4. INSTALLATION 

4.1. Outdoor unit installation

  Set the unit on a strong stand such as thing made of concrete blocks to minimize shock 

and vibration.

  Do not set the unit directly on the ground because it will cause trouble.

For 9,000 But/h model:

Switch cover A, B removal

(1) Remove the three tapping screws.
(2) Push downward the switch cover B.
(3) Push upward the switch cover A.

Installing the Switch cover A, B

(1)  After inserting the three hooks of switch cover A, 

then push upward, and then tighten the two tap-
ping screws.

(2)  After inserting the three hooks of switch cover B, 

then push upward, and then tighten the one tap-
ping screw.

For 12,000 Btu/h model and 14,000 Btu/h model:

Connector cover

Tapping screw

Hook

Tapping screw

Connector cover removal

• Remove the tapping screws.

Installing the connector cover

(1) After inserting the four hooks, then slide the cover.
(2) Tighten the tapping screws.

 WARNING

Install the unit where it will not be tilted by more than 5°.

When installing the outdoor unit where it may exposed to strong wind, fasten it securely.

4.2. Outdoor unit wiring

For 9,000 But/h model: 

(1)  Remove the switch cover A and B from the outdoor unit.
(2)  Remove the cable clamp and nylon clamp from the outdoor unit.
(3)  Bend the end of the cable as shown in the 

fi

 gure.

(4)  Connect the end of the connection cable fully into the terminal block.
(5)  Fasten the sheath with a cable clamp.
(6)  Fasten the sheath with a nylon clamp.
(7)  Install the switch cover A and B.

Cable clamp

Nylon clamp

For 12,000 Btu/h model and 14,000 Btu/h model: 

(1)  Remove the outdoor unit connector cover.
(2)  Bend the end of the cable as shown in the 

fi

 gure.

(3)  Connect the end of the connection cable fully into the terminal block.
(4)  Fasten the sheath with a cable clamp.
(5)  Install the connector cover.

Cable clamp

Connection cable

N

L

3

2

1

1 2 3 4

Outdoor unit terminal block

Indoor unit terminal block

Connection cable

Earth screw

Earth screw

Power supply cable

N

L

3

2

1

25mm

12mm

5mm

5mm 12mm

20mm

Cable clamp

Earth 

screw

20mm

12mm

5mm

5mm

12mm

20mm

Connection cable

Power supply cable

Connection cable wiring for 9,000 Btu/h model

Run the connection cable to the rear of the outdoor unit within the A range of the arrows 

shown in the figure.

(The Switch cover B becomes difficult to install.)

A

Connection and 

Power supply cable
Nylon clamp

Screw

HOLE

HOLE

Connection cable wiring for 12,000 Btu/h model and 14,000 Btu/h model

Run the connection cable to the rear of the outdoor unit within the A range of the arrows 

shown in the figure..

(The connector cover becomes difficult to install.)

A

10 cm

8 cm

Connection cable

Hole

 CAUTION

Match the terminal block numbers and connection cable colors with those of the indoor 
unit.
Erroneous wiring may cause burning of the electric parts.

Connect the connection cables 

fi

 rmly to the terminal block. Imperfect installation may 

cause a 

fi

 re.

Always fasten the outside covering of the connection cable with the cable clamp. (If the 
insulator is chafed, electric leakage may occur.)
Securely earth the power cable.
Do not use the earth screw for an external connector. Only use for interconnection 
between two units.

4.3. Connecting the piping

CONNECTION

(1)  Install the outdoor unit wall cap (supplied with the optional installation set or pro-

cured at the site) to the wall pipe.

Hook

Hooks

Hooks

Switch cover A

Switch cover B

9319205106_IM.indb   4

9319205106_IM.indb   4

9/6/2011   10:14:40 AM

9/6/2011   10:14:40 AM

Summary of Contents for AOYG-09LTC

Page 1: ...IKKÖ jaettu UTENDØRSENHET Delt utgave For authorized service personnel only Kun til autoriseret servicepersonale Vain valtuutetuille huoltohenkilöille Kun for autorisert servicepersonell Swedish INSTALLATIONSHANDBOK UTOMHUSENHET Split typ Endast för auktoriserad servicepersonal Polish INSTRUKCJA MONTAŻU URZĄDZENIE ZEWNĘTRZNE typu split Do użytku wyłącznie przez autoryzowany personel obsługi techni...

Page 2: ...s for using R410A refrigerant The basic installation work procedures are the same as conventional refrigerant R22 models However pay careful attention to the following points Since the working pressure is 1 6 times higher than that of conventional refrigerant R22 models some of the piping and installation and service tools are special See the table below Especially when replacing a conventional re...

Page 3: ...rts to fail or the unit to leak water Area filled with mineral oil or containing a large amount of splashed oil or steam It will deteriorate plastic parts causing the parts to fail or the unit to leak water Area that generates substances that adversely affect the equipment such as sulfuric gas chlorine gas acid or alkali It will cause the copper pipes and brazed joints to corrode which can cause r...

Page 4: ...r cover 2 Bend the end of the cable as shown in the figure 3 Connect the end of the connection cable fully into the terminal block 4 Fasten the sheath with a cable clamp 5 Install the connector cover Cable clamp Connection cable N L 3 2 1 1 2 3 4 Outdoor unit terminal block Indoor unit terminal block Connection cable Earth screw Earth screw Power supply cable N L 3 2 1 25mm 12mm 5mm 5mm 12mm 20mm ...

Page 5: ...lowly loosen the valve stem of the 3 way valve When the compound pressure gauge reading reaches 0 1 0 2 MPa retighten the valve stem and disconnect the charge hose from the 3 way valve charging port If the stem of the 3 way valve is opened fully before the charge hose is disconnect ed it may be difficult to disconnect the charge hose 10 Fully open the valve stems of the 2 way valve and 3 way valve...

Reviews: