En-17
Function details
Function
Function
number
Setting
number
Default
Details
Filter
indicator
interval
11
00
Default
○
Adjust the
fi
lter cleaning
interval noti
fi
cation. If the noti-
fi
cation is too early, change to
setting 01. If the noti
fi
cation is
too late, change to setting 02.
01
Longer
02
Shorter
Filter
indicator
action
13
00
Enable
○
Enable or disable the
fi
lter
indicator. Setting 02 is for use
with a central remote control.
01
Disable
02
Display
only on
central
remote
control
Cool air
tem-
perature
trigger
30
00
Default
○
Adjust the cool air trigger tem-
perature. To lower the trigger
temperature, use setting 01.
To raise the trigger tempera-
ture, use setting 02.
01 Adjust (1)
02 Adjust (2)
Hot air
tem-
perature
trigger
31
00
Default
○
Adjust the hot air trigger
temperature. To lower the trig-
ger temperature by 6 degrees
C, use setting 01. To lower
the trigger temperature by 4
degrees C, use setting 02. To
raise the trigger temperature,
use setting 03.
01 Adjust (1)
02 Adjust (2)
03 Adjust (3)
Auto
restart
40
00
Enable
Enable or disable automatic
system restart after a power
outage.
01
Disable
○
External
control
46
00 Start/Stop
○
Allow an external controller
to start or stop the system,
or to perform an emergency
shutdown.
* If an emergency shutdown is
performed from an external
controller, all refrigerant
systems will be disabled.
01
Emergency
stop
Error
report
target
47
00
All
○
Change the target for report-
ing errors. Errors can either
be reported in all locations, or
only on the wired remote.
01
Display
only on
central
remote
control
8. TEST OPERATION
8.1. Test operation using PCB (Outdoor
unit)
• Refer to the Installation Manual for the outdoor unit if
the PCB for the outdoor unit is to be used for the test
operation.
8.2. Test operation using Remote Controller
• Refer to the Installation Manual for the remote control unit
to perform the test operation using the wireless remote
control unit.
• When the air conditioner is being test run, the OPERATION
and TIMER indicators
fl
ash slowly at the same time.
9. CHECK LIST
Pay special attention to the check items below when
installing the indoor unit(s). After installation is complete, be
sure to check the following check items again.
CHECK ITEMS
If not performed
correctly
CHECK
BOX
Has the indoor unit been
installed correctly?
Vibration, noise,
indoor unit may drop
Has there been a check
for gas leaks (refrigerant
pipes)?
No cooling, No heating
Has heat insulation work
been completed?
Water leakage
Does water drain easily
from the indoor units?
Water leakage
Is the voltage of the
power source the same
as that indicated on the
label on the indoor unit?
No operation, heat or
burn damage
Are the wires and pipes
all connected completely?
No operation, heat or
burn damage
Is the indoor unit
grounded?
Short circuit
Is the connection cable
the specified thickness?
No operation, heat or
burn damage
Are the inlets and outlets
free of any obstacles?
No cooling, No heating
After installation is
completed, has the proper
operation and handling
been explained to the
user?