background image

En-10

OPERATING MANUAL

Care and Cleaning

 

CAUTION

• Before cleaning the indoor unit, be sure to turn it off and all the power supply has been disconnected. 

• Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an 

effect on the proper working or performance of the air conditioner.

• Do not touch the aluminum 

¿

 ns of heat exchanger built-in the indoor unit to avoid personal injury when you  maintain the unit.

• Do not expose the indoor unit to liquid insecticides or hair sprays.

• Do not stand on slippery, uneven or unstable surfaces when you maintain the unit.

Daily care

When cleaning the indoor unit body, mind the following:

• Do not use water hotter than 40 °C.
• Do not use scouring cleanser, volatile solvents such as benzene or 

thinner.

• Wipe the unit gently by using soft cloth.

 Cleaning the intake grille

1

  Open the intake grille in direction of the arrow 

a

. While gently 

pressing the left and right mounting shafts of the intake grille 
outward 

b

, remove the intake grille in direction of the arrow 

c

.

a

a

b

c

b

c

2

  Wash the intake grille gently with water or wipe it gently with a 

soft cloth moisten with warm water.

 

Then wipe it with a dry and soft cloth.

3

  While holding the grille horizontal, set the left and right mounting 

shafts into the pillow blocks at the top of the panel 

a

. To latch 

each shaft properly, insert the shaft until it snaps.

 

Then close the intake grille 

b

.

a

a

b

b

4

  Press 4 places on the intake grille to close it completely.

  Cleaning the air 

¿

 lters

Mind that you have a periodical cleaning of the air 

¿

 lters to prevent 

reducing the operation ef

¿

 ciency of the product. 

Using of clogged air 

¿

 lter with dust will lower the product performance, 

and may cause air

À

 ow reduction or increase of operating noise. 

Clean the air 

¿

 lters once every 2 weeks under normal use.

1

  Open the intake grille.

 (Refer 

to 

a

 of step 1 in “Cleaning the intake grille”.)

2

  While holding the intake grille with your hand, pull up the handle 

of the 

¿

 lter in direction of the arrow and release the 2 claws 

b

.

Then pull the 

¿

 lter out with gently sliding it downward 

c

.

a

b

b

a

c

3

  Filter holder and air cleaning 

¿

 lter are attached on the rear side 

of the air 

¿

 lter. Remove them from the air 

¿

 lter by unlatching each 

corner of the 

¿

 lter holder 

d

.

d

d

d

d

4

  Remove dust by using a vacuum cleaner or by washing the 

¿

 lter.

When you wash the 

¿

 lter, use neutral household detergent and 

warm water.
After rinse the 

¿

 lter well, dry it throughly in a shaded place before 

you reinstall it.

5

  Attach the air cleaning 

¿

 lter and the 

¿

 lter holder to each air 

¿

 lter.

6

  Attach the air 

¿

 lter with aligning both side of the 

¿

 lter with the front 

panel, and push in the 

¿

 lter fully.

Note:

 

Make sure that 2 claws are 

¿

 rmly snapped to the guide holes on 

the panel.

7

  Close the intake grille 

¿

 rmly.

(Refer to step 4 in “Cleaning the intake grille”.)

9333003023_OM_EN.indd   10

9333003023_OM_EN.indd   10

8/12/2013   8:53:50 AM

8/12/2013   8:53:50 AM

Summary of Contents for ASTG07CMCA

Page 1: ...be sure to keep away from re or any Àammables and consult authorized service personnel If you see lightning or hear thunder there might be a lightning strike To prevent electric shock hazard turn off the air conditioner by using the remote controller and do not touch the unit or the power plug during thunderstorm The appliance shall be stored in a room without continuously operating ignition sourc...

Page 2: ...nt of refrigerant leakage be sure to keep away from re or any Àammables and consult authorized service personnel If you see lightning or hear thunder there might be a lightning strike To prevent electric shock hazard turn off the air conditioner by using the remote controller and do not touch the unit or the power plug during thunderstorm The appliance shall be stored in a room without continuousl...

Page 3: ...tems Do not expose animals or plants to the direct airÀow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum ns of heat exchanger built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not direct the airÀow at replaces or heating apparatus Do not block or cover the int...

Page 4: ...RY mode may cause condensation to form and the drops may damage your property 6 Power diffuser In conjunction with movement of the vertical airÀow direction louver the angle of the power diffuser moves as follows Vertical airÀow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 7 Drain hose 8 Remote controller signal receiver CAUTION For appropri...

Page 5: ...th the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airÀow to quickly cool down the room When activated the indoor unit will emit 3 short beeps To turn off press the POWERFUL button again The indoor unit will then emit 2 short beeps POWERFUL operation is automatically t...

Page 6: ... asleep comfortably with gradual temperature control See page 6 13 ON OFF timer button Activates the ON OFF timer 14 NEXT button Used for adjusting the timer setting 15 BACK button Used for adjusting the timer setting 16 RESET button When you press the RESET button press it gently by using the tip of a ballpoint pen or other small object in correct direction as shown in this gure RESET See page 2 ...

Page 7: ...EEP indicator is on Erases the indicator To help you to fall asleep comfortably and prevent excessive cooling in sleep the SLEEP timer controls the temperature setting automatically in accordance with the set time shown as follows The air conditioner completely turns off after the set time has elapsed Set temperature Set time 1 hour 2 C 1 C In COOL or DRY mode WEEKLY timer ON and OFF timer can be ...

Page 8: ...e SELECT button to set the temperature If you want to move on to the next setting press the NEXT button return to step 4 and con gure the next setting 8 To complete the setting press the SEND button If you want to cancel the setting midway please press the TIMER SETTING button instead of pressing the SEND button Notes Ɣ When canceling the WEEKLY timer select No Timer Operation in Step 5 in the WEE...

Page 9: ...LEEP timer will be prioritized This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switches over to the appropriate operat...

Page 10: ...he malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller Temperature and Humidity Range Permissible ranges of temperature and humidity are as follows COOL DRY Indoor temperature About 18 C to 32 C Indoor humidity Below approximately 80 If the air conditioner is used continuo...

Page 11: ...shaft properly insert the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air lters Mind that you have a periodical cleaning of the air lters to prevent reducing the operation ef ciency of the product Using of clogged air lter with dust will lower the product performance and may cause airÀow reduction or increase...

Page 12: ...once every 3 months under normal use By setting the fan speed high the air cleaning effect increases Ion deodorization lter UTR FA16 2 Light blue 1 sheet The lter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra ne particle ceramic To maintain the deodorizing effect clean the lter once every 3 months as follows 1 Remove the...

Page 13: ...ow speed and the airÀow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Before you call for or request servicing troubleshoot a problem by performing following checks Symptom Diagnostic See page Does not operate at all Has the circuit breaker been turned o...

Page 14: ...deterioration of those items Do not e pose animals or plants to the direct airÀow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum ns of heat e changer built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not direct the airÀow at replaces or heating apparatus Do no...

Page 15: ...on 4 7 during COOL or DRY mode may cause condensation to form and the drops may damage your property 6 Power diffuser In conjunction with movement of the vertical airÀow direction louver the angle of the power diffuser moves as follows Vertical airÀow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 7 Drain hose 8 Remote controller signal receiv...

Page 16: ...e display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at ma imum power and strong airÀow to quickly cool down the room When activated the indoor unit will emit 3 short beeps To turn off press the POWERFUL button again The indoor unit will then emit 2 short beeps POWERFUL operat...

Page 17: ... that helps you to fall asleep comfortably with gradual temperature control See page 6 13 ON OFF timer button Activates the ON OFF timer 14 NEXT button Used for adjusting the timer setting 15 BACK button Used for adjusting the timer setting 16 RESET button When you press the RESET button press it gently by using the tip of a ballpoint pen or other small object in correct direction as shown in this...

Page 18: ...SLEEP button while the SLEEP indicator is on Erases the indicator To help you to fall asleep comfortably and prevent e cessive cooling in sleep the SLEEP timer controls the temperature setting automatically in accordance with the set time shown as follows The air conditioner completely turns off after the set time has elapsed Set temperature Set time 1 hour 2 C 1 C In COOL or DRY mode WEEKLY timer...

Page 19: ...NEXT button 7 Press the SELECT button to set the temperature If you want to move on to the ne t setting press the NEXT button return to step 4 and con gure the ne t setting 8 To complete the setting press the SEND button If you want to cancel the setting midway please press the TIMER SETTING button instead of pressing the SEND button Notes Ɣ When canceling the WEEKLY timer select No Timer Operatio...

Page 20: ...LEEP timer page 6 the SLEEP timer will be prioritized This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switches over to...

Page 21: ...transmitter may cause the malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller Temperature and Humidity Range Permissible ranges of temperature and humidity are as follows COOL DRY Indoor temperature About 1 C to 32 C Indoor humidity Below appro imately 0 If the air conditi...

Page 22: ... panel a To latch each shaft properly insert the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air lters Mind that you have a periodical cleaning of the air lters to prevent reducing the operation ef ciency of the product Using of clogged air lter with dust will lower the product performance and may cause airÀo...

Page 23: ...pened Replace the lter once every 3 months under normal use By setting the fan speed high the air cleaning effect increases Ion deodorization lter UTR FA16 2 Light blue 1 sheet The lter deodorizes by powerfully decomposing absorbed odors using the o idizing and reducing effects of ions generated by the ultra ne particle ceramic To maintain the deodorizing effect clean the lter once every 3 months ...

Page 24: ...he fan rotates at very low speed and the airÀow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Before you call for or request servicing troubleshoot a problem by performing following checks Symptom Diagnostic See page Does not operate at all Has the circu...