do you hear a slight squeaking sound during the operation?
This sound is produced by the minute expansion and contraction
of the front panel caused by temperature change.

<In the Heating mode> Do you hear a sizzling sound?
This sound is produced by the Automatic defrosting operation.
(Refer to 

page 7

.)

Smell coming from the unit.

The air conditioner may absorb various smells generated from
interior textile, furniture, or cigarette smoke. These smells may be
emitted during the operation.

Mist or steam is emitted from the unit.

<In the Cooling or Dry mode> A thin mist may be generated by
condensation formed with sudden cooling process.

<In the Heating mode> Is [  ] indicator on the indoor unit blinking? 
In this case, steam may rise from the outdoor unit because of the 
Automatic defrosting operation.(Refer to 

page 7

.)

Outdoor unit emits water.

<In the Heating mode> The outdoor unit may emit water gener-
ated by the Automatic defrosting operation. (Refer to 

page 7

.)

The unit operates diff erently from the remote controller setting.

Are the batteries in the remote controller exhausted?



Replace the batteries.

Operation is delayed after restart.

Has the power supply turned from Off  to On suddenly?
In this case,  the compressor will not operate for about 3 minutes
to prevent a blowout of the fuse.

Immediately stop operation and turn off  the electrical breaker in 

following cases. Then consult authorized service personnel.

• The problem persists even if you perform these checks or

diagnostics.

• On the indoor unit, [  ] and [   ] blink while [   ] is blinking fast.

NOTES: 

For any troubleshooting related to the W-LAN control, refer 
to the setting manual for W-LAN adapter or the mobile app 
installed in your smartphone or tablet PC.

State of indicator lamps

:  The instruction is relating to the wireless LAN control

(optional).

Lighting pattern: 

 Off ,     On,   

 Blinking,   

 Any state

State

Causes and solutions

See

page

Automatic defrosting operation

 Please wait until fi nishing the defrosting 

(maximum of 15 minutes).

7

Filter indicator



Clean the air fi lter and reset the fi lter 
sign.

6

Error code display



Consult authorized service personnel.

-

Timer setting error because of Auto restart



Reset the clock and timer settings.

7

Test run operation (for authorized 
personnel only)



Press

 

 

to quit the test run.

3

(Slow)

The power to the wireless router is 
not on.

-



Check that the power to the wireless 
router is on.

There is a possibility that the W-LAN 
adapter is not properly connected to 
the wireless router.

7



Disconnect the power supply to the air 
conditioner (via breaker or plug), and 
then re-connect.

The software of the W-LAN adapter 
is being updated.

-

During the air conditioner registration 
(pairing of W-LAN adapter)

8

Restricted function

-

 Manual Auto operation and Filter indicator

reset

You can operate the air conditioner with 

 on the 

indoor unit.

Status

Length of pressing down Mode or operation

In operation More than 3 seconds

Stop

Stopping

2 seconds or less

Filter indicator reset

More than 3 seconds and 

less than 10 seconds

Auto

More than 10 seconds

(Only for servicing.*)

Forced cooling

*:  To stop the forced cooling, press this button or

 

 

on the remote 

controller.

(3 times)

(Fast)

9333892009_OM.indb   9

9333892009_OM.indb   9

12/21/2018   2:34:05 PM

12/21/2018   2:34:05 PM

Summary of Contents for ASYG07-09-12KPCA

Page 1: ...rical breaker or disconnecting the power plug Then consult authorized service personnel Take care not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any...

Page 2: ...r entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any other electrical products or household belongings under this product Dripping condensa...

Page 3: ...se a tip of a ballpoint pen or other small object NOTES Use specified type of batteries only Do not mix different types or new and used batteries together Batteries can be used about 1 year in ordinary use If the remote control range noticeably shortens replace the batteries Remote controller display In this section all the possible indicators are displayed for description In actual operation the di...

Page 4: ... operation the indoor unit fan rotates at very low speed for 3 5 minutes the Automatic defrosting operation overrides the Heating operation when necessary In the Fan mode temperature control is not available 4 AIRFLOW SETTINGS 4 1 Fan speed setting Press to control the fan speed The fan speed changes as follows AUTO HIGH MED LOW QUIET When is selected the fan speed depends on the operating conditi...

Page 5: ...nditioner operation turns off 6 ENERGY SAVING OPERATIONS 6 1 Economy operation It saves more electricity than other operation modes by changing the set temperature to a moderate setting Press to activate deactivate the Economy operation indicator on the indoor unit will turn on Operation mode Room temperature Cooling Dry Few degrees higher than the set temperature Heating Few degrees lower than the...

Page 6: ... intake grille horizontal set the left and right mounting shafts into the pillow blocks at the top of the front panel Insert the shaft until it snaps to latch each shaft properly 2 Close the intake grille 3 Press 4 places on the intake grille to close it completely After extended non use of the unit If you have shut down the indoor unit for 1 month or more perform the Fan mode operation for half a...

Page 7: ...circuit working Depending on the operating conditions the heat exchanger may freeze causing water leakage or other malfunction in the Cooling or Dry mode Other information Do not use the air conditioner for any purpose other than room cooling dry room heating or fan For the permissible ranges of temperature and humidity for the outdoor unit refer to the outdoor unit installation manual 10 OPTIONAL...

Page 8: ...onditioner registration pairing of W LAN adapter to reconnect to a different wireless router NOTES Wireless LAN setup is not possible if the previous owner did not unregister or initialize this product In this case please contact your authorized service personnel 11 TROUBLESHOOTING WARNING In the following events immediately stop operation of the air conditioner and disconnect all the power supply ...

Page 9: ...ll not operate for about 3 minutes to prevent a blowout of the fuse Immediately stop operation and turn off the electrical breaker in following cases Then consult authorized service personnel The problem persists even if you perform these checks or diagnostics On the indoor unit and blink while is blinking fast NOTES For any troubleshooting related to the W LAN control refer to the setting manual f...