TROUBLESHOOTING

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec-
trical breaker or disconnect the power supply plug, and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power
source. Always be sure to turn off the electrical breaker or disconnect the power supply plug to
ensure that power is completely off.

Before requesting service, perform the following checks:

WARNING!

Symptom

Doesn’t operate immedi-
ately:

Noise is heard:

Smells:

Mist or steam are
emitted:

Airflow is weak or stops:

Water is produced from
the outdoor unit:

Problem

If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.

Whenever the electrical breaker is turned off then on again or the
power supply plug is disconnected and then reconnected, the pro-
tection circuit will operate for about 3 minutes, preventing unit
operation during that period.

During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioner’s piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).

During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front cover
due to temperature changes.

*

During Heating operation, a sizzling sound may be heard occa-
sionally. This sound is produced by the Automatic Defrosting
operation.

Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.

During Cooling or Dry operation, a thin mist may be seen emitted
from the indoor unit. This results from the sudden Cooling of
room air by the air emitted from the air conditioner, resulting in
condensation and misting.

*

During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to the Auto-
matic Defrosting operation.

*

When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.

*

During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat to a higher setting.

*

During Heating operation, the unit will temporarily stop opera-
tion (between 7 and 15 minutes) as the Automatic Defrosting mode
operates. During the Automatic Defrosting operation, the OPERA-
TION indicator lamp will flash.

The fan may operate at very low speed during Dry operation or
when the unit is monitoring the room’s temperature.

In the monitor AUTO operation, the fan will operate at very low
speed.

*

In case of Multi-type unit, if multiple units are operated in differ-
ent operation modes as shown below, the units operated after-
ward will stop and the OPERATION indicator lamp (red) will flash.
Heating mode and cooling mode (or dry mode)
Heating mode and fan mode

*

During Heating operation, water may be produced from the out-
door unit due to the Automatic Defrosting operation.

See Page

16

16

16

6

6

17

16

NORMAL

FUNCTION

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

Summary of Contents for AOT24LMADL

Page 1: ...P N9373553021 KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED OPERATING MANUAL ROOM AIR CONDITIONER Indoor Unit AST18 SERIES AST24 SERIES AST30 SERIES ...

Page 2: ... source when not using the unit for extended periods Always turn off the electrical breaker or disconnect the power supply plug whenever cleaning the air conditioner or the air filter Connection valves become hot during Heating handle with care Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained f...

Page 3: ...hed the unit automatically turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation OMNI DIRECTIONAL AIR FLOW SWING OPERATION Three dimensional control over air direction swing is possi ble through dual use of both an UP DOWN air direction swing and RIGHT LEFT air direction swing Since UP DOWN air direction flaps operate automat...

Page 4: ...3 A 0 1 3 9 B C 7 6 5 4 8 2 D SWING SWING TIMER OPERATION Fig 2 Fig 3 Fig 4 NAME OF PARTS Fig 1 Fig 5 Fig 7 Fig 6 HEAT COOL MODEL REVERSE CYCLE COOLING MODEL ...

Page 5: ...Transmitter I TIMER button J FAN CONTROL button K START STOP button L AIR FLOW DIRECTION VERTICAL SET button M AIR FLOW DIRECTION VERTICAL SWING button N AIR FLOW DIRECTION HORIZONTAL SET button O AIR FLOW DIRECTION HORIZONTAL SWING button P TIME ADJUST button Q ACL button Rear side Fig 6 R TEST RUN Touch the two metal contacts with a me tallic object to send the signal to perform a test run Perfo...

Page 6: ...is properly received by the air conditioner a beeping sound will be heard If no beep is heard press the remote control unit button again Remote Control Unit Holder 3 To remove the Remote Control Unit when use at hand 1 Mount the Holder 2 Set the Remote Control Unit Screws Insert Press in Slide up Pull out CAUTION Take care to prevent infants from accidentally swallowing batteries When not using th...

Page 7: ...emperature during the FAN mode the temperature will not appear on the remote control unit s display Thermostat setting range COOLING MODEL AUTO 18 to 30 C Cooling Dry 18 to 30 C The thermostat cannot be used to set room temperature during the FAN mode the temperature will not appear on the remote control unit s display About three seconds later the entire display will reappear The thermostat setti...

Page 8: ... The fan will operate at very low setting during Monitor operation and at the start of the Heating mode Fan COOLING MODEL The fan alternately turns on and off when on the fan runs at the low fan speed The fan will operate at a very low setting during Monitor operation When set to Quiet SUPER QUIET operation begins The indoor unit s airflow will be reduced for qui eter operation SUPER QUIET operati...

Page 9: ...OL DRY FAN Heating Use to warm your room When Heating mode is selected the air conditioner will operate at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan set ting This period of time is provided to allow the indoor unit to warm up before beginning full operation When the room temperature is very low frost may form on the outside unit and its performance ...

Page 10: ...peration while the Timer is Operating Press the START STOP button To Change Operating Conditions If you wish to change the operating conditions Mode Fan Speed Thermostat Setting after making the timer setting wait until the entire display reappears then press the appropriate buttons to change the operating condition desired To Cancel the Timer Use the TIMER button to select TIMER RESET The air con...

Page 11: ...tat setting is auto matically raised 1 C every sixty minutes When the thermo stat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting 2 C 3 C 4 C 30 minutes 1 C 1 hour 1 hour 30 minutes Set time Set time 1 hour 1 C 2 C Instructions relating to heating are applic...

Page 12: ...g 9 ADJUSTING THE DIRECTION OF AIR CIRCULATION Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle Vertical up down direction of airflow is adjusted by pressing the remote control unit s AIR FLOW DIRECTION VERTICAL SET button Horizontal right left direction of airflow is adjusted by pressing the remote control unit s AIR FLOW DIRECTION HORIZONTAL SET button DANGER...

Page 13: ...he air UP DOWN direction flaps in the range 4 to 6 for long periods of time since water vapor may condense near the outlet port and drops of water may drip from the air conditioner To select Horizontal airflow SWING Operation Press the AIR FLOW DIRECTION HORIZONTAL SWING button The SWING indicator lamp HORIZONTAL SWING will light In this mode the RIGHT LEFT air direction louvers will swing automat...

Page 14: ...he intake grille fully to remove 2 Clean with water Remove dust with a vacuum cleaner wipe the unit with warm water then dry with a clean soft cloth 3 Replace the intake grille 1 Holding the intake grille horizontally fasten the two upper hooks on the unit 2 Press the intake grille down at the lower sides to close Intake Grille Air filter handle Hooks two places Intake Grille Hooks two places Befo...

Page 15: ...grille and remove the air filters 2 Replace them by two new air cleaning filters 1 Remove the old air cleaning filters in reverse order of their installation 2 Install in the same way as for installation of the air cleaning filter set 3 Install the two air filters and close the intake grille In regard to the Air cleaning filters Air purifying filter green filter Depending on the size of the room a...

Page 16: ...smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensation and misting During Heating operation the outd...

Page 17: ...t the room with the result that some time may be required after first starting the air con ditioner until the room is heated Microcomputer controlled Automatic Defrosting When using the Heating mode under conditions of low out door air temperature high humidity frost may form on the outdoor unit resulting in reduced operating performance In order to prevent this kind of reduced performance this un...

Page 18: ...aneously but when two or more indoor units of the same group are oper ated simultaneously the heating and cooling efficiency will be less than when a single indoor unit is used alone Accordingly when you wish to use more than one in door unit for cooling at the same time the use should be concentrated at night and other times when less out put is required In the same way when multiple units are us...

Page 19: ...dinary dwellings When the outdoor temperature drops the outdoor unit s fans may switch to Low Speed If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip onto the floor or other objects underneath About 80 or more OPERATING TIPS Humidity About 80 or less If the unit is used for long peri ods under high humidity condi ti...

Page 20: ......

Reviews: