 CAUTION

• Before cleaning this product, be sure to turn it off and disconnect all the power supply. 
• Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an 

effect on the proper working or performance of the air conditioner.

• Do not touch the aluminum 

fi

 ns of heat exchanger built-in the indoor unit to avoid personal injury when you  maintain the unit.

• Do not expose the indoor unit to liquid insecticides or hair sprays.
• Do not stand on slippery, uneven or unstable surfaces when you maintain the unit.

Daily care

When cleaning the indoor unit body, mind the following:

• Do not use water hotter than 40 °C.
• Do not use scouring cleanser, volatile solvents such as benzene or 

thinner.

• Wipe the unit gently by using soft cloth.

 Cleaning the intake grille

1

  Open the intake grille in direction of the arrow 

a

. While gently 

pressing the left and right mounting shafts of the intake grille 
outward 

b

, remove the intake grille in direction of the arrow 

c

.

a

a

b

c

c

b

2

  Wash the intake grille gently with water or wipe it gently with a 

soft cloth moisten with warm water.

 

Then wipe it with a dry and soft cloth.

3

  While holding the grille horizontal, set the left and right mounting 

shafts into the pillow blocks at the top of the panel 

a

. To latch 

each shaft properly, insert the shaft until it snaps.

 

Then close the intake grille 

b

.

b

b

a

a

4

  Press 4 places on the intake grille to close it completely.

Care and Cleaning

  Cleaning the air 

fi

 lters

Mind that you have a periodical cleaning of the air 

fi

 lters to prevent 

reducing the operation ef

fi

 ciency of the product. 

Using of clogged air 

fi

 lter with dust will lower the product performance, 

and may cause air

fl

 ow reduction or increase of operating noise. 

Clean the air 

fi

 lters once every 2 weeks under normal use.

1

  Pull up the handle 

a

 of the 

fi

 lter in direction of the arrow and 

release the 2 claws 

b

.

 

Then pull the 

fi

 lter out with gently sliding it downward 

c

.

a

a

c

b

b

2

  Remove dust by using a vacuum cleaner or by washing the 

fi

 lter.

 

When you wash the 

fi

 lter, use neutral household detergent and 

warm water.

 

After rinse the 

fi

 lter well, dry it thoroughly in a shaded place 

before you reinstall it.

3

  Attach the air 

fi

 lter with aligning both side of the 

fi

 lter with the 

panel, and push in the 

fi

 lter fully.

Note:

 

Make sure that 2 claws are 

fi

 rmly snapped to the guide holes on 

the panel.

After extended non-use of the unit

If you have shut down the indoor unit for 1 month or more, perform the 
FAN operation for half a day to dry the internal parts thoroughly before 
you perform normal operation.

Additional inspection

After long period of use, accumulated dust inside the indoor unit may 
reduce the product performance even if you have maintained the unit 
with instructed daily care or cleaning procedures written in this manual.
In such a case, the product inspection is recommended.
For more information, consult authorized service personnel.

9332621006-04_OM.indb   5

9332621006-04_OM.indb   5

2016/3/29   11:41:24

2016/3/29   11:41:24

Summary of Contents for AOYG09LLCE

Page 1: ...y with the appliance Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use flammable gases near this product Do not expose yourself directly to the cooling airflow for many hours Do not insert your fingers or any other objects into outlet port open panel or intake grille Do not operate with wet hands CAU...

Page 2: ...TION For appropriate signal transmission between remote controller and the indoor unit keep the signal receiver away from following items Direct sunlight or other strong light Flat panel television screen In rooms with instantaneous fluorescent lights such as in verter type ones the signal may not be transmitted properly In such a case consult the store that you purchased the product 7 ECONOMY ind...

Page 3: ...tting range AUTO 18 30 C COOL DRY 18 30 C HEAT 16 30 C Temperature control is not available in FAN mode 4 FAN button Controls the fan speed AUTO HIGH MED LOW QUIET When AUTO is selected the fan speed is automatically adjusted according to the operation mode 5 SET button Adjusts the vertical airflow direction 6 SWING button Starts or stops automatic swing of the vertical airflow direction louver Ea...

Page 4: ...ables quick cooling down or warming up of the room When you press the button to start the POWERFUL operation the indoor unit emits 3 short beeps POWERFUL operation is automatically turned off in the following situations Adjusted room temperature reached to the defined temperature in temperature setting in COOL DRY or HEAT mode 20 minutes have passed after finishing the POWERFUL operation mode sett...

Page 5: ...le b b b a a 4 Press 4 places on the intake grille to close it completely Care and Cleaning Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating noise Clean the air filters once ...

Page 6: ... unit In HEAT mode the outdoor unit stops and the indoor unit operates at very low fan speed if the room temperature rises above the set temperature In HEAT mode the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing 4 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and ma...