ERROR DISPLAY
operation
timer
Error contents
Error contents
thermistor
0.5 second
2 times
room temp. thermistor error
0.5 second
2 times
heat exchanger thermistor error
0.5 second
3 times
control unit
0.5 second
4 times
MANUAL AUTO button error
(indoor unit )
0.5 second
2 times
power source Hz decision error
0.5 second
4 times
fan motor
0.5 second
6 times
0.1 second
0.1 second
0.1 second
0.1 second
Indication :
When an error happens, first indication is "Large division indication".
Indication is switched by pushing TEST OPERATION button between "Large" and "Small".
0.1 second
0.1 second
0.1 second
0.1 second
0.1 second
0.1 second
0.1 second
lock error
(indoor unit)
0.5 second
2 times
r.p.m. error
model distinction error
0.5 seond
3 times
LED flashing
operation
timer
LED flashing
Small division indication