9

To Cancel the Timer:

Use the TIMER MODE button to select 
“CANCEL”.
The air conditioner will return to normal 
operation.

To Stop the Air Conditioner During 
Timer Operation:

Press the START/STOP button.

SLEEP TIMER OPERATION

Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped.

To Use the SLEEP Timer

While the air conditioner is operating or stopped, press the 
SLEEP button (Fig. 6 

J

).

The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 

5

) lights and the TIMER 

Indicator Lamp (green) (Fig. 3 

6

) light.

To Change the Timer Settings

Press the SLEEP button (Fig. 6 

J

) once again and set the time 

using the TIMER SET ( 

 / 

 ) buttons (Fig. 6 

O

).

Set the time while the Timer Mode Display is 

fl

 ashing (the 

fl

 ashing will continue about 

fi

 ve seconds).

 button: 

Press to advance the time.

 button: 

Press to reverse the time.

About 

fi

 ve seconds later, the entire display will reappear.

About the SLEEP Timer

To prevent excessive cooling during sleep, the SLEEP timer function automatically modi

fi

 es the temperature setting in accordance with 

the set time setting. When the set time has elapsed, the air conditioner completely stops.

During Cooling/Dry operation:

When the SLEEP timer is set, the temperature setting is automatically raised 1 °C every sixty minutes. When the temperature has been 
raised a total of 2 °C, the temperature setting at that time is maintained until the set time has elapsed, at which time the air conditioner 
automatically turns off.

 

SLEEP timer setting

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the Remote Controller is lost or otherwise unavailable.

How To Use the Main Unit Controls

Press the MANUAL AUTO button  (Fig. 2 

2

) on the main unit 

control panel.

To stop operation, press the MANUAL AUTO button (Fig. 2 

2

) once again. 

(Controls are located inside the intake grille)

  When the air conditioner is operated with 

the controls on the Main Unit, it will oper-
ate under the same mode as the AUTO 
mode selected on the Remote Controller 
(see page 7).

  The fan speed selected will be “AUTO” 

and the temperature setting will be stand-
ard.(24

°C

)

Set time

1 hour

1 ˚C

2 ˚C

9315345462_OM.indb   9

9315345462_OM.indb   9

6/23/2011   9:06:01 AM

6/23/2011   9:06:01 AM

Summary of Contents for AOTR24JFCB

Page 1: ...L MODEL ROOM AIR CONDITIONER WALL MOUNTED TYPE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this product ...

Page 2: ...ble Turn off power supply when not using the indoor unit for extended periods Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the airflow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to ...

Page 3: ...mode REMOVABLE OPEN PANEL The indoor unit s Open Panel can be removed for easy cleaning and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easier care SUPER QUIET OPERATION When the FAN button is used to select QUIET the unit begins super quiet operation the indoor unit s airflow is reduced to produce quieter operation POLY...

Page 4: ...ig 4 To facilitate explanation the accompanying illustra tion has been drawn to show all possible indicators in actral operation however the display will only show those indicators appropriate to the current operation Fig 7 Fig 6 ...

Page 5: ... Display Timer Mode Display Fan Speed Display Temperature SET Display a SLEEP Display b SWING Display Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the...

Page 6: ...ters When a signal is properly received by the air conditioner a beeping sound will be heard If no beep is heard press the Remote Controller button again Remote Controller Holder PREPARATION CAUTION Take care to prevent infants from acciden tally swallowing batteries When not using the Remote Controller for an extended period remove the batteries to avoid possible leakage and damage to the unit If...

Page 7: ... actual room temperature To Set the Fan Speed Press the FAN button Fig 6 P Each time the button is pressed the fan speed changes in the following order X X X X X MED AUTO HIGH LOW QUIET About three seconds later the entire display will reappear When set to AUTO Cooling As the room temperature approaches that of the temperature setting the fan speed becomes slower Fan The fan runs at the low fan sp...

Page 8: ...djust the temperature to the value set in the temperature set ting If the mode automatically selected by the unit is not what you wish select one of the mode operation COOL DRY FAN About Mode Operation Cooling Use to cool your room Dry Use for gently cooling while dehumidifying your room You cannot heat the room during Dry mode During Dry mode the unit will operate at low speed in order to adjust ...

Page 9: ... the desired mode and times About three seconds later the entire display will reappear The indoor unit s TIMER Indicator Lamp green Fig 3 6 will light 3 Press the TIMER MODE button Fig 6 N to select the PROGRAM timer operation OFF ON or OFF ON will display The display will alternately show OFF timer and ON timer then change to show the time setting for the operation to occur first The program time...

Page 10: ...ng during sleep the SLEEP timer function automatically modifies the temperature setting in accordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the temperature setting is automatically raised 1 C every sixty minutes When the temperature has been raised a total of 2 C the temperature setting ...

Page 11: ...es they will be automatically returned to the 3 range When used in a room with infants children elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 6 R Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air flow Directio...

Page 12: ...ding to the current airflow direction Airflow direction is 1 4 for cooling dry With the upper airflow direction louver in the horizon tal position the lower airflow direction louver moves swings to direct airflow to a wide area Left right swing The airflow direction louvers move swing in the left right airflow direction Up down left right swing The airflow direction louvers move swing in both the ...

Page 13: ...ace 3 Replace the Air Filter and close the Intake Grille 1 Align the sides of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by wash...

Page 14: ... for installation of the air cleaning filter set 3 Install the two Air filters and close the Intake Grille Air Filter Right Left In regard to the Air Cleaning Filters POLYPHENOL CATECHIN AIR CLEANING FILTER one sheet The Air Cleaning Filters are disposable filters They can not be washed and reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has bee...

Page 15: ...ise is heard During operation and immediately after stopping the unit the sound of water flowing in the air conditioner s piping may be heard Also noise may be particularly noticeable for about 2 to 3 minutes after starting operation sound of coolant flowing During operation a slight squeaking sound may be heard This is the result of minute expansion and contraction of the front cover due to tempe...

Page 16: ...r etc or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction In this event temporarily discon nect the Power Supply Plug reconnect it and then use the Remote Controller to resume operation Symptom Items to check See Page CHECK ONCE MORE Doesn t operate at all Is the Power Supply Plug disconnected its outlet Has there been a power failure Has a fuse blown out or ...

Page 17: ...unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip onto the floor or other objects underneath About 80 or more If the outdoor temperature is lower than the temperature scope in the list above in order to keep...

Page 18: ......

Page 19: ......

Page 20: ......

Reviews: