background image

PART NO. 9373384236

English

OPERATING MANUAL

INDOOR UNIT (Outdoor air unit)

Keep this manual for future reference

Deutsch

BEDIENUNGSANLEITUNG

INNENGERÄT (Außenluftgerät)

Bewahren Sie dieses Handbuch für eine spätere Bezugnahme auf.

Français

Español

MODE D’EMPLOI

MANUAL DE FUNCIONAMIENTO

UNITÉ INTÉRIEURE (Unité d’air extérieure)

UNIDAD INTERIOR (Unidad de aire exterior)

Conservez ce manuel pour pour toute référence ultérieure.

Conserve este manual para posibles consultas futuras.

Italiano

MANUALE DI ISTRUZIONI

UNITÀ INTERNA (Unità esterna aria)

Conservare questo manuale per consultazione futura.

Ελληνικ

ά

Português

ΕΓΧΕΙΡΙΔΙΟ

 

ΛΕΙΤΟΥΡΓΙΑΣ

ΕΣΩΤΕΡΙΚΗ

 

ΜΟΝΑΔΑ

 (

Εξωτερική

 

μονάδα

 

αέρα

)

Διατηρήστε

 

το

 

παρόν

 

εγχειρίδιο

 

για

 

μελλοντική

 

αναφορά

.

MANUAL DE FUNCIONAMENTO

UNIDADE INTERIOR (Unidade exterior de ar)

Guarde este manual para consulta futura.

Ру

сский

Türkçe

РУКОВОДСТВО

 

ПО

 

ЭКСПЛУАТАЦИИ

ВНУТРЕННИЙ

 

МОДУЛЬ

 (

Внешний

 

воздушный

 

модуль

)

Сохраните

 

данное

 

руководство

 

для

 

последующего

 

использования

.

KULLANIM KILAVUZU

İ

Ç ÜN

İ

TE (D

ı

ş

 hava ünitesi)

Bu k

ı

lavuzu ileride ba

ş

vurmak üzere saklay

ı

n.

ARXH054GTAH

ARXH072GTAH

ARXH096GTAH

[Original instructions]

Refer to the rating label with the serial number.

MADE IN THAILAND

9373384236-01_OM_9L.indb   cover1

9373384236-01_OM_9L.indb   cover1

2015/11/13   13:56:36

2015/11/13   13:56:36

Summary of Contents for ARXH054GTAH

Page 1: ...are questo manuale per consultazione futura Ελληνικά Português ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Εξωτερική μονάδα αέρα Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά MANUAL DE FUNCIONAMENTO UNIDADE INTERIOR Unidade exterior de ar Guarde este manual para consulta futura Русский Türkçe РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ Внешний воздушный модуль Сохраните данное руководство дл...

Page 2: ...o not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Check the condition of the installation stand for damage Operate only with air filters installed Do not drink the water drained from the air conditioner Do not apply any heavy pressure to radiator fins Do not use inflammable gases near the air conditioner Do not touch the piping during operation En...

Page 3: ...t result ing in reduced operating performance In order to prevent this kind of reduced performance this unit is equipped with a Microcomputer con trolled automatic defrosting function If frost forms the air conditioner will temporarily stop and the defrosting circuit will operate briefly for about 4 to 15 minutes During Automatic Defrosting operation the OPERATION indicator lamp green will flash l...

Page 4: ...ly This sound is produced by the Automatic Defrosting operation See page 2 Smells Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner Fog comes out of the indoor unit During Cooling operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by...

Page 5: ...URRENT A 1 12 1 73 2 23 AIRFLOW RATE m3 h 1 080 1 680 2 100 SOUND PRESSURE LEVEL dB A 42 44 47 DIMENSIONS WEIGHT HEIGHT mm 425 450 WIDTH mm 1 367 1 583 DEPTH mm 572 700 WEIGHT kg 48 55 71 Acoustic Noise Information The maximum sound pressure level is less than 70 dB A for both indoor unit and outdoor unit According to IEC 704 1 and ISO 3744 Standard static pressure ARXH054 185 Pa ARXH072 200 Pa AR...

Page 6: ...9373384236 01_OM_9L indb 6 9373384236 01_OM_9L indb 6 2015 11 13 13 56 39 2015 11 13 13 56 39 ...