background image

13

TROUBLESHOOTING

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec-
trical breaker or disconnect the power supply plug, and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power
source. Always be sure to turn off the electrical breaker or disconnect the power supply plug to
ensure that power is completely off.

Before requesting service, perform the following checks:

WARNING!

Symptom

Doesn’t operate immedi-
ately:

Noise is heard:

Smells:

Mist or steam are
emitted:

Airflow is weak or stops:

Water is produced from
the outdoor unit:

Problem

If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.

Whenever the electrical breaker is turned off then on again or the
power supply plug is disconnected and then reconnected, the pro-
tection circuit will operate for about 3 minutes, preventing unit
operation during that period.

During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioner’s piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).

During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front cover
due to temperature changes.

During Heating operation, a sizzling sound may be heard occa-
sional. This sound is produced by the Automatic Defrosting op-
eration.

Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.

During Cooling or Dry operation, a thin mist may be seen emitted
from the indoor unit. This results from the sudden Cooling of
room air by the air emitted from the air conditioner, resulting in
condensation and misting.

During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to Automatic
Defrosting operation.

When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.

During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat for a higher setting.

During Heating operation, the unit will temporarily stop opera-
tion (between 7 and 15 minutes) as the Automatic Defrosting mode
operates. During Automatic Defrosting operation, the OPERATION
indicator lamp will flash.

The fan may operate at very low speed during Dry operation or
when the unit is monitoring the room’s temperature.

In the monitor AUTO operation, the fan will operate at very low
speed.

During Heating operation, water may be produced from the out-
door unit due to Automatic Defrosting operation.

See Page

14

14

14

6

6

14

NORMAL

FUNCTION

Summary of Contents for AOT24PMAL

Page 1: ...OOM AIR CONDITIONER WALL MOUNTED TYPE KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED OPERATING MANUAL Indoor Unit AST24PBA AST30PBA Outdoor Unit AOT24PMAL AOT30PMAL P N9370143010 ...

Page 2: ...damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure that any e...

Page 3: ...ONAL AIR FLOW SWING OPERATION Three dimensional control over air direction swing is possi ble through dual use of both an UP DOWN air direction swing and RIGHT LEFT air direction swing Since UP DOWN air direction flaps operate automatically according to the oper ating mode of the unit it is possible to set air direction based on the operating mode REMOVABLE INTAKE GRILLE The indoor unit s INTAKE G...

Page 4: ...3 A 0 1 3 9 B C 7 6 5 4 8 2 D SWING SWING TIMER OPERATION G E F Fig 2 Fig 3 Fig 4 NAME OF PARTS Fig 6 Fig 1 Fig 8 Fig 7 Fig 5 G E F ...

Page 5: ... flash simultaneously To stop the test operation mode either press the TEST RUN button once again or press the START STOP button to stop the air conditioner V Remote Control Unit Display Fig 8 W Transmit Indicator X Clock Display Y Operating Mode Display Z Timer Mode Display Fan Speed Display Temperature Set Display Timer Set Indicator Temperature Set Indicator Fig 1 Indoor Unit 1 Operating Contro...

Page 6: ...de to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the SET TIME buttons to adjust the clock to the current time button Press to advance the ...

Page 7: ...nit s display About three seconds later the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear...

Page 8: ...ed to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic De frosting operation the OPERATION indicator lamp red will flash and the heat operation will be interrupted...

Page 9: ... STOP button To Change Operating Conditions If you wish to change the operating conditions Mode Fan Speed Thermostat Setting after making the timer setting wait until the entire display reappears then press the appropriate buttons to change the operating condition desired To Cancel the Timer Use the TIMER button to select TIMER RESET The air conditioner will return to normal operation To Change th...

Page 10: ...on When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When the thermo stat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting 2 C 3 C 4 C 30 minutes 1 C 1 hour 1 hour 30 minutes Set time Set time 1 hour 1 C 2 C U...

Page 11: ...djustments within the ranges shown above Fig 10 ADJUSTING THE DIRECTION OF AIR CIRCULATION Vertical up down direction of airflow is adjusted by pressing the remote control unit s AIR FLOW DIRECTION VERTICAL SET button Horizontal right left direction of airflow is adjusted by pressing the remote control unit s AIR FLOW DIRECTION HORIZONTAL SET button DANGER Never place fingers or foreign objects in...

Page 12: ...he air UP DOWN direction flaps in the range 4 to 6 for long periods of time since water vapor may condense near the outlet port and drops of water may drip from the air conditioner To select Horizontal airflow SWING Operation Press the AIR FLOW DIRECTION HORIZONTAL SWING button The SWING indicator lamp HORIZONTAL SWING will light In this mode the RIGHT LEFT air direction louvers will swing automat...

Page 13: ...he intake grille fully to remove 2 Clean with water Remove dust with a vacuum cleaner wipe the unit with warm water then dry with a clean soft cloth 3 Replace the intake grille 1 Holding the intake grille horizontally fasten the two upper hooks on the unit 2 Press the intake grille down at the lower sides to close Intake Grille Air filter handle Hooks two places Intake Grille Hooks two places Befo...

Page 14: ...of the front cover due to temperature changes During Heating operation a sizzling sound may be heard occa sional This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from ...

Page 15: ...ciple absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we recom mend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughou...

Page 16: ... long peri ods under high humidity condi tions condensation may form on the surface of the indoor unit and drip onto the floor or other objects underneath Outdoor temperature Indoor temperature Indoor humidity Cooling Mode About 0 to 43 C About 18 to 32 C About 80 or less If the unit is used for long peri ods under high humidity condi tions condensation may form on the surface of the indoor unit a...

Page 17: ... 3 300 600 3 950 CURRENT A 11 0 2 8 14 0 13 8 2 8 16 5 ENERGY EFFICIENCY RATIO 2 70 2 42 HEATING CAPACITY W 8 500 1 400 9 500 9 500 1 400 10 200 POWER INPUT W 2 740 500 3 350 3 320 500 3 950 CURRENT A 11 5 2 3 14 0 13 9 2 3 16 5 MAX PRESSURE MPa 2 7 REFRIGERANT R22 g 2 200 DIMENSIONS WEIGHT NET INDOOR UNIT HEIGHT 320 mm WIDTH 1 120 mm DEPTH 220 mm WEIGHT 16 kg OUTDOOR UNIT HEIGHT 900 mm WIDTH 900 ...