Fujitsu ARXH054GTAH Operating Manual Download Page 5

En-4

SPECIFICATIONS

MODEL

ARXH054

GTAH

ARXH072

GTAH

ARXH096

GTAH

POWER SOURCE

230 V~50/60 Hz

AVAILABLE VOLT-
AGE RANGE

198 to 264 V (50Hz) 
198 to 253 V (60Hz)

COOLING 
CAPACITY

[kW]

14.0 22.4 28.0

[Btu/h]

47,800

76,400

95,500

HEATING 
CAPACITY

[kW]

8.9

13.9

17.4 

[Btu/h]

30,400

47,400

59,400

INPUT 
POWER

[W]

179

292 370

CURRENT

[A]

1.12

1.73

2.23

AIRFLOW 
RATE

[m

3

/h]

1,080 1,680 2,100

SOUND 
PRESSURE 
LEVEL

dB [A]

42

44

47 

DIMENSIONS & WEIGHT

HEIGHT

[mm]

425

450

WIDTH

[mm]

1,367

1,583

DEPTH

[mm]

572

700

WEIGHT

[kg]

48

55

71

 

Acoustic Noise Information : 
The maximum sound pressure level is less than 70 dB (A) for both 
indoor unit and outdoor unit. According to IEC 704-1 and ISO 3744.

 

Standard static pressure : 
ARXH054: 185 Pa, ARXH072: 200 Pa, ARXH096: 200 Pa 

9373384236-01_OM_9L.indb   4

9373384236-01_OM_9L.indb   4

2015/11/13   13:56:37

2015/11/13   13:56:37

Summary of Contents for ARXH054GTAH

Page 1: ...are questo manuale per consultazione futura Ελληνικά Português ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Εξωτερική μονάδα αέρα Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά MANUAL DE FUNCIONAMENTO UNIDADE INTERIOR Unidade exterior de ar Guarde este manual para consulta futura Русский Türkçe РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ Внешний воздушный модуль Сохраните данное руководство дл...

Page 2: ...o not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Check the condition of the installation stand for damage Operate only with air filters installed Do not drink the water drained from the air conditioner Do not apply any heavy pressure to radiator fins Do not use inflammable gases near the air conditioner Do not touch the piping during operation En...

Page 3: ...t result ing in reduced operating performance In order to prevent this kind of reduced performance this unit is equipped with a Microcomputer con trolled automatic defrosting function If frost forms the air conditioner will temporarily stop and the defrosting circuit will operate briefly for about 4 to 15 minutes During Automatic Defrosting operation the OPERATION indicator lamp green will flash l...

Page 4: ...ly This sound is produced by the Automatic Defrosting operation See page 2 Smells Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner Fog comes out of the indoor unit During Cooling operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by...

Page 5: ...URRENT A 1 12 1 73 2 23 AIRFLOW RATE m3 h 1 080 1 680 2 100 SOUND PRESSURE LEVEL dB A 42 44 47 DIMENSIONS WEIGHT HEIGHT mm 425 450 WIDTH mm 1 367 1 583 DEPTH mm 572 700 WEIGHT kg 48 55 71 Acoustic Noise Information The maximum sound pressure level is less than 70 dB A for both indoor unit and outdoor unit According to IEC 704 1 and ISO 3744 Standard static pressure ARXH054 185 Pa ARXH072 200 Pa AR...

Page 6: ...9373384236 01_OM_9L indb 6 9373384236 01_OM_9L indb 6 2015 11 13 13 56 39 2015 11 13 13 56 39 ...

Reviews: