SAFETY DEVICES
10.
Protection form
Model
AOTG18KMCA
AOTG22KMCA
AOTG24KMCA
Circuit protection
Current fuse
(Near the terminal)
-
Current fuse
(Main PC board)
250 V 25 A
250 V 5 A
Fan motor protection
Thermal protection program
OFF: 100 ± 15 °C
ON: 95 ± 10 °C
Compressor protection
Thermal protection program
(Discharge temp.)
OFF: 110 °C
ON: After 7 minutes
Thermal protection
Thermal protection fuse
(Terminal)
1 A 70 °C