background image

DISASSEMBLY  ILLUSTRATION

Models : ARY30FUAN

ARY30UUAN

20

73

146

764

75

74

72

325

324

160

Insulation

Insulation

Control Box

Insulation

2005.04.11

11

Summary of Contents for AOY30FNBWL

Page 1: ... ARY30FUAN ARY30UUAN AOY30FNBWL AOY30UNBWL CONTENTS SPECIFICATIONS 1 OUTLINE AND DIMENSIONS 2 CIRCUIT DIAGRAM 4 REFRIGERANT SYSTEM DIAGRAM 5 INDOOR PCB CIRCUIT DIAGRAM 7 OUTDOOR PCB CIRCUIT DIAGRAM 9 DISASSEMBLY ILLUSTRATION 11 PARTS LIST 20 ACCESSORIES 22 ERROR CONTENTS 10 ...

Page 2: ...QUENCY RUNNING A COOLING 14 0 14 0 CURRENT HEATING 12 4 INPUT WATTS kW COOLING 2 99 2 99 HEATING 2 63 E E R kW kW COOLING 2 81 2 81 HEATING 3 61 MOISTURE REMOVAL hr 3 0 AIR CIRCULATION m3 hr 1 400 ELECTRICAL DATA FAN MOTOR COMPRESSOR Hermetic type 2 poles Induced by condenser Rotary 5JS330DAE01 V 230 DISCRIMINATION MFA 30PTT INDOOR HI SPEED r p m 990 UNIT MED SPEED r p m 920 LO SPEED r p m 850 OUT...

Page 3: ...Unit mm DIMENSIONS INDOOR UNIT 2005 04 11 2 ...

Page 4: ...400 300 31 77 900 830 21 9 12 370 196 147 170 99 650 Air Flow 2005 04 11 3 Unit mm OUTDOOR UNIT ...

Page 5: ...RY30UUAN AOY30UNBWL THo THR THR THPI THPI THo THERMISTOR PIPE TEMP THERMISTOR ROOM TEMP THR THPI THERMISTOR PIPE TEMP THERMISTOR ROOM TEMP COMPRESSOR ACCUMULATOR STRAINER STRAINER THERMOSTAT DISCHARGE TEMP EVAPORATOR CONDENSER PRESSURE CHECK VALVE REFRIGERANT PIPE 15 88mm 5 8 REFRIGERANT PIPE 9 52mm 3 8 OUTDOOR UNIT INDOOR UNIT CHARGING VALVE CAPILLARY TUBE THD THR THPI THO THD THPO THERMOSTAT OUT...

Page 6: ...ERLOAD PROTECTOR COMPRESSOR CAPACITOR FAN MOTOR CAPACITOR OUTDOOR THERMOSTAT FAN MOTOR FUSE TO INDDR UNIT TO POWER SUPPLY RELAY WHITE WHITE WHITE BLACK BLACK BLACK WHITE BLACK PURPLE GRAY BLUE RED WHITE RED BROWN BROWN 1 N L 2 3 S R C L H 1 5 4 6 C 1 3 6 4 1 3 6 4 OUTDOOR UNIT INDOOR UNIT 2005 04 27 5 ...

Page 7: ...BLACK GRAY GRAY BLACK BLACK BLACK BLACK BLACK RED RED WHITE BLACK GRAY GRAY BLUE RED RED WHITE RED RED RED BROWN BROWN 1 N L 2 3 S R 1 5 4 6 C 1 3 6 4 1 3 6 4 4 3 2 1 7 5 3 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 1 3 2 1 1 3 2 1 2 1 2 1 2 1 2 1 3 1 2 1 2 1 2 1 2 1 3 3 5 1 OUTDOOR UNIT INDOOR UNIT THERMISTOR DISCHARGE TEMP SOLENOID COIL BELT HEATER TRANSFORMER THERMISTOR OUTDOOR TEMP THERMISTOR PIPE TEMP...

Page 8: ...0 2 K104 G5N 1A K102 G5SB 14 DC12V K103 G5SB 14 DC12V K101 G5SB 14 DC12V K108 G5N 1A CR104 120 0 2 CN111 B2P3 VH B WHITE 1 2 CN101 B2P3 VH B C BLACK AC I N MAGNETIC RELAY N L FH101 FH102 F101 3 15A BET VA101 470V K110 G2R 1A DC12V 14V K108 K103 K101 K110 K102 1 9 3 7 6 5 4 8 2 10 UL1430 AWG26 GRAY UL1430 AWG26 GRAY UL1430 AWG26 GRAY UL1430 AWG26 GRAY UL1430 AWG26 GRAY UL1430 AWG26 GRAY UL1430 AWG2...

Page 9: ... C112 0 1 F C111 10 25V I C101 NJM7805 I C102 NJM7812 PRIMARY SECONDARY D101 D2SB20 2 3 1 4 2 1 JM103 UL1430 AWG22 RED UL1430 AWG22 RED R102 10K 1 4W C107 1000 50V R103 1 0K 1 2W C108 10 25V 14V Q101 2SC1932 C109 10 25V D102 MTZJ15C CN114 B3B XH AM WHITE 5V 12V 14V CN105 B04B PASK 1 WHITE CN104 B2B XARK 1 A RED CN103 B2P3 VH B R RED 2 1 UL1015 AWG22 VIOLET UL1015 AWG22 VIOLET POWER TRANSFORMER EZ ...

Page 10: ...POWER SOURCE 230V 50Hz POWER RELAY EL12D1 F M 3 5 uF 450V CONTROLLER PCB ASSEMBLY MAIN PCB EZ 0028HUE C Model AOY30UNBWL OUTDOOR PCB CIRCUIT DIAGRAM 2005 04 11 9 ...

Page 11: ...al 02 03 04 05 06 07 08 09 0A 0b 0c 0d 0E 0F 11 12 13 14 Error code Error contents Communication error indoor unit remote controller Communication error indoor unit outdoor unit 00 01 ERROR CONTENTS When a malfunction occurs in the outdoor unit the LEDs on the circuit board light to indicate the error Refer to the following table for the de scription of each error according to the LEDs When the fa...

Page 12: ...DISASSEMBLY ILLUSTRATION Models ARY30FUAN ARY30UUAN 20 73 146 764 75 74 72 325 324 160 Insulation Insulation Control Box Insulation 2005 04 11 11 ...

Page 13: ...111 56 108 110 41 150 40 67 139 138 164 2005 04 11 12 ...

Page 14: ...816 817 287 236 553 956 223 288 287 875 2005 04 11 13 ...

Page 15: ...1 34 2 3 4 5 35 6 7 Models AOY30FNBWL AOY30UNBWL 2005 04 11 14 ...

Page 16: ...13 36 12 11 10 9 8 14 13 Models AOY30FNBWL AOY30UNBWL 2005 04 11 15 ...

Page 17: ...23 38 24 39 16 15 21 37 18 17 22 37 Model AOY30FNBWL 2005 04 11 16 ...

Page 18: ...22 37 37 23 38 40 20 18 19 32 41 42 21 15 16 24 17 39 Model AOY30UNBWL 2005 04 11 17 ...

Page 19: ...27 29 26 33 31 28 Model AOY30FNBWL 2005 04 11 18 ...

Page 20: ...29 46 43 44 45 Model AOY30UNBWL 27 26 25 31 30 28 2005 04 11 19 ...

Page 21: ...sy 9374511013 325 Intake Frame Assy 9374216017 553 Transformer Power 9704129017 764 Drain Cap 9356541007 816 Terminal 3P 9703345012 817 Terminal 3P 9306489045 875 Power PCB Assy 9705668010 956 Control Cover B 9374222018 Thermo Spring A 313728262708 Thermistor Assy Room 9703299025 Thermistor Assy Pipe 9703297021 Remotecontroller Assy 9372266014 RFM Motor Band 9374646012 Motor Band B 9374648023 Cont...

Page 22: ...der Rubber 313728262708 Thermo Spring A 9900200015 Relay on PCB 9900037048 Thermistor Out Temp 9900043049 Heat Exchanger Thermistor 9361140257 Belt Heater 313728251908 4 Way Valve Rubber 9300301015 Special Nut M5 compressor 9372246054 Discharge B Assy 9374469017 Inlet Pipe Condenser C Assy 9374266050 Outlet Pipe Condenser A Assy 9373461067 Inlet Pipe Condenser A Assy 9900038038 Thermistor Discharg...

Page 23: ...313005446653 313005446759 9350716029 9352766015 312300787605 313361275805 31361275805 9372266014 0700181108 313806217708 9372714010 9372714010 INDOOR UNIT ACCESSORIES STANDARD ACCESSORIES Remote controller cord Part No 2005 04 11 22 OUTDOOR UNIT ACCESSORIES OPTIONAL PARTS Name and Shape Q ty Application For outdoor unit drain piping work May not be supplied depending on the model For filling in a ...

Page 24: ...0502G2755 ...

Reviews: