01-07
Airflow can be switched in 5 steps such as Auto, Quiet, Lo, Me, Hi,
while indoor unit fan only runs.
When fan mode is set at (Auto), it operates on (Me) fan speed.
2. FAN OPERATION
3. COOLING OPERATION
Switch the airflow [Auto], and indoor fan motor will run
according to room temperature, as below.
On the other hand, if switched in [Hi] ~ [Quiet],
indoor motor will run at a constant airflow of [Cool]
operation modes Quiet, Lo, Me, Hi, as the previous page.
Fig : Airflow changeover (Cooling : Auto)
When room
temperature rises
When room
temperature drops
TR : Room temperature
Ts : Setting temperature
TR-Ts ≥ 2°C
1°C > TR-Ts
2°C > TR-Ts ≥ 1°C
TR-Ts ≥ 2.5°C
1.5°C > TR-Ts
2.5°C > TR-Ts ≥ 1.5°C
Hi mode
Me mode
Lo mode