5-2. Heating capacity
NOTE:
Values mentioned in the table are calculated based on the maximum capacity.
¢
Model: ASYG09KXCA
AFR
m
3
/h
810
Indoor temperature
16
18
20
22
24
Outdoor temperature
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15
-16
5.15
2.83
5.07
2.83
4.82
2.67
4.44
2.41
3.89
2.21
-10
-11
5.91
2.83
5.81
2.83
5.53
2.75
5.09
2.48
4.46
2.28
-5
-7
6.55
2.83
6.44
2.83
6.13
2.83
5.64
2.56
4.94
2.35
0
-2
7.07
2.83
6.95
2.26
6.61
2.05
6.09
1.85
5.33
1.70
5
3
7.46
2.28
7.34
2.05
6.98
1.86
6.43
1.68
5.63
1.54
7
6
7.59
2.19
7.46
1.97
7.10
1.78
6.54
1.61
5.72
1.48
10
8
7.32
2.06
7.20
1.85
6.85
1.68
6.30
1.52
5.52
1.39
15
10
7.03
1.85
6.92
1.66
6.58
1.50
6.06
1.36
5.30
1.25
20
15
6.94
1.65
6.82
1.49
6.49
1.35
5.97
1.22
5.23
1.12
24
18
7.01
1.50
6.90
1.35
6.56
1.22
6.04
1.10
5.29
1.01
¢
Model: ASYG12KXCA
AFR
m
3
/h
810
Indoor temperature
16
18
20
22
24
Outdoor temperature
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15
-16
6.40
3.26
6.40
3.39
6.11
3.08
5.61
2.76
4.86
2.55
-10
-11
6.62
3.26
7.33
3.26
7.01
3.17
6.44
2.85
5.58
2.63
-5
-7
6.68
3.26
7.40
3.26
7.77
3.26
7.13
2.93
6.19
2.71
0
-2
8.85
3.26
8.78
3.09
8.38
2.81
7.70
2.52
6.67
2.33
5
3
9.34
2.98
9.27
2.68
8.85
2.43
8.13
2.18
7.05
2.02
7
6
9.49
2.77
9.42
2.49
9.00
2.26
8.26
2.03
7.16
1.87
10
8
9.16
2.59
9.09
2.32
8.68
2.11
7.97
1.90
6.91
1.75
15
10
8.80
2.34
8.73
2.10
8.34
1.91
7.66
1.71
6.64
1.58
20
15
8.68
2.03
8.62
1.82
8.23
1.65
7.56
1.49
6.55
1.37
24
18
8.77
1.90
8.71
1.70
8.32
1.55
7.63
1.39
6.62
1.28
- 11 -
5-2. Heating capacity
5. Capacity table
WALL MOUNTED
ASYG09, 12KXCA
WALL MOUNTED