6) Indoor unit fan control for energy saving for cooling
Enables or disables the power-saving function by controlling the indoor unit fan rotation when the
outdoor unit is stopped during cooling operation.
Function number
Setting value
Setting description
Factory setting
49
00
Disable
01
Enable
02
Remote controller
♦
00: When the outdoor unit is stopped, the indoor unit fan operates continuously following the setting
on the remote controller.
01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very low speed.
02: Enable or disable this function by remote controller setting.
NOTES:
• As the factory setting, this setting is initially activated.
• Set to "00" or "01" when connecting a remote controller that cannot set the Fan control for ener-
gy saving function or connecting a network converter.
To confirm if the remote controller has this setting, refer to the operating manual of each remote
controller.
7) Dual fan airflow (in COOL, DRY, and FAN modes)
Switches the dual fan vertical airflow in COOL, DRY, and FAN modes. (Set this when the dual fan
airflow is too strong or week.)
Function number
Setting value
Setting description
Factory setting
92
00
Standard
♦
01
Down
02
Up
8) Dual fan vertical airflow angle (in COOL, DRY, and FAN modes)
Switches the dual fan vertical airflow angle in COOL, DRY, and FAN modes. (Set this when the dual
fan airflow hits furniture or does not reach the intended area.)
Function number
Setting value
Setting description
Factory setting
93
00
Standard (70°)
♦
01
0°
02
30°
03
40°
04
45°
05
50°
06
60°
9) Maintenance indicator switchover
Display/hide the indicator that shows when to clean the dust box or the plasma air clean unit.
Function number
Setting value
Setting description
Factory setting
97
00
Enable
♦
01
Disable
- 23 -
10-1. Function settings by using remote controller
10. Function settings
WALL MOUNTED
ASYG09, 12KXCA
WALL MOUNTED
ASYG09, 12KXCA